GX-F/H SERIES
16Pages

{{requestButtons}}

Catalog excerpts

GX-F/H SERIES - 1

Rectangular-shaped Inductive Proximity Sensor GX-F/H SERIES Related Information Amplifier Built-in LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS panasonic-electric-works.net/sunx SUNX website http://www.sunx.com MEASUREMENT SENSORS PNP output Oil resistant type available Different freq. type available STATIC CONTROL DEVICES LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS Industry No. 1* in stable sensing This sensor has the longest stable sensing range among the same level of rectangular inductive proximity sensors in the industry. It is easy to install the sensor. Maximum operation distance Stable sensing range MACHINE VISION SYSTEMS Previous model Stable sensing range Maximum operation distance GX-F/H series Previous model GX-F/H series Selection Guide Amplifier Built-in Amplifierseparated * ased on research conducted by Panasonic Electric Works SUNX B as of August 2010 among equivalent rectangular inductive sensors. Can be installed with ample space Long sensing range * With standard sensing object Variation at the maximum operation distance is within ±8 % Temperature characteristics vary within ±8 % Thorough adjustment and control of sensing sensitivity greatly reduces individual sensor differences and variations. The work of adjusting sensor positions when using multiple sensors and when sensors have been replaced is much easier. Components such as the sensor coil and core and product design have been totally revised to provide excellent temperature characteristics. Stable sensing can be obtained regardless of the time of day or the yearly season. Standard sensing object 60% less Operation distance variation: 0.4 mm 0.016 in or less* For the GX- 8 Maximum operation distance: 2.5 mm 0.098 in ± 8 % (2.3 to 2.7 mm 0.091 to 0.106 in) Operation distance variation: 1.0 mm 0.039 in or less Standard sensing object Maximum operation distance: 2.5 mm 0.098 in ± 20 % (2.0 to 3.0 mm 0.079 to 0.118 in) * Not including temperature characteristics. Image Previous model Rate of variation in sensing range [%] GX-F/H series Previous models Sensing range within temperatures of –25 to +70 °C (–13 to +158 °F) are within ±8 % of the range at +23 °C (+73 °F) Previous models: within +15 % –10

Open the catalog to page 1
GX-F/H SERIES - 2

Rectangular-shaped Inductive Proximity Sensor GX-F/H SERIES Muting control of light curtains Positioning processing equipment Positioning metal pallets LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS ENVIRONMENTAL RESISTANCE SENSOR OPTIONS 10 times the durability! (Compared to previous models) The new integrated construction method used provides shock resistance of 10,000 m/s2 (approx. 1,000 G in X, Y and Z directions for three times each), and vibration resistance clears...

Open the catalog to page 2
GX-F/H SERIES - 3

Rectangular-shaped Inductive Proximity Sensor ORDER GUIDE FIBER SENSORS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS SENSOR OPTIONS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS Sensing range (Note 1) Front sensing LIGHT CURTAINS AREA SENSORS MICRO PHOTOELECTRIC SENSORS Front sensing PHOTOELECTRIC SENSORS LASER SENSORS GX-F/H SERIES Maximum operation distance 1.6 mm 0.063 in (0 to 1.3 mm 0 to 0.051 in) Normally closed NPN open-collector transistor Normally open Normally closed Normally open...

Open the catalog to page 3
GX-F/H SERIES - 4

Rectangular-shaped Inductive Proximity Sensor GX-F/H SERIES ORDER GUIDE FIBER SENSORS LASER SENSORS Front sensing Top sensing Front sensing Sensing range (Note 1) Maximum operation distance 4.0 mm 0.157 in (0 to 3.3 mm 0 to 0.130 in) Stable sensing range Front sensing Top sensing Front sensing PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Normally open Normally closed MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS INDUCTIVE PROXIMITY SENSORS Normally closed PRESSURE / FLOW SENSORS Normally open AREA SENSORS LIGHT...

Open the catalog to page 4
GX-F/H SERIES - 5

Rectangular-shaped Inductive Proximity Sensor ORDER GUIDE FIBER SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS AREA SENSORS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS SENSOR OPTIONS Front sensing MICRO PHOTOELECTRIC SENSORS GX-15 (Long sensing range) type Front sensing PHOTOELECTRIC SENSORS LASER SENSORS GX-F/H SERIES Sensing range (Note 1) Maximum operation...

Open the catalog to page 5
GX-F/H SERIES - 6

Rectangular-shaped Inductive Proximity Sensor GX-F/H SERIES FIBER SENSORS LASER SENSORS GX-6 type Model No. (Note 2) Type Item PHOTOELECTRIC SENSORS Front sensing Max. operation distance (Note 3) Stable sensing range (Note 3) Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.0016 in or less INDUCTIVE PROXIMITY SENSORS Supply voltage Current consumption AREA SENSORS PRESSURE / FLOW SENSORS 20 % or less of operation distance (with standard sensing object) MICRO PHOTOELECTRIC SENSORS LIGHT CURTAINS Standard sensing object 15 mA or less NPN open-collector transistor PNP...

Open the catalog to page 6
GX-F/H SERIES - 7

Rectangular-shaped Inductive Proximity Sensor FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Type Model No. (Note 2) MICRO PHOTOELECTRIC SENSORS STATIC CONTROL DEVICES HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 20 % or less of operation distance (with standard sensing object) Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.0016 in or less +10 Supply voltage Current consumption 15 mA or less NPN...

Open the catalog to page 7

All Panasonic Electric Works Europe catalogs and technical brochures

  1. FM-200

    12 Pages

  2. FPWIN Pro

    8 Pages

  3. IONIZER

    36 Pages

  4. AC Servo

    155 Pages

  5. Overview HMI

    36 Pages

  6. UJ30/35

    12 Pages

  7. Laser markers

    28 Pages

Archived catalogs

  1. MC-100EX/MS

    1 Pages

  2. Base 2324

    2 Pages

  3. Dicool

    24 Pages

  4. LT4H-W

    8 Pages

  5. P400 and P400S

    20 Pages

  6. A-Series

    6 Pages