Alert annunciation units 1735 and 1736
2Pages

{{requestButtons}}

Catalog excerpts

Alert annunciation units 1735 and 1736 - 1

Panasonic Electric Works Fire & Security Technology Europe AB Citadellsvägen 23, SE-211 18 Malmö, Sweden Tel: +46 (0)40 697 70 00 • Fax: +46 (0)40 697 70 99 info@mfstech.com • www.panasonic-fire-security.com Fire alarm systems Alert annunciation units 1735 and 1736 • Control and indicating unit for alert annunciation • Compact size Alert annunciation unit When the Alert Annunciation function shall be used in the systems EBL512 & EBL128 an AA unit is required to present the AA alarms and for the related manoeuvres, i.e. to acknowledge / reset the alarms. For a detailed description of the AA function, see Planning and Operating instructions for the system respectively. Point or zone alarm presentation is as in the c.i.e. it is connected to. When there are queued alarms in the system, you can scroll amongst them. All or selected alarms will be presented in the unit's display (LCD, 2x40 characters with back-light). A user definable text message will be presented together with each alarm, if programmed in the c.i.e. Furthermore, > 617 texts can for selected alarms be stored in the unit and will in that case be shown, instead of the texts sent from the c.i.e. for these alarms. A builtin buzzer will sound to indicate a not acknowledged AA alarm. The unit is power supplied via the c.i.e. or ext. power supply. LEDs, push buttons etc. The unit has the following LEDs: • Fire and Alarms queued, indicating fire alarm / AA alarm. • Operation, indicating that the AA function is enabled in the system. Normally a time channel is used to enable this function. • Fire brigade alerted, indicating that the "Fire brigade tx" output is activated in the c.i.e. because: - the activated alarm is not an AA alarm - the AA function has been ended, e.g. the acknowledge or investigation time has run out, etc. • Acknowledge, indicating that the AA alarm has been acknowledged. The unit has the following push buttons: • Alarms queued, used to scroll amongst the alarms. • Acknowledge, used to acknowledge an AA alarm and hereby also silence the buzzer. • Reset, used to reset an AA alarm. 1735 has the designation texts in Swedish. 1736 has a neutral front for other languages, see the opposite side of this page. (This front also holds one extra LED & two extra push buttons.) Compact size The compact size enclosure is made of grey high impact ABS. Fitted with a supplementary "O" ring gasket, it will comply with IP61, in respect of dust and moisture. The unit has no door, i.e. the front is accessed directly, when required. The push buttons are disabled until they are supposed to be used. The unit shall be wall mounted. Two compression glands are attached. SW mode and address setting The display and the push buttons are used to set the SW mode and address. The SW modes are described on the opposite side of this page. Product application The units are intended for indoor use and in dry premises. They are intended to be used in the systems EBL512 & EBL128. An External FBP / DU interface board 1587 is required in the EBL512 c.i.e. and a 4552 Transceiver component in the EBL128 c.i.e.

Open the catalog to page 1
Alert annunciation units 1735 and 1736 - 2

All technical features and data are subject to changes without notice, resulting from continuous development and improvement. Product Leaflet Date of issue Revision / Date of revision MEW00278 2003-04-16 3 / 2006-08-31 Type numbers 1735 Alert annunciation unit. Swedish designation texts. 1736 Alert annunciation unit. Designation texts in any language. 1587 External FBP / DU interface board in EBL512, for connection of the 1735 and 1736 units in system EBL512. (Software version > 2.2 is required.) 4552 RS485 transceiver component, for connection of up to four display units, e.g. Alert...

Open the catalog to page 2

All Panasonic Electric Works Europe catalogs and technical brochures

  1. FM-200

    12 Pages

  2. FPWIN Pro

    8 Pages

  3. GX-F/H SERIES

    16 Pages

  4. IONIZER

    36 Pages

  5. AC Servo

    155 Pages

  6. Overview HMI

    36 Pages

  7. UJ30/35

    12 Pages

  8. Laser markers

    28 Pages

Archived catalogs

  1. MC-100EX/MS

    1 Pages

  2. Base 2324

    2 Pages

  3. Dicool

    24 Pages

  4. LT4H-W

    8 Pages

  5. P400 and P400S

    20 Pages

  6. A-Series

    6 Pages