Catalog excerpts
HOUR METER TH23 series (with reset function) 1. High-performance compact synchronous motor The accurately turning motor is employed to provide for longer period of measurement. 2. Compact and stylish 3. Easier wiring The flat terminals (#187) are quick and easy to connect. 4. Rotary indicator The rotary indicator makes one turn every 2 minutes for monitoring. 5. Compliant with UL, CSA and CE. Typical applications Maintenance management of machine tools, automated machines, control panels, forming machines, medical equipment, generators, compressors, water treatment facilities, presses, motors, etc. TH13 series (without reset function) RoHS Directive compatibility information http://www.nais-e.com/ Specifications Rated operating voltage Allowable operating voltage range Rated frequency 100V AC, 200V AC, 110V AC, 115 to 120V AC, 220V AC, 240V AC 85 to 115% of rated operating voltage 50 Hz, 60 Hz (other model) 0 to 99999.9 hours (TH13 series) 0 to 9999.9 hours (TH23 series) 0.1 hours (6 min) Approx. 1.5 W Min. 100 MΩ, Between live and dead metal parts (At 500V DC) 2,000 Vrms, Between live and dead metal parts 55°C 131°F 10 to 55 Hz: 1 cycle/min double amplitude of 0.5 mm (10 min on 3 axes) Min. 98 m/s2 {10 G} (4 times on 3 axes) Min. 980 m/s2 {100 G} (5 times on 3 axes) –10 to +50°C +14 to 122°F Max. 85% RH (non-condensing) 135 g 4.76 oz 130 g 4.59 oz Counting range Minimum time display Rated power consumption Insulation resistance (Initial value) Breakdown voltage (Initial value) Max. temperature rise Vibration resistance Functional Functional Shock resistance Destructive Ambient temperature Ambient humidity Weight Product types Type TH13 types (without reset button) TH23 types (with reset button) Note) The 115 to 120V AC, 220V AC and 240V AC types are UL-recognized and CSA-certified. For those products, specify “U” at the end of the part number when ordering. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Open the catalog to page 1TH13·TH23 Applicable standard Safety standard Pollution Degree 2/Overvoltage Category II (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity 4 kV contact 8 kV air EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (895 MHz to 905 MHz) EN61000-4-4 2 kV (power supply line) EN61000-4-5 1 kV (power line) EN61000-4-6 10 V/m AM modulation (0.15 MHz to 80 MHz) EN61000-4-8 30 A/m (50 Hz) EN61000-4-11 10 ms, 30% (rated voltage) 100 ms, 60% (rated voltage) 1,000 ms, 60% (rated voltage) 5,000 ms, 95%...
Open the catalog to page 2PRECAUTIONS IN USING THE HOUR METERS 1. Frequency setting Frequency is specified for AC motor-driven hour meters. Before installing, be sure to check your local power frequency. 2. Connections • TH13,23,14,24,40,50,63,64 For measuring energized time of load Single phase Three phases For measuring operation time of load Hour meter Hour meter Load Hour meter Hour meter Switch (Linked with clutch) Switch (Linked with clutch) Load Note) Make the connection with the accompanying flat connector first and then with the hour meter's terminal (#187). In such case, be sure to cover the connection...
Open the catalog to page 3DIN48 SIZE HOUR METER Silver panel Black panel TH24 series (with reset button) 1. High-performance compact syncronous motor The accurately turning motor is employed to provide for longer period of measurement. 2. Common for 50/60 Hz power frequency A lever is used to select 50 Hz or 60 Hz. There is no need to rearrange the control panel and other signal destinations. 3. Dimensions as per DIN 43700 standard The units are in the 48 × 48 DIN standard size. They can be fitted in panels and give refined metallic appearance. 4. Easier wiring The flat terminals (#187) are quick and easy to...
Open the catalog to page 4TH14·TH24 Applicable standard Safety standard Pollution Degree 2/Overvoltage Category II (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity 4 kV contact 8 kV air EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (895 MHz to 905 MHz) EN61000-4-4 2 kV (power supply line) EN61000-4-5 1 kV (power line) EN61000-4-6 10 V/m AM modulation (0.15 MHz to 80 MHz) EN61000-4-8 30 A/m (50 Hz) EN61000-4-11 10 ms, 30% (rated voltage) 100 ms, 60% (rated voltage) 1,000 ms, 60% (rated voltage) 5,000 ms, 95%...
Open the catalog to page 5PRECAUTIONS IN USING THE HOUR METERS 1. Frequency setting Frequency is specified for AC motor-driven hour meters. Before installing, be sure to check your local power frequency. 2. Connections • TH13,23,14,24,40,50,63,64 For measuring energized time of load Single phase Three phases For measuring operation time of load Hour meter Hour meter Load Hour meter Hour meter Switch (Linked with clutch) Switch (Linked with clutch) Load Note) Make the connection with the accompanying flat connector first and then with the hour meter's terminal (#187). In such case, be sure to cover the connection...
