External Presentation unit 1728
2Pages

{{requestButtons}}

Catalog excerpts

External Presentation unit 1728 - 1

Panasonic Electric Works Fire & Security Technology Europe AB Citadellsvägen 23, SE-211 18 Malmö, Sweden Tel: +46 (0)40 697 70 00 • Fax: +46 (0)40 697 70 99 info-fste@eu.pewg.panasonic.com • www.panasonic-fire-security.com Fire alarm systems External Presentation unit 1728 • For presentation of pre-warnings, fire alarms, faults & disablements • Compact size Presentation unit 1728 This unit (S/W V1.2) is intended for prewarning, fire and heavy smoke / heat alarm presentation. Point or zone alarm presentation is like in the c.i.e. it is connected to. You can scroll amongst two or more alarms in the system but the fire alarms can not be reset via this unit. All or selected alarms will be presented in a display (LCD, 2x40 characters with backlight). An alarm text will be presented together with each alarm, if programmed in the c.i.e. Furthermore, >617 texts for selected alarms can be stored in the unit and will in such a case be shown, instead of the texts sent from the c.i.e. for these alarms. A built-in buzzer will sound like in the c.i.e. It can be silenced but the alarm devices in the installation can not be silenced via this unit. Any fault in the system will be presented as "General fault in system" and the buzzer will sound. It can be silenced. Any disablement in the system will be presented as "General disablement in system". The unit is power supplied via the c.i.e. or external power supply. LEDs, push buttons etc. The unit has the following LEDs: • Fire (Brand) and Alarms queued (Flera larm), indicating pre-warning, co-incidence and fire alarms. • Operation (Drift), indicating that the unit is connected to a c.i.e. and power supplied, i.e. it is in operation. • Extinguishing (Släckanläggning aktiverad), indicating activated output for extinguishing equipment. • Ventilation (Brandventilation aktiverad), indicating activated output for ventilation equipment. • Fire brigade tx (Larmsändare aktiverad), indicating activated output for Fire brigade tx (routing equipment). The unit has the following push buttons: • Alarms queued (Flera larm), used to scroll amongst the alarms. • Silence buzzer (Summer tyst), used to silence the buzzer (it will re-sound for a new alarm). The designation texts on the front are in 1728SE in Swedish and in 1728UK in English. Compact size The compact size enclosure is made of grey high impact ABS. Fitted with a supplementary "O" ring gasket, it will comply with IP61, in respect of dust and moisture. The push buttons on the front are disabled until they are supposed to be used. The unit shall be wall mounted. Two compression glands are attached. SW mode and address setting The display and the push buttons are used to set the SW mode and address, see the opposite side of this page. Product application The 1728 unit is intended for indoor use and in dry premises. SW mode 1728 - 1587 is intended to be used in the systems EBL512 and EBL128 and SW mode 1728 – 1582 in the systems EBL500 / 512 / 1000 / 2000.

Open the catalog to page 1
External Presentation unit 1728 - 2

All technical features and data are subject to changes without notice, resulting from continuous development and improvement. Product Leaflet Date of issue Revision / Date of revision MEW00280 2005-03-31 3 / 2007-01-29 Type numbers 1728 External Presentation unit (S/W V1.2). 1728SE / 1728UK: Designation texts on the front in Swedish / English. NOTE! In Swedish convention (SBF): "General fault" presentation but no buzzer and no "General disablement" presentation. 1582 External FBP interface board. (Required in EBL512 / 500 when SW mode 1826/28 – 1582 shall be used.) 1587 External FBP / DU...

Open the catalog to page 2

All Panasonic Electric Works Europe catalogs and technical brochures

  1. FM-200

    12 Pages

  2. FPWIN Pro

    8 Pages

  3. GX-F/H SERIES

    16 Pages

  4. IONIZER

    36 Pages

  5. AC Servo

    155 Pages

  6. Overview HMI

    36 Pages

  7. UJ30/35

    12 Pages

  8. Laser markers

    28 Pages

Archived catalogs

  1. MC-100EX/MS

    1 Pages

  2. Base 2324

    2 Pages

  3. Dicool

    24 Pages

  4. LT4H-W

    8 Pages

  5. P400 and P400S

    20 Pages

  6. A-Series

    6 Pages