Product range and typical applications Prevent discharge Freely selectable Surface potential Reduced charge Fast charge removal for measurement during removal time by using wide areas board LEDs charge removal air combined with massive ion discharge Service has priority We are constantly striving to optimize our service to enable us to find numerous illustrations of possible applications. Of course, react quickly to customer requests. Whether you have specific detailed data sheets are available for download on our website application requests or simply want technical information, we...
Open the catalog to page 2ER-Q. Miniature ionizer with fan . . . . . . . . . . . . . . . . . . . . .6 ER-F. Fan-type ionizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 ER-X. Area ionizer for fast applications . . . . . . . . . . . . . 10 ER-TF. Wide-area ionizer . . . . . . . . . . . . . . . . . . . . . . . . . 16 ER-VW. Ionizer with adjustable nozzle angles . . . . . . . . . . 20 ER-V. Ultra compact high-performance ionizer . . . . . . . 24 EC-G. Pulse air-gun ionizer . . . . . . . . . . . . . . . . . . . . . . . 32 EF-S1. Constant monitoring of static charges on production lines . . . . . . . . . ....
Open the catalog to page 3Removing static electricity during loading / unloading Removing dust from connectors and switches Eliminating static electricity after circuit board cleaning Preventing jamming in part feeders Removing static electricity during background sheet separation Eliminating static electricity when transporting circuit boards Preventing electrostatic damage to camera module elements Eliminating static electricity during IC tray stacking Eliminating static electricity during loading of circuit boards into in-circuit testers Removing dust while separating TAB protective film Preventing electrostatic...
Open the catalog to page 4^ Dealing with foreign matter when _applying films_ Preventing jamming of packaging material Preventing adhesion of molded _parts to molds_ f Eliminating static electricity when ^ transporting glass circuit boards Eliminating static electricity when lifting glass sheets Eliminating static electricity when separating protective tape Removing dust during lens assembly Removing dust during transport of cups for food products
Open the catalog to page 5ER-Q Miniature ionizer with fan Features ■ Small dimensions Simple and space-saving installation on production lines and manual workstations. ■ Adjustable The production of the required air volume can be adjusted any time during operation. ■ Simple maintenance Assembled and disassembled in a single touch, reducing steps required to replace parts or clean filters. ■ Unit for demanding industrial environments The LED displays the required maintenance steps or failures; this also can be queried via PLC. Parts for maintenance are easy to get at and replace. ■ Freely mounted: No air hoses...
Open the catalog to page 6Note: Typical value at 100mm from directly in front of air outlet, fan speed MAX, with no filter installed. > 0.13mm2 8-core connector cab tire cable > Cable outer diameter: 03.7mm ER-QMS1 /Mounting bracket The ER-Q mounting bracket. Adjust the air output direction. ER-QCC2 / Connector-attached cable Length 2m ER-QCC5/ Connector-attached cable Length 5m ER-QFX5 / Air filter Fan intake filter (5 pcs. per set) ER-QANT / Discharge needle unit Unit with tungsten needles (1 pc.) ■ DIMENSIONS (Unit: mm) ■ CHARGE REMOVAL CHARACTERISTICS (TYPICAL) Ionizer main unit Measured at center of a 150 x...
Open the catalog to page 7The low volume fan type of the ER-F series generates only half the air volume of the standard type, which is required for small components and thin film. Four different speeds can be selected for the fan. Because the discharge needle unit is attached to the louver, exchange or maintenance of the needles is made easy without touching the main unit. A safe design: once the louver is removed, the high-voltage circuit is broken and the fan halts. Simply replace the louver to change configuration between long distance and wide area ionization. The two louvers come with the ionizer main body....
Open the catalog to page 8Notes: 1) Typical value at 200mm from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. 2) Typical value at 300mm from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. 3) The discharge needle unit is loaded on the straight louver before shipment. ■ OPTIONS ER-F12ANT / Discharge needle unit Unit with tungsten needles (1 pc.) ER-F12FX5 / Air filter Replacement filter (5 pcs. per set) ■ CHARGE REMOVAL CHARACTERISTICS (TYPICAL) Measured at center of a 150 x 150mm charge plate monitor. * Solid lines in the graphs...
Open the catalog to page 9ER-X Area ionizer for fast applications Features ■■ Quick charge removal Thanks to the pulse AC method, the ER-X series is well suited for high-speed applications as found in the packaging and semiconductor industries, where charge removal time is directly linked to productivity. In addition, discharge frequencies can be adjusted from between 1 and 100Hz, maximizing flexibility. Thanks to a built-in feedback system, the ionizer can even adjust the discharge frequency automatically during operation. The area ionizer of the ER-X series can be operated with or without air pressure. This...
Open the catalog to page 10Heads Head connection cable is not supplied with the head. Please order it separately. Power cable > ER-XCCQ Discharge needle unit > ER-XANT
Open the catalog to page 11ER-X■ SPECIFICATIONSHeads Model No. Notes: 1) The following conditions apply: discharge distance 100mm, center of the product, discharge wavelength 50Hz and no air supply. 2) Ion balance is average of plus and minus. Also, the specification value is typical value in condition of max. ±10°C ambient temperature change, set the ion balance after 30 minutes of the discharge starting, switching on the ion balance control function. 3) The dried clean air is defined for air passing through air dryer (dew point: equivalent of -20°C) and air filter (mesh-size: equivalent of 0.01pm)
Open the catalog to page 12■■ CHARGE REMOVAL CHARACTERISTICS (TYPICAL) Measured at center of a 150 x 150mm charge plate monitor. Please contact our office for details on data that is not listed here. Charge removal distance L (mm) Charge removal distance L (mm) Correlation between charge removal distance and charge removal time (1Hz) Charge removal time (s) Charge removal time (s) Correlation between charge removal distance and charge removal time (10Hz) Charge removal time (s) Correlation between charge removal distance and charge removal time (50Hz) Charge removal distance L (mm) Charge removal distance L (mm)...
