IONIZER
36Pages

{{requestButtons}}

Catalog excerpts

IONIZER - 2

Product range and typical applications Prevent discharge Freely selectable Surface potential Reduced charge Fast charge removal for measurement during removal time by using wide areas board LEDs charge removal air combined with massive ion discharge Service has priority We are constantly striving to optimize our service to enable us to find numerous illustrations of possible applications. Of course, react quickly to customer requests. Whether you have specific detailed data sheets are available for download on our website application requests or simply want technical information, we...

Open the catalog to page 2
IONIZER - 3

ER-Q. Miniature ionizer with fan . . . . . . . . . . . . . . . . . . . . .6 ER-F. Fan-type ionizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 ER-X. Area ionizer for fast applications . . . . . . . . . . . . . 10 ER-TF. Wide-area ionizer . . . . . . . . . . . . . . . . . . . . . . . . . 16 ER-VW. Ionizer with adjustable nozzle angles . . . . . . . . . . 20 ER-V. Ultra compact high-performance ionizer . . . . . . . 24 EC-G. Pulse air-gun ionizer . . . . . . . . . . . . . . . . . . . . . . . 32 EF-S1. Constant monitoring of static charges on production lines . . . . . . . . . ....

Open the catalog to page 3
IONIZER - 4

Removing static electricity during loading / unloading Removing dust from connectors and switches Eliminating static electricity after circuit board cleaning Preventing jamming in part feeders Removing static electricity during background sheet separation Eliminating static electricity when transporting circuit boards Preventing electrostatic damage to camera module elements Eliminating static electricity during IC tray stacking Eliminating static electricity during loading of circuit boards into in-circuit testers Removing dust while separating TAB protective film Preventing electrostatic...

Open the catalog to page 4
IONIZER - 5

^ Dealing with foreign matter when _applying films_ Preventing jamming of packaging material Preventing adhesion of molded _parts to molds_ f Eliminating static electricity when ^ transporting glass circuit boards Eliminating static electricity when lifting glass sheets Eliminating static electricity when separating protective tape Removing dust during lens assembly Removing dust during transport of cups for food products

Open the catalog to page 5
IONIZER - 6

ER-Q Miniature ionizer with fan Features ■ Small dimensions Simple and space-saving installation on production lines and manual workstations. ■ Adjustable The production of the required air volume can be adjusted any time during operation. ■ Simple maintenance Assembled and disassembled in a single touch, reducing steps required to replace parts or clean filters. ■ Unit for demanding industrial environments The LED displays the required maintenance steps or failures; this also can be queried via PLC. Parts for maintenance are easy to get at and replace. ■ Freely mounted: No air hoses...

Open the catalog to page 6
IONIZER - 7

Note: Typical value at 100mm from directly in front of air outlet, fan speed MAX, with no filter installed. > 0.13mm2 8-core connector cab tire cable > Cable outer diameter: 03.7mm ER-QMS1 /Mounting bracket The ER-Q mounting bracket. Adjust the air output direction. ER-QCC2 / Connector-attached cable Length 2m ER-QCC5/ Connector-attached cable Length 5m ER-QFX5 / Air filter Fan intake filter (5 pcs. per set) ER-QANT / Discharge needle unit Unit with tungsten needles (1 pc.) ■ DIMENSIONS (Unit: mm) ■ CHARGE REMOVAL CHARACTERISTICS (TYPICAL) Ionizer main unit Measured at center of a 150 x...

Open the catalog to page 7
IONIZER - 8

The low volume fan type of the ER-F series generates only half the air volume of the standard type, which is required for small components and thin film. Four different speeds can be selected for the fan. Because the discharge needle unit is attached to the louver, exchange or maintenance of the needles is made easy without touching the main unit. A safe design: once the louver is removed, the high-voltage circuit is broken and the fan halts. Simply replace the louver to change configuration between long distance and wide area ionization. The two louvers come with the ionizer main body....

Open the catalog to page 8
IONIZER - 9

Notes: 1) Typical value at 200mm from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. 2) Typical value at 300mm from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. 3) The discharge needle unit is loaded on the straight louver before shipment. ■ OPTIONS ER-F12ANT / Discharge needle unit Unit with tungsten needles (1 pc.) ER-F12FX5 / Air filter Replacement filter (5 pcs. per set) ■ CHARGE REMOVAL CHARACTERISTICS (TYPICAL) Measured at center of a 150 x 150mm charge plate monitor. * Solid lines in the graphs...

Open the catalog to page 9
IONIZER - 10

ER-X Area ionizer for fast applications Features ■■ Quick charge removal Thanks to the pulse AC method, the ER-X series is well suited for high-speed applications as found in the packaging and semiconductor industries, where charge removal time is directly linked to productivity. In addition, discharge frequencies can be adjusted from between 1 and 100Hz, maximizing flexibility. Thanks to a built-in feedback system, the ionizer can even adjust the discharge frequency automatically during operation. The area ionizer of the ER-X series can be operated with or without air pressure. This...

Open the catalog to page 10
IONIZER - 11

Heads Head connection cable is not supplied with the head. Please order it separately. Power cable > ER-XCCQ Discharge needle unit > ER-XANT

Open the catalog to page 11
IONIZER - 12

ER-X■ SPECIFICATIONSHeads Model No. Notes: 1) The following conditions apply: discharge distance 100mm, center of the product, discharge wavelength 50Hz and no air supply. 2) Ion balance is average of plus and minus. Also, the specification value is typical value in condition of max. ±10°C ambient temperature change, set the ion balance after 30 minutes of the discharge starting, switching on the ion balance control function. 3) The dried clean air is defined for air passing through air dryer (dew point: equivalent of -20°C) and air filter (mesh-size: equivalent of 0.01pm)

Open the catalog to page 12
IONIZER - 13

■■ CHARGE REMOVAL CHARACTERISTICS (TYPICAL) Measured at center of a 150 x 150mm charge plate monitor. Please contact our office for details on data that is not listed here. Charge removal distance L (mm) Charge removal distance L (mm) Correlation between charge removal distance and charge removal time (1Hz) Charge removal time (s) Charge removal time (s) Correlation between charge removal distance and charge removal time (10Hz) Charge removal time (s) Correlation between charge removal distance and charge removal time (50Hz) Charge removal distance L (mm) Charge removal distance L (mm)...

Open the catalog to page 13

All Panasonic Electric Works Europe catalogs and technical brochures

  1. FM-200

    12 Pages

  2. FPWIN Pro

    8 Pages

  3. GX-F/H SERIES

    16 Pages

  4. AC Servo

    155 Pages

  5. Overview HMI

    36 Pages

  6. UJ30/35

    12 Pages

  7. Laser markers

    28 Pages

Archived catalogs

  1. MC-100EX/MS

    1 Pages

  2. Base 2324

    2 Pages

  3. Dicool

    24 Pages

  4. LT4H-W

    8 Pages

  5. P400 and P400S

    20 Pages

  6. A-Series