cad

th-meter-catalog
18Pages

{{requestButtons}}

Catalog excerpts

th-meter-catalog - 1

HOUR METER TH23 series (with reset function) 1. High-performance compact synchronous motor The accurately turning motor is employed to provide for longer period of measurement. 2. Compact and stylish 3. Easier wiring The flat terminals (#187) are quick and easy to connect. 4. Rotary indicator The rotary indicator makes one turn every 2 minutes for monitoring. 5. Compliant with UL, CSA and CE. Typical applications Maintenance management of machine tools, automated machines, control panels, forming machines, medical equipment, generators, compressors, water treatment facilities, presses, motors, etc. TH13 series (without reset function) RoHS Directive compatibility information http://www.nais-e.com/ Specifications Rated operating voltage Allowable operating voltage range Rated frequency 100V AC, 200V AC, 110V AC, 115 to 120V AC, 220V AC, 240V AC 85 to 115% of rated operating voltage 50 Hz, 60 Hz (other model) 0 to 99999.9 hours (TH13 series) 0 to 9999.9 hours (TH23 series) 0.1 hours (6 min) Approx. 1.5 W Min. 100 MΩ, Between live and dead metal parts (At 500V DC) 2,000 Vrms, Between live and dead metal parts 55°C 131°F 10 to 55 Hz: 1 cycle/min double amplitude of 0.5 mm (10 min on 3 axes) Min. 98 m/s2 {10 G} (4 times on 3 axes) Min. 980 m/s2 {100 G} (5 times on 3 axes) –10 to +50°C +14 to 122°F Max. 85% RH (non-condensing) 135 g 4.76 oz 130 g 4.59 oz Counting range Minimum time display Rated power consumption Insulation resistance (Initial value) Breakdown voltage (Initial value) Max. temperature rise Vibration resistance Functional Functional Shock resistance Destructive Ambient temperature Ambient humidity Weight Product types Type TH13 types (without reset button) TH23 types (with reset button) Note) The 115 to 120V AC, 220V AC and 240V AC types are UL-recognized and CSA-certified. For those products, specify “U” at the end of the part number when ordering. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

Open the catalog to page 1
th-meter-catalog - 2

TH13·TH23 Applicable standard Safety standard Pollution Degree 2/Overvoltage Category II (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity 4 kV contact 8 kV air EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (895 MHz to 905 MHz) EN61000-4-4 2 kV (power supply line) EN61000-4-5 1 kV (power line) EN61000-4-6 10 V/m AM modulation (0.15 MHz to 80 MHz) EN61000-4-8 30 A/m (50 Hz) EN61000-4-11 10 ms, 30% (rated voltage) 100 ms, 60% (rated voltage) 1,000 ms, 60% (rated voltage) 5,000 ms, 95%...

Open the catalog to page 2
th-meter-catalog - 3

PRECAUTIONS IN USING THE HOUR METERS 1. Frequency setting Frequency is specified for AC motor-driven hour meters. Before installing, be sure to check your local power frequency. 2. Connections • TH13,23,14,24,40,50,63,64 For measuring energized time of load Single phase Three phases For measuring operation time of load Hour meter Hour meter Load Hour meter Hour meter Switch (Linked with clutch) Switch (Linked with clutch) Load Note) Make the connection with the accompanying flat connector first and then with the hour meter's terminal (#187). In such case, be sure to cover the connection...

Open the catalog to page 3
th-meter-catalog - 4

DIN48 SIZE HOUR METER Silver panel Black panel TH24 series (with reset button) 1. High-performance compact syncronous motor The accurately turning motor is employed to provide for longer period of measurement. 2. Common for 50/60 Hz power frequency A lever is used to select 50 Hz or 60 Hz. There is no need to rearrange the control panel and other signal destinations. 3. Dimensions as per DIN 43700 standard The units are in the 48 × 48 DIN standard size. They can be fitted in panels and give refined metallic appearance. 4. Easier wiring The flat terminals (#187) are quick and easy to...

Open the catalog to page 4
th-meter-catalog - 5

TH14·TH24 Applicable standard Safety standard Pollution Degree 2/Overvoltage Category II (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity 4 kV contact 8 kV air EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (895 MHz to 905 MHz) EN61000-4-4 2 kV (power supply line) EN61000-4-5 1 kV (power line) EN61000-4-6 10 V/m AM modulation (0.15 MHz to 80 MHz) EN61000-4-8 30 A/m (50 Hz) EN61000-4-11 10 ms, 30% (rated voltage) 100 ms, 60% (rated voltage) 1,000 ms, 60% (rated voltage) 5,000 ms, 95%...

