Base 2324
2Pages

{{requestButtons}}

Catalog excerpts

Base 2324 - 1

Panasonic Electric Works Fire & Security Technology Europe AB Jungmansgatan 12, SE-211 19 Malmö, Sweden Tel: +46 (0)40 697 70 00 • Fax: +46 (0)40 697 70 99 info-fste@eu.pewg.panasonic.com • www.panasonic-fire-security.com Fire alarm systems Base 2324 • Common base for the different conventional detectors • Easy connections incl. output for external LED • Locking mechanism Common base The base 2324 is connected to a zone line input for conventional alarm points. Conventional heat, smoke and multi detector types 23xx / 43xx / 627x can be plugged in the base. (See Product Leaflet for the detector type respectively.) The base is supplied with an LED that will light when the detector, plugged in the base, goes into alarm. Easy connection The base has screw terminals for the zone line (in/out) and external indicator (LED) e.g. 2218. Locking mechanism The base has a mechanical locking mechanism for conventional detector types 23xx / 43xx / 627x. The locking mechanism can be disabled. Miscellaneous Fault signal is obtained in the c.i.e. if the detector is un-plugged, i.e. all the following alarm points on the zone line become disabled. For more information regarding detector types, connections, etc. see Planning Instructions and connection diagrams for the system respectively. Product applications Used in the systems EBL500 / 512 / 128 / 1000 / 2000 provided with some zone line inputs for the system respectively (e.g. an 8 zones expansion board 1580 / 4580 input, an addressable zone interface 2226 / 2335 input, an addressable multi purpose I/O unit 3361 input, etc.). The base is intended for indoor use and in dry premises.

Open the catalog to page 1
Base 2324 - 2

All technical features and data are subject to changes without notice, resulting from continuous development and improvement. Product Leaflet Date of issue Revision / Date of revision MEW00008 2000-05-12 5 / 2008-09-23 Type number 2324 Base (for conventional detectors) 73 mm 50 mm Locking mechanism IN OUT Ext. LED LED A+ / B- = Zone line (in/out). A+ / L = Ext. LED output. Terminal wire diameter 0.6 – 1.6 mm (approx. 0.3 – 2 mm2). Between B-in and B-out is a contact that is closed when the detector is plugged in the base. Conventional detector types 23xx, 43xx and 627x can be plugged in the...

Open the catalog to page 2

All Panasonic Electric Works Europe catalogs and technical brochures

  1. FM-200

    12 Pages

  2. FPWIN Pro

    8 Pages

  3. GX-F/H SERIES

    16 Pages

  4. IONIZER

    36 Pages

  5. AC Servo

    155 Pages

  6. Overview HMI

    36 Pages

  7. UJ30/35

    12 Pages

  8. Laser markers

    28 Pages

Archived catalogs

  1. MC-100EX/MS

    1 Pages

  2. Dicool

    24 Pages

  3. LT4H-W

    8 Pages

  4. P400 and P400S

    20 Pages

  5. A-Series

    6 Pages