Catalog excerpts
Eco-POWER METER Eco-COUNT METER Eco-HOUR METER Eco-POWER METER For maintenance and control in applications involving energy saving and environmental protection Simple Watt-Hour Meter KW4S Building Plant Integrated electrical energy Voltage Current Electricity charge Keeping a watchful eye. Line process CT Air conditioner PC Lights Elevator Constant-temperature oven On the lookout for wasted electricity! Now even more powerful with communication function and easy PLC connection! Eco-3 Brothers Eco-POWER METER KW4S ARCT1B247E ’05.1 Matsushita Electric Works, Ltd. http://www.nais-e.com/ Panasonic...the new name for 01/2005
Open the catalog to page 1Shrink-wrapping machine Back Front 1 2 Measuring electric power with Eco-POWER METER and dedicated CT. GD breaker Dedicated CT Dedicated CT Electromagnetic Heater switch FP0 Electric power measured by the Eco-POWER METER is output as pulses and then measured at a PLC (FP0). Eco-POWER METER pulse output function The pulses are converted to integrated electric power and when the value exceeds a certain amount, the heater power supply output is turned off. Clamp a CT below the machine’s power supply breaker and measure the power consumption with the Eco-POWER METER. Easy connection • Please...
Open the catalog to page 2Shrinkwrapping machine 1 2 Using RS485 (reduced wiring with two twisted pair cables), up to 31 Eco-POWER METERs can be connected. Dedicated CT Pulse output Data from each machine is collected using the Eco-POWER METER dedicated data collection software (AKW4805) and then saved as a CSV file. Using spreadsheet software such as Excel, data can be freely edited (turned into graphs) and saved. Daily and monthly reports can be created. 1. Standalone measurement 2. Data management with PLC 3. Data management with computer (Using data collection software) 4. Gathering data with PLC 5. Managing...
Open the catalog to page 3PCWAY (Operation Data Managing Software) Pie graph Line graph Have your mobile phone notified by email if there is a significant increase in electric power usage. Using RS485 (reduced wiring with two twisted pair cables), up to 99 Eco-POWER METERs can be connected. Email function also included Food warehouse Plant Building Outlets Office automation Lights Air conditioner Supermarket Web Datalogger Unit Web Datalogger Unit Web Datalogger Unit Internet Telephone infrastructure All types of networks Supermarket FPÓ Electric power watching in manufacturing lines Electric power watching using...
Open the catalog to page 4Current Changes Dedicated protocol and MEWTOCOL 1 to 99 (Note) Setting start ¨ Protocol switch (dedicated or MEWTOCOL) ¨ Communication format change Above content and communication procedure added. Features added Change Communication protocol Station number setting Communication format setting Instruction Manual Only dedicated protocol 1 to 31 Setting start ¨ Communication format change — œCommunication specifications œMEWTOCOL-COM commands œTypes Interface Protocol Isolation status No. of connected units Transmission distance Transmission speed (Baud rate) Transmission data format...
Open the catalog to page 5All Panasonic Electric Works Europe catalogs and technical brochures
-
FM-200
12 Pages
-
Automation Controls Catalog
14 Pages
-
FPWIN Pro
8 Pages
-
Automation Controls Catalog
14 Pages
-
GX-F/H SERIES
16 Pages
-
FOR SENSORS PRODUCT FINDER
2 Pages
-
Short form SENSORS
124 Pages
-
Programmable Logic Controllers
32 Pages
-
IONIZER
36 Pages
-
PhotoMOS Catalog
354 Pages
-
Catalog Automotive Relays
210 Pages
-
AC Servo
155 Pages
-
Sensor short form
132 Pages
-
MINAS A5 SERVO DRIVES
28 Pages
-
HIGHLIGHTS FOR ECO INNOVATIONS
12 Pages
-
Catalogue-connectors
158 Pages
-
Fire alarm systems 2013
28 Pages
-
Shortform Temperature Controller
28 Pages
-
ELECTROMECHANICAL RELAYS
626 Pages
-
EY 7443 Auto Drill & Driver
2 Pages
-
Sealing Guns 2012/2013
8 Pages
-
New Products Autumn 2012
20 Pages
-
Catalog MINAS A5 series
85 Pages
-
FP-Safe catalog
12 Pages
-
Overview HMI
36 Pages
-
Overview Eco-POWER METERs
20 Pages
-
Panasonic Automation Products
28 Pages
-
Catalog built-in sensors
66 Pages
-
Catalog Microwave Devices
69 Pages
-
LC4H - digital counter
9 Pages
-
Limit switches AZH
14 Pages
-
Fire alarm system 2011/2012
28 Pages
-
Imagechecker P400XD
20 Pages
-
2D Code Reading Sensor PD60 / 65
12 Pages
-
FP-e: PLC for panel mounting
8 Pages
-
UJ30/35
12 Pages
-
GN-series touch terminals
36 Pages
-
Eco-power meters
16 Pages
-
Laser markers
28 Pages
-
Catalog timers & counters
160 Pages
-
Catalog limit switches
52 Pages
-
PHOTOMOS & SOLID STATE RELAYS
356 Pages
-
Catalog Switches
186 Pages
Archived catalogs
-
P400MA and P400 Imagecheckers
20 Pages
-
Turquoise switch series
28 Pages
-
Catalogue operation switches
156 Pages
-
R-1755 R-1650
2 Pages
-
Laserdrillable Prepreg
1 Pages
-
R-1566W R-1551W
1 Pages
-
MC-100EX/MS
1 Pages
-
Base 2324
2 Pages
-
Heat detectors 4375 and 4376
2 Pages
-
Multi detector 4350
2 Pages
-
Addressable siren 3377
2 Pages
-
External power supply 3366
2 Pages
-
Analog base 3312F / FL
2 Pages
-
Analog base 3312
2 Pages
-
Analog multi detector 4300
2 Pages
-
Analog heat detector 3308
2 Pages
-
Fire alarm system EBL128
2 Pages
-
Fire alarm system EBL512
2 Pages
-
Dicool
24 Pages
-
KW4M Eco-POWER METER
4 Pages
-
KW8M Eco-POWER METER
8 Pages
-
S1DX – analog timer
6 Pages
-
PM4H-W - analog timer - twin
5 Pages
-
PM4H - analog timer
6 Pages
-
PM5S - analog DIN-rail timer
7 Pages
-
QM4H - digital timer
4 Pages
-
LT4H-W
8 Pages
-
LT4H - digital timer
6 Pages
-
KR20 Wireless Unit
8 Pages
-
PV500 Imagechecker
20 Pages
-
Micro-Imagechecker AX30/AX40
16 Pages
-
PV310 Micro-Imagechecker
12 Pages
-
LightPix AE20
4 Pages
-
PD60/65 2D Code Readers
6 Pages
-
Panasonic Automation Products
12 Pages
-
Push Button Switches - ND Series
41 Pages
-
Push Button Switches - NS Series
11 Pages
-
AJ9 (J9) SWITCHES
6 Pages
-
AJ7 (J7) SWITCHES
8 Pages
-
AJ4 (J4) TOGGLE SWITCHES
6 Pages
-
TURQUOISE SNAP SWITCHES (AJN1/2)
10 Pages
-
Catalogue snap action relays
124 Pages
-
Electromechanical Relays
571 Pages
-
P400 and P400S
20 Pages
-
Micro-Imagechecker AX40
16 Pages
-
Brochure "2D Code Reader PD50"
12 Pages
-
A-Series
6 Pages
-
Brochure "LightPix AE20"
4 Pages
-
Imagechecker Brochure
32 Pages
-
Easy User Guide 'Matching'
5 Pages