ECO-POWER METERS
Open the catalog to page 1Panasonic Eco-POWER METERs overview Visualizing energy consumption to save energy Install Eco-POWER METERs in lighting equipment, air conditioners, and production equipment to measure power consumption and check the current status. Afterwards, with specific targets in place, the implementation and management of an energy savings plan is quick and simple. Visualizing target achievements improves the energy usage cycle and allows for changes to be made to maximize efficiency. Measurement Analysis Energy saving target setting Implementation and management of an energy saving plan 2 14/05/2012
Open the catalog to page 2Performance of Eco-POWER METERs : Available – : Not available KW2G Product name KW1M Expandable KW1M-H Standard KW7M KW4M DIN48x48 MEWTOCOL Modbus KW8M DIN48x96 Basic Built-in memory 1/5A CT input SD card DIN rail AKW1121 AKW7111 AKW5111, AKW5112, AKW5211 AKW5212 AKW8111 AKW8111H AKW8115 22.5 x 75 x 100 AKW51: 48 x 48 x 81.9 AKW52: 48 x 48 x 87.5 48 x 96 x 98.5 – Appearance Expansion unit AKW2110G AKW2010G AKW2152G 1) AKW1110 AKW1111 AKW2182G 1) Main unit Part no. Dimensions mm (W x H x D) 50 x 95 x 65 Mounting method DIN rail 25 x 95 x 65 75 x 90 x 50 – Screw installation – – – Mounting...
Open the catalog to page 4KW2G Panasonic’s new KW2G Eco-POWER METER allows you to manage energy more efficiently than ever. You can easily add up to 7 expansion units to the KW2G Eco-POWER METER, allowing you to gather data for several circuits at once. Features Measure power produced and consumed USB port for easy PC connection Simultaneous measurement of power and pulse input Up to 8 circuits for 1-phase, 3-wire and 3-phase, 3-wire systems, or 16 circuits for 1-phase, 2-wire systems Main unit can display measured values for both itself and expansion units Easy expansion: Eliminate excess wiring by using up to...
Open the catalog to page 5KW2G Up to 16 circuits Expandable and efficient Single-phase, two-wire system Save space Save wiring 8-unit connecton Pulse input (AKW2010G, AKW2152G) Item Count input mode Max. counting speed Min. input pulse width Input signal Pulse output (AKW2010G) Item Description Description Incremental (fixed) Number of output points 1 50kHz/30Hz (selectable) Insulation method Optical coupler 0.01ms (for 50kHz)/16.7ms (for 30 Hz), duty ratio = 1:1 Switch, relay, transistor (open collector) Short-circuit impedance: max. 1kΩ Short-circuit residual voltage: max. 2V Impedance when open: min. 100kΩ Output...
Open the catalog to page 6Features 1 Easy, wire-saving expansion Eliminate excess wiring by using up to seven expansion units to add the required number of CT inputs for your application. Connector for easy expansion 8 units in total Main unit Expansion unit Up to 7 expansion units can be added Wiresaving! Power supply Measurement values CT CT CT CT CT CT CT CT CT CT CT CT CT CT 16 circuits (1-phase, 2-wire system) 8 circuits (1-phase, 3-wire system and 3-phase, 3-wire system) CT CT ŶData display for each unit Displaying main unit data H H 1 2 Displaying expansion unit data 2 H 3 1 2 3 The main unit can display data...
Open the catalog to page 7KW1M / KW1M-H The Panasonic KW1M Eco-POWER METER, which consumes less power itself than its predecessor, can be hooked up directly to industrial 400V AC networks. Features Screw and DIN-rail installation possible Integrated RS485 interface (Modbus RTU/MEWTOCOL) Automatic logging of measurement data at numerous selectable intervals (can be saved on SD card) Diverse alarm functions, e.g. when current consumption levels are exceeded Clock/calendar function Suited for measuring 3-phase currents of up to 400V AC Monitors and displays the most important electrical parameters KW1M AKW1111 KW1M-H...
Open the catalog to page 8General specifications Item Description Rated operating voltage 100 to 240V AC Rated frequency 50/60Hz common Rated power consumption 6VA (AKW1110), 8VA (AKW1111, AKW1121) (240V AC at 25°C) Allowable operating voltage 85 to 264V AC (85 to 110% of rated operating voltage) Momentary power-off time 10ms Ambient temperature –10 to +50°C (–25 to +70°C at storage) Ambient humidity 30 to 85% RH (at 20°C, non-condensing) Display method LCD with backlight; top: green, 4-digit, 16-segment; bottom: amber, 6-digit, 7-segment Power failure memory EEPROM (min. 100000 overwrites) Weight Approx. 170g...
Open the catalog to page 9• Direct measurement of 400V power loads • Improved measurement function • Instantaneous electric power • Electric energy • Voltage and current measurement for each phase • Power factor • Simultaneous power and pulse measurement • Supports networking (up to 99 stations can be connected) • Built-in memory • Log data can be saved to memory of main unit • Built-in battery (for memory backup) • Protects log data and time measurements from power failures • Logging of electric energy by month, day and hour • Manual electric energy measurement • Clock/calendar function • Direct input of 1A or 5A...
Open the catalog to page 10General specifications Item Description Rated operating voltage 100 to 240V AC Rated frequency 50/60Hz common Rated power consumption 8VA (240V AC at 25°C) Allowable operating voltage 85 to 264V AC (85% to 110% of rated operating voltage) Momentary power-off time 10ms Ambient temperature –10 to +50°C (–25 to +70°C at storage) Ambient humidity 30 to 85% RH (at 20°C, non-condensing) Display method 8-digit, 7-segment LED Power failure memory EEPROM (min. 100000 overwrites) Size 48 x 96 x 98.5mm Weight (without mounting bracket) Approx. 235g (AKW8111), approx. 250g (AKW8111H), approx. 265g...
