Catalog excerpts
KR20 WIRELESS UNIT (AKR2) ■ To prevent from interference with the other wireless station (Japan only) In the frequency band using this unit, in-plant radio station (license is necessary.) using at industrial such as microwave oven, science, medical machinery and a production line in factory to identify mobile object, specified low power radio station (license is not necessary.) and amateur radio station (license is necessary.) are managed 1) Before using this unit, please confirm that in-plant radio station to identify mobile object, specified low power radio station and amateur radio station are not managed. 2) When some cases of harmful electric wave interference occurred from this unit to an in-plant radio station to identify mobile object, change the using frequency immediately or stop discharging the electric wave. After that please contact us to consult measures to avoid interference (for example, setting of partition). 3) When any other troubles such as harmful electric wave interference occurred from this unit to a specified low power radio station or an amateur radio station or an amateur radio station, please contact us. 2.4GHz band electric wave is used. Modulation method is direct sequence type. Intended interference distance is 40m. All bands are used and possible to avoid the band of machine to identify mobile object. High-speed, wireless communication with easy installation and simple wiring!! *Please put the attached label “Caution for using wireless unit” near the setting place. ■ Countries where the use of KR20 has been authorized Products with the indication label affixed to their rear side As of May 2008, the use of KR20 has been authorized in the following countries. Japan, China, 25 European countries (Austria, Belgium, Czech Republic, Denmark, Estonia, Finland, France*, Germany, Greece, Hungary, Iceland, Ireland, Italy, Lithuania, Malta, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland, UK, Netherlands) * In France, this product must not be used outdoors. Please use it indoors only. ■ Compliance for EN standard Obtained the European wireless certification (EN300 328) In order to comply with EN standard, use this product in following condition. • When installing this product to wall, install it on a DIN rail. • Use power supply cord that is less than 3m. • For communication cable (RS232C or RS485), use shielded cable, and connect one end of shield wire to ground. And use ferrite core (correspond to TDK: ZCAT2035-0930) in the communication cable (RS232C or RS485) of wireless unit side. (Turn numbers: 2T) Antenna with cable *Antenna sold separately. Antenna extension cable High-speed data transfer Matsushita Electric Works, Ltd. Antenna with cable available Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan Telephone: +81-6-6908-1050 Facsimile: +81-6-6908-5781 http://www.mew.co.jp/ac/e/ All Rights Reserved © 2008 COPYRIGHT Matsushita Electric Works, Ltd. ARCT1B301E 200805-3YT Specifications are subject to change without notice. Matsushita Electric Works, Ltd.
Open the catalog to page 1Application Examples Optimum for high-speed data communications. Wireless repeater function 134 kbps wireless communication speed optimum for high-speed data communications. Optimum for reducing the wiring and installation work. The communicable distance between the master and a slave is approximately 250 m*1 outdoors*2 or approximately 50 m indoors. The communication distance can be extended using the repeater function incorporated in this unit. (Up to eight repeaters can be installed between the master and slave.) Reduces the cable installation costs when the layout for machines and...
Open the catalog to page 2Application Examples Optimum for high-speed data communications. Wireless repeater function 134 kbps wireless communication speed optimum for high-speed data communications. Optimum for reducing the wiring and installation work. The communicable distance between the master and a slave is approximately 250 m*1 outdoors*2 or approximately 50 m indoors. The communication distance can be extended using the repeater function incorporated in this unit. (Up to eight repeaters can be installed between the master and slave.) Reduces the cable installation costs when the layout for machines and...
Open the catalog to page 33. Serial communication specifications (RS232C) *4 Item 1. Main unit Model number Product name KR20 WIRELESS UNIT RS485 type Transmission distance KR20 WIRELESS UNIT I/O type (NPN) Transmission speed KR20 WIRELESS UNIT I/O type (PNP) Communication method Synchronous system Synchronous communication method Transmission format Stop bit: 1 bit, Parity: Not available/Available (odd/even), Data length: 7bit/8bit Data buffer 2048 bytes (Max. data byte size for send and receive one time) • A power supply cable (1 m) for the main unit is supplied with this product. • Antenna is not attached. Select...
Open the catalog to page 43. Serial communication specifications (RS232C) *4 Item 1. Main unit Model number Product name KR20 WIRELESS UNIT RS485 type Transmission distance KR20 WIRELESS UNIT I/O type (NPN) Transmission speed KR20 WIRELESS UNIT I/O type (PNP) Communication method Synchronous system Synchronous communication method Transmission format Stop bit: 1 bit, Parity: Not available/Available (odd/even), Data length: 7bit/8bit Data buffer 2048 bytes (Max. data byte size for send and receive one time) • A power supply cable (1 m) for the main unit is supplied with this product. • Antenna is not attached. Select...
Open the catalog to page 5■ Part Name and Dimensions (Unit: mm) Main unit 1) When mounting, (wiring, adjustment etc.), be careful not to add static electricity to connector, switch and antenna. 2) Do not squeeze the switches or push buttons with an excessive force. Otherwise, they may be damaged. With standard antenna Antenna mounting section Communication channel switch MODE switch ENTER switch Four LED displays DIN hook 3.5 Cover 25 DIN rail attachment gap (35 mm width) Power supply connector RS232C Power supply connector RS232C Operating mode switch 110±0.5 1) Do not place the units in the vicinity of radios or...