Open the catalog to page 5
th-meter-catalog - 6

PRECAUTIONS IN USING THE HOUR METERS 1. Frequency setting Frequency is specified for AC motor-driven hour meters. Before installing, be sure to check your local power frequency. 2. Connections • TH13,23,14,24,40,50,63,64 For measuring energized time of load Single phase Three phases For measuring operation time of load Hour meter Hour meter Load Hour meter Hour meter Switch (Linked with clutch) Switch (Linked with clutch) Load Note) Make the connection with the accompanying flat connector first and then with the hour meter's terminal (#187). In such case, be sure to cover the connection...

Open the catalog to page 6
th-meter-catalog - 7

DIN48 DUAL INDICATOR HOUR METER Features 1. Upgraded composite function Specified-period measurement and total-time measurement can be monitored on a single hour meter. 2. High-performance compact syncronous motor The accurately turning motor is employed to provide for longer period of measurement. 3. Common for 50/60 Hz power frequency A lever is used to select 50 Hz or 60 Hz. There is no need to rearrange the control panel and other signal destinations. 4. Dimensions as per DIN 43700 standard The units are in the 48 × 48 DIN standard size. They can be fitted in panels and give refined...

Open the catalog to page 7
th-meter-catalog - 8

TH40 Applicable standard Safety standard Pollution Degree 2/Overvoltage Category II (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity 4 kV contact 8 kV air EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (895 MHz to 905 MHz) EN61000-4-4 2 kV (power supply line) EN61000-4-5 1 kV (power line) EN61000-4-6 10 V/m AM modulation (0.15 MHz to 80 MHz) EN61000-4-8 30 A/m (50 Hz) EN61000-4-11 10 ms, 30% (rated voltage) 100 ms, 60% (rated voltage) 1,000 ms, 60% (rated voltage) 5,000 ms, 95%...

Open the catalog to page 8

All Panasonic Electric Works Corporation of America catalogs and technical brochures

  1. SP-Cap

    32 Pages

  2. TQC series

    7 Pages

  3. ZF-A series

    9 Pages

  4. ZC-A series

    9 Pages

  5. PAN1780‑AT

    37 Pages

  6. LD-P RELAYS

    8 Pages

  7. ERJH2CF1R33X

    7 Pages

  8. ZKU series

    9 Pages

  9. LQ RELAYS

    9 Pages

  10. SF-M RELAYS

    8 Pages

  11. PhotoMOS HF

    14 Pages

  12. ZU series

    9 Pages

  13. ZSU series

    9 Pages

  14. ZSU-A series

    9 Pages

  15. PAN1781

    23 Pages

  16. PAN9520 ETU

    35 Pages

  17. PAN9520

    36 Pages

  18. HE-V RELAYS

    5 Pages

  19. PAN1026A

    2 Pages

  20. DP3 Catalog

    14 Pages

  21. AQ-K Catalog

    3 Pages

  22. AQ-F Catalog

    5 Pages

  23. ABS Catalog

    11 Pages

  24. A4F Catalog

    9 Pages

  25. EX-L200 series

    12 Pages

  26. LP-400 series

    16 Pages

  27. HL-G1 Series

    16 Pages

  28. A35S Catalog

    8 Pages

  29. a4-catalog

    175 Pages

  30. e-catalog

    81 Pages

  31. kw-catalog

    28 Pages

  32. lh2h-catalog

    8 Pages

  33. kt-catalog

    16 Pages

  34. hl-azh-catalog

    15 Pages

  35. lt4h-catalog

    16 Pages

  36. pm5s-catalog

    7 Pages

  37. pmh-catalog

    7 Pages

  38. pv310-catalog

    12 Pages

  39. S1DXM

    30 Pages

  40. SF4B-G

    6 Pages

  41. TH (Sensor)

    16 Pages

  42. UJ20

    11 Pages

  43. VL-T

    19 Pages

  44. LP-S500W

    12 Pages

  45. HL (AZH)

    30 Pages

  46. GT21C

    24 Pages

  47. FX-500

    20 Pages

  48. FM-200

    12 Pages

  49. EQ-500

    12 Pages

  50. DPC-DPH 100

    22 Pages

  51. DL (AZD1)

    23 Pages

  52. Lighting

    43 Pages

  53. AX40

    12 Pages

  54. VIC100

    6 Pages

  55. KW Catalog

    17 Pages

  56. LH2H Catalog

    29 Pages

  57. LCH Catalog

    34 Pages

  58. KT Catalog

    20 Pages

  59. AZ5 Catalog

    22 Pages

  60. LT4H Catalog

    39 Pages

  61. GN Catalog