Open the catalog to page 13All Panasonic Electric Works Europe catalogs and technical brochures
-
FM-200
12 Pages
-
Automation Controls Catalog
14 Pages
-
FPWIN Pro
8 Pages
-
Automation Controls Catalog
14 Pages
-
GX-F/H SERIES
16 Pages
-
FOR SENSORS PRODUCT FINDER
2 Pages
-
Short form SENSORS
124 Pages
-
Programmable Logic Controllers
32 Pages
-
PhotoMOS Catalog
354 Pages
-
Catalog Automotive Relays
210 Pages
-
AC Servo
155 Pages
-
Sensor short form
132 Pages
-
MINAS A5 SERVO DRIVES
28 Pages
-
HIGHLIGHTS FOR ECO INNOVATIONS
12 Pages
-
Catalogue-connectors
158 Pages
-
Fire alarm systems 2013
28 Pages
-
Shortform Temperature Controller
28 Pages
-
ELECTROMECHANICAL RELAYS
626 Pages
-
EY 7443 Auto Drill & Driver
2 Pages
-
Sealing Guns 2012/2013
8 Pages
-
New Products Autumn 2012
20 Pages
-
Catalog MINAS A5 series
85 Pages
-
FP-Safe catalog
12 Pages
-
Overview HMI
36 Pages
-
Overview Eco-POWER METERs
20 Pages
-
Panasonic Automation Products
28 Pages
-
Catalog built-in sensors
66 Pages
-
Catalog Microwave Devices
69 Pages
-
LC4H - digital counter
9 Pages
-
Limit switches AZH
14 Pages
-
Fire alarm system 2011/2012
28 Pages
-
Imagechecker P400XD
20 Pages
-
2D Code Reading Sensor PD60 / 65
12 Pages
-
FP-e: PLC for panel mounting
8 Pages
-
UJ30/35
12 Pages
-
GN-series touch terminals
36 Pages
-
Eco-power meters
16 Pages
-
Laser markers
28 Pages
-
Catalog timers & counters
160 Pages
-
Catalog limit switches
52 Pages
-
PHOTOMOS & SOLID STATE RELAYS
356 Pages
-
Catalog Switches
186 Pages
Archived catalogs
-
P400MA and P400 Imagecheckers
20 Pages
-
Turquoise switch series
28 Pages
-
Catalogue operation switches
156 Pages
-
R-1755 R-1650
2 Pages
-
Laserdrillable Prepreg
1 Pages
-
R-1566W R-1551W
1 Pages
-
MC-100EX/MS
1 Pages
-
Base 2324
2 Pages
-
Heat detectors 4375 and 4376
2 Pages
-
Multi detector 4350
2 Pages
-
Addressable siren 3377
2 Pages
-
External power supply 3366
2 Pages
-
Analog base 3312F / FL
2 Pages
-
Analog base 3312
2 Pages
-
Analog multi detector 4300
2 Pages
-
Analog heat detector 3308
2 Pages
-
Fire alarm system EBL128
2 Pages
-
Fire alarm system EBL512
2 Pages
-
Dicool
24 Pages
-
Eco-POWER METER KW4S
6 Pages
-
KW4M Eco-POWER METER
4 Pages
-
KW8M Eco-POWER METER
8 Pages
-
S1DX – analog timer
6 Pages
-
PM4H-W - analog timer - twin
5 Pages
-
PM4H - analog timer
6 Pages
-
PM5S - analog DIN-rail timer
7 Pages
-
QM4H - digital timer
4 Pages
-
LT4H-W
8 Pages
-
LT4H - digital timer
6 Pages
-
KR20 Wireless Unit
8 Pages
-
PV500 Imagechecker
20 Pages
-
Micro-Imagechecker AX30/AX40
16 Pages
-
PV310 Micro-Imagechecker
12 Pages
-
LightPix AE20
4 Pages
-
PD60/65 2D Code Readers
6 Pages
-
Panasonic Automation Products
12 Pages
-
Push Button Switches - ND Series
41 Pages
-
Push Button Switches - NS Series
11 Pages
-
AJ9 (J9) SWITCHES
6 Pages
-
AJ7 (J7) SWITCHES
8 Pages
-
AJ4 (J4) TOGGLE SWITCHES
6 Pages
-
TURQUOISE SNAP SWITCHES (AJN1/2)
10 Pages
-
Catalogue snap action relays
124 Pages
-
Electromechanical Relays
571 Pages
-
P400 and P400S
20 Pages
-
Micro-Imagechecker AX40
16 Pages
-
Brochure "2D Code Reader PD50"
12 Pages
-
A-Series
6 Pages
-
Brochure "LightPix AE20"
4 Pages
-
Imagechecker Brochure
32 Pages
-
Easy User Guide 'Matching'
5 Pages