Open the catalog to page 6All Panasonic Electric Works Europe catalogs and technical brochures
-
FM-200
12 Pages
-
Automation Controls Catalog
14 Pages
-
FPWIN Pro
8 Pages
-
Automation Controls Catalog
14 Pages
-
GX-F/H SERIES
16 Pages
-
FOR SENSORS PRODUCT FINDER
2 Pages
-
Short form SENSORS
124 Pages
-
Programmable Logic Controllers
32 Pages
-
IONIZER
36 Pages
-
PhotoMOS Catalog
354 Pages
-
Catalog Automotive Relays
210 Pages
-
AC Servo
155 Pages
-
Sensor short form
132 Pages
-
MINAS A5 SERVO DRIVES
28 Pages
-
HIGHLIGHTS FOR ECO INNOVATIONS
12 Pages
-
Catalogue-connectors
158 Pages
-
Fire alarm systems 2013
28 Pages
-
Shortform Temperature Controller
28 Pages
-
ELECTROMECHANICAL RELAYS
626 Pages
-
EY 7443 Auto Drill & Driver
2 Pages
-
Sealing Guns 2012/2013
8 Pages
-
New Products Autumn 2012
20 Pages
-
Catalog MINAS A5 series
85 Pages
-
FP-Safe catalog
12 Pages
-
Overview HMI
36 Pages
-
Overview Eco-POWER METERs
20 Pages
-
Panasonic Automation Products
28 Pages
-
Catalog built-in sensors
66 Pages
-
Catalog Microwave Devices
69 Pages
-
LC4H - digital counter
9 Pages
-
Limit switches AZH
14 Pages
-
Fire alarm system 2011/2012
28 Pages
-
Imagechecker P400XD
20 Pages
-
2D Code Reading Sensor PD60 / 65
12 Pages
-
FP-e: PLC for panel mounting
8 Pages
-
UJ30/35
12 Pages
-
GN-series touch terminals
36 Pages
-
Eco-power meters
16 Pages
-
Laser markers
28 Pages
-
Catalog timers & counters
160 Pages
-
Catalog limit switches
52 Pages
-
PHOTOMOS & SOLID STATE RELAYS
356 Pages
-
Catalog Switches
186 Pages
Archived catalogs
-
P400MA and P400 Imagecheckers
20 Pages
-
Turquoise switch series
28 Pages
-
Catalogue operation switches
156 Pages
-
R-1755 R-1650
2 Pages
-
Laserdrillable Prepreg
1 Pages
-
R-1566W R-1551W
1 Pages
-
MC-100EX/MS
1 Pages
-
Base 2324
2 Pages
-
Heat detectors 4375 and 4376
2 Pages
-
Multi detector 4350
2 Pages
-
Addressable siren 3377
2 Pages
-
External power supply 3366
2 Pages
-
Analog base 3312F / FL
2 Pages
-
Analog base 3312
2 Pages
-
Analog multi detector 4300
2 Pages
-
Analog heat detector 3308
2 Pages
-
Fire alarm system EBL128
2 Pages
-
Fire alarm system EBL512
2 Pages
-
Dicool
24 Pages
-
Eco-POWER METER KW4S
6 Pages
-
KW4M Eco-POWER METER
4 Pages
-
KW8M Eco-POWER METER
8 Pages
-
S1DX – analog timer
6 Pages
-
PM4H-W - analog timer - twin
5 Pages
-
PM4H - analog timer
6 Pages
-
PM5S - analog DIN-rail timer
7 Pages
-
QM4H - digital timer
4 Pages
-
LT4H-W
8 Pages
-
LT4H - digital timer
6 Pages
-
KR20 Wireless Unit
8 Pages
-
PV500 Imagechecker
20 Pages
-
Micro-Imagechecker AX30/AX40
16 Pages
-
PV310 Micro-Imagechecker
12 Pages
-
LightPix AE20
4 Pages
-
PD60/65 2D Code Readers
6 Pages
-
Panasonic Automation Products
12 Pages
-
Push Button Switches - ND Series
41 Pages
-
Push Button Switches - NS Series
11 Pages
-
AJ9 (J9) SWITCHES
6 Pages
-
AJ7 (J7) SWITCHES
8 Pages
-
AJ4 (J4) TOGGLE SWITCHES
6 Pages
-
TURQUOISE SNAP SWITCHES (AJN1/2)
10 Pages
-
Catalogue snap action relays
124 Pages
-
Electromechanical Relays
571 Pages
-
P400 and P400S
20 Pages
-
Micro-Imagechecker AX40
16 Pages
-
Brochure "2D Code Reader PD50"
12 Pages
-
A-Series
6 Pages
-
Brochure "LightPix AE20"
4 Pages
-
Imagechecker Brochure
32 Pages
-
Easy User Guide 'Matching'
5 Pages