Open the catalog to page 6DIN48 DUAL INDICATOR HOUR METER Features 1. Upgraded composite function Specified-period measurement and total-time measurement can be monitored on a single hour meter. 2. High-performance compact syncronous motor The accurately turning motor is employed to provide for longer period of measurement. 3. Common for 50/60 Hz power frequency A lever is used to select 50 Hz or 60 Hz. There is no need to rearrange the control panel and other signal destinations. 4. Dimensions as per DIN 43700 standard The units are in the 48 × 48 DIN standard size. They can be fitted in panels and give refined...
Open the catalog to page 7TH40 Applicable standard Safety standard Pollution Degree 2/Overvoltage Category II (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity 4 kV contact 8 kV air EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (895 MHz to 905 MHz) EN61000-4-4 2 kV (power supply line) EN61000-4-5 1 kV (power line) EN61000-4-6 10 V/m AM modulation (0.15 MHz to 80 MHz) EN61000-4-8 30 A/m (50 Hz) EN61000-4-11 10 ms, 30% (rated voltage) 100 ms, 60% (rated voltage) 1,000 ms, 60% (rated voltage) 5,000 ms, 95%...
Open the catalog to page 8All Panasonic Electric Works Corporation of America catalogs and technical brochures
-
SP-Cap
32 Pages
-
TQC series
7 Pages
-
ZF-A series
9 Pages
-
EEH-ZE Series
9 Pages
-
ZC-A series
9 Pages
-
EEH-AZA1E151B
9 Pages
-
PAN1780‑AT
37 Pages
-
LD-P RELAYS
8 Pages
-
ERJH2CF1R33X
7 Pages
-
R35K (0.35 mm pitch
10 Pages
-
ZKU series
9 Pages
-
LQ RELAYS
9 Pages
-
SF-M RELAYS
8 Pages
-
PhotoMOS HF
14 Pages
-
ZU series
9 Pages
-
ZSU series
9 Pages
-
ZSU-A series
9 Pages
-
PAN1781
23 Pages
-
PAN9520 ETU
35 Pages
-
PAN9520
36 Pages
-
Energy Solutions
15 Pages
-
Line Card Catalog
68 Pages
-
HE-V RELAYS
5 Pages
-
PAN1026A
2 Pages
-
Light touch switch
14 Pages
-
ETQ Series Power Choke CoiLs
1 Pages
-
DP3 Catalog
14 Pages
-
AQY DIP Flat Package Catalog
4 Pages
-
AQW DIP 2 Form A Catalog
4 Pages
-
AQV SOP Form B Catalog
4 Pages
-
AQ-K Catalog
3 Pages
-
AQ-F Catalog
5 Pages
-
ABS Catalog
11 Pages
-
A4F Catalog
9 Pages
-
EX-L200 series
12 Pages
-
LP-400 series
16 Pages
-
HL-G1 Series
16 Pages
-
D-Imager Catalog
2 Pages
-
A35S Catalog
8 Pages
-
a4-catalog
175 Pages
-
e-catalog
81 Pages
-
lighting-relays-catalog
6 Pages
-
kw-catalog
28 Pages
-
lh2h-catalog
8 Pages
-
kt-catalog
16 Pages
-
hl-azh-catalog
15 Pages
-
ql-az4-catalog
6 Pages
-
vl-az8-catalog
8 Pages
-
lt4h-catalog
16 Pages
-
pm5s-catalog
7 Pages
-
pmh-catalog
7 Pages
-
pv310-catalog
12 Pages
-
lightpix-ae20-catalog
8 Pages
-
S1DXM
30 Pages
-
SF4B-G
6 Pages
-
TH (Sensor)
16 Pages
-
UJ20
11 Pages
-
VL-T
19 Pages
-
LightPix AE20
8 Pages
-
LP-S500W
12 Pages
-
HL (AZH)
30 Pages
-
GT21C
24 Pages
-
FX-500
20 Pages
-
FM-200
12 Pages
-
EQ-500
12 Pages
-
DPC-DPH 100
22 Pages
-
DL (AZD1)
23 Pages
-
Lighting
43 Pages
-
AX40
12 Pages
-
VIC100
6 Pages
-
Programmable Controller FP2
20 Pages
-
FPSIGMA Programmable Controller
20 Pages
-
CX-400 Version 2
24 Pages
-
KW Catalog
17 Pages
-
LH2H Catalog
29 Pages
-
LCH Catalog
34 Pages
-
KT Catalog
20 Pages
-
AZ5 Catalog
22 Pages
-
LT4H Catalog
39 Pages
-
A100/200 Catalog
26 Pages
-
UJ30/35 Catalog
12 Pages
-
LP-F10 Catalog
4 Pages
-
LP-200 Catalog
6 Pages
-
NA1-11 Catalog
8 Pages
-
GN Catalog
10 Pages
-
Data Logger Light Catalog
4 Pages