Catalog excerpts
Panasonic Products for Energy Management 1st edition Micro Grid Wind-power generation Photovoltaic generation
Open the catalog to page 1Products for Energy Management Products for Energy Management Application example Product examples for specific applications Application Introduction Photovoltaic Power Generation System • • • • • • • • • • • • • • P. 6 Battery Storage System Fast Charging Stations Smart Meter Lighting/Outlet Control • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • P.14 Rapid Shutdown System Product Features
Open the catalog to page 2Products for Energy Management Application example For Photovoltaic Power Generation System For Lighting/Outlet Control Lighting/Outlet Control Rapid Shutdown System Solar panel Built-in relay for junction box Solar panel Smart meter Solar inverter Power distributor Solar inverter AC power relay Smart meter Solid state relays Equipment receptacle Storage battery Electric power measurement unit DC power relay Eco-POWER METER Programmable Display DC power relay Programmable Current Display Transformer (CT) For Rapid Shutdown System For Battery Storage System Eco-POWER METER for reverse power...
Open the catalog to page 3Products for Energy Management Product examples for specific applications Recommended products for specific applications For photovoltaic power generation system For battery storage system For fast charging station For Lighting/ Outlet Control For rapid shut down system Product name 2 Form A/ 2 Form A 1 Form B Appearance Contact arrangement 100A Latching type availability Rated operating power Max. allowable voltage Safety standards Standard type Standard type High capacity type (1.5mm) 1.88W (when input) 0.17W (when retained) 1.92W (when input) 0.31W (when retained) − 1.4W (when input)...
Open the catalog to page 4For DC Load Switching PhotoMOS Product name Contact arrangement Rated operating power 0.08-0.64W 0.01W 6W (when input) 45W (when input) 1.9W (when input) (Input voltage: 4 to 32 V) 1.5W (when retained) 4W (when retained) 0.2W (when retained) (Input current: 10 mA) Ambient temperature (Capsule contact construction) Safety standards (Please contact our sales (Please contact our sales representative for details.) representative for details.) *1 Each 1 Form A contact connected in series. *2 When using each 1 Form A contact independently Product name Applications PhotoMOS Insulation detection...
Open the catalog to page 5New Product Introduction HE relay PV type 90 A Max. switching current: 90 A expected life: • 80 A 277V AC Min. 1×104 • 90 A 250V AC Min. 1×103 2. Compact size and low operating power 38 × L: 33 × H: 38.8mm operating power: 1,920 mW Holding power: 310 mW (when applied 40%V of coil holding voltage) with European photovoltaic standard VDE0126 Contact gap: 3.0 mm 1. High-capacity and long life (Form A contact) 2. Compact size and low operating power A 277V AC 3×104 (Standard type), 5×104 (Long life type) 20 A 277V AC 1×105 (Standard type), 2×105 (Long life type) W: 30 × L: 36 × H: 40...
Open the catalog to page 6Application Introduction Photovoltaic Power Generation System Recommended products For cutoff of solar strings Programmable Display Eco-POWER METER Measuring and displaying power generated, sold, and purchased For electrical shock prevention and bypass (efficiency improvement) • For AC safety cutoff • For operation in stand alone mode Power distributor [Power conditioner] AQ-A EP HE-V For DC safety cutoff Storage battery • Battery charge/discharge switching • For DC safety cutoff • For inrush current prevention Panasonic Corporation Electromechanical Control Business Division...
Open the catalog to page