Open the catalog to page 11KW4M / KW7M Features Compatible with systems of up to 3-phase, 3-wire Support for 400V AC power measurement (use with external voltage transformer) Also easy to mount on a panel surface with a mounting frame (sold separately) Supports networking (RS485 port) Protective structure: IEC IP66 (only front panel with rubber gasket) UL-compliant DIN rail type (KW7M) ideal for installation in a panel KW4M KW7M Order guide Product name Phase and wire system KW4M Eco-POWER METER DIN 48x48 type KW7M Eco-POWER METER DIN-rail type 1) Rated operating voltage 1-phase, 2-wire system 1-phase, 3-wire system...
Open the catalog to page 12All Panasonic Electric Works Europe catalogs and technical brochures
-
FM-200
12 Pages
-
Automation Controls Catalog
14 Pages
-
FPWIN Pro
8 Pages
-
Automation Controls Catalog
14 Pages
-
GX-F/H SERIES
16 Pages
-
FOR SENSORS PRODUCT FINDER
2 Pages
-
Short form SENSORS
124 Pages
-
Programmable Logic Controllers
32 Pages
-
IONIZER
36 Pages
-
PhotoMOS Catalog
354 Pages
-
Catalog Automotive Relays
210 Pages
-
AC Servo
155 Pages
-
Sensor short form
132 Pages
-
MINAS A5 SERVO DRIVES
28 Pages
-
HIGHLIGHTS FOR ECO INNOVATIONS
12 Pages
-
Catalogue-connectors
158 Pages
-
Fire alarm systems 2013
28 Pages
-
Shortform Temperature Controller
28 Pages
-
ELECTROMECHANICAL RELAYS
626 Pages
-
EY 7443 Auto Drill & Driver
2 Pages
-
Sealing Guns 2012/2013
8 Pages
-
New Products Autumn 2012
20 Pages
-
Catalog MINAS A5 series
85 Pages
-
FP-Safe catalog
12 Pages
-
Overview HMI
36 Pages
-
Overview Eco-POWER METERs
20 Pages
-
Panasonic Automation Products
28 Pages
-
Catalog built-in sensors
66 Pages
-
Catalog Microwave Devices
69 Pages
-
LC4H - digital counter
9 Pages
-
Limit switches AZH
14 Pages
-
Fire alarm system 2011/2012
28 Pages
-
Imagechecker P400XD
20 Pages
-
2D Code Reading Sensor PD60 / 65
12 Pages
-
FP-e: PLC for panel mounting
8 Pages
-
UJ30/35
12 Pages
-
GN-series touch terminals
36 Pages
-
Laser markers
28 Pages
-
Catalog timers & counters
160 Pages
-
Catalog limit switches
52 Pages
-
PHOTOMOS & SOLID STATE RELAYS
356 Pages
-
Catalog Switches
186 Pages
Archived catalogs
-
P400MA and P400 Imagecheckers
20 Pages
-
Turquoise switch series
28 Pages
-
Catalogue operation switches
156 Pages
-
R-1755 R-1650
2 Pages
-
Laserdrillable Prepreg
1 Pages
-
R-1566W R-1551W
1 Pages
-
MC-100EX/MS
1 Pages
-
Base 2324
2 Pages
-
Heat detectors 4375 and 4376
2 Pages
-
Multi detector 4350
2 Pages
-
Addressable siren 3377
2 Pages
-
External power supply 3366
2 Pages
-
Analog base 3312F / FL
2 Pages
-
Analog base 3312
2 Pages
-
Analog multi detector 4300
2 Pages
-
Analog heat detector 3308
2 Pages
-
Fire alarm system EBL128
2 Pages
-
Fire alarm system EBL512
2 Pages
-
Dicool
24 Pages
-
Eco-POWER METER KW4S
6 Pages
-
KW4M Eco-POWER METER
4 Pages
-
KW8M Eco-POWER METER
8 Pages
-
S1DX – analog timer
6 Pages
-
PM4H-W - analog timer - twin
5 Pages
-
PM4H - analog timer
6 Pages
-
PM5S - analog DIN-rail timer
7 Pages
-
QM4H - digital timer
4 Pages
-
LT4H-W
8 Pages
-
LT4H - digital timer
6 Pages
-
KR20 Wireless Unit
8 Pages
-
PV500 Imagechecker
20 Pages
-
Micro-Imagechecker AX30/AX40
16 Pages
-
PV310 Micro-Imagechecker
12 Pages
-
LightPix AE20
4 Pages
-
PD60/65 2D Code Readers
6 Pages
-
Panasonic Automation Products
12 Pages
-
Push Button Switches - ND Series
41 Pages
-
Push Button Switches - NS Series
11 Pages
-
AJ9 (J9) SWITCHES
6 Pages
-
AJ7 (J7) SWITCHES
8 Pages
-
AJ4 (J4) TOGGLE SWITCHES
6 Pages
-
TURQUOISE SNAP SWITCHES (AJN1/2)
10 Pages
-
Catalogue snap action relays
124 Pages
-
Electromechanical Relays
571 Pages
-
P400 and P400S
20 Pages
-
Micro-Imagechecker AX40
16 Pages
-
Brochure "2D Code Reader PD50"
12 Pages
-
A-Series
6 Pages
-
Brochure "LightPix AE20"
4 Pages
-
Imagechecker Brochure
32 Pages
-
Easy User Guide 'Matching'
5 Pages