Addressable sounder base 3379
2Pages

{{requestButtons}}

Catalog excerpts

Addressable sounder base 3379 - 1

Panasonic Electric Works Nordic AB Jungmansgatan 12, SE-211 19 Malmö, Sweden Tel: +46 (0)40 697 70 00 • Fax: +46 (0)40 697 70 99 info-fste@eu.pewg.panasonic.com • www.panasonic-fire-security.com Fire alarm systems Addressable sounder base 3379 „h Programmable sounder „h Three different sound types and priority levels „h Connected directly on the COM loop General 3379 consists of an analog base (similar to 3312) mounted together with a sounder, which gives an attractive design. The unit is mounted in the ceiling and a smoke (or heat) detector can be plugged in the base. The base is connected directly to the COM loop like the base 3312. Programmable output The sounder is programmed (via Win512, Win128, etc.) like a programmable output in the EBL system respectively. The sounder is mostly used as a fire alarm device but any of the trigger conditions can be used in the control expression. Priority levels Three priority levels (High, Medium & Low) are available (two in system EBL128). For each priority level an output control expression and a sound type is programmed. The sounder can, for example, be used for pre-warning, fire alarm and general fire alarm with a different sound for each type of alarm. Sound types The frequency is 3650 ± 350 Hz for all three Sound types. 1. Steady (continuous) 2. 3 Hz (167 ms on / 167 ms off) 3. 1 Hz (500 ms on / 500 ms off) Address & Mode setting The COM loop address for the Addressable sounder base 3379 is set with the Address setting tool 3314. The sounder base has to have one address and the detector plugged in the base has to have another address. 3314 is also used to set the mode: „h NORMAL mode: Shall be used for 3379 in all systems. „h 2330 mode: Cannot be used. „h 2312 mode: Cannot be used. Miscellaneous 3379 is power supplied via the COM loop, i.e. the number of sounder bases is depending on the other units connected to the same COM loop as well as the cable type/length. See Planning Instructions for the EBL system respectively. 3379 will replace the Addressable sounder base 3378. Product applications Used in the systems EBL512 (SW version > 2.2), EBL512 G3 and EBL128 when a sounder is required in the same room as a detector (e.g. in a hotel room). The sounder base is intended for indoor use and in dry premises.

Open the catalog to page 1
Addressable sounder base 3379 - 2

All technical features and data are subject to changes without notice, resulting from continuous development and improvement. Product Leaflet Date of issue Revision / Date of revision MEW01203 2009-06-01 2 / 2009-11-25 Type number 3379 Addressable sounder base (sounder & analog base in one unit) External LED output (terminals E+ and E-): 5 V, max. 2 mA. One External indicator (LED), e.g. 2218, can be connected to the base. NOTE! The COM loop address for 3379 has to be set before the COM loop is connected. Another COM loop address has to be set for the detector plugged in the base. See also...

Open the catalog to page 2

All Panasonic Electric Works Europe catalogs and technical brochures

  1. FM-200

    12 Pages

  2. FPWIN Pro

    8 Pages

  3. GX-F/H SERIES

    16 Pages

  4. IONIZER

    36 Pages

  5. AC Servo

    155 Pages

  6. Overview HMI

    36 Pages

  7. UJ30/35

    12 Pages

  8. Laser markers

    28 Pages

Archived catalogs

  1. MC-100EX/MS

    1 Pages

  2. Base 2324

    2 Pages

  3. Dicool

    24 Pages

  4. LT4H-W

    8 Pages

  5. P400 and P400S

    20 Pages

  6. A-Series

    6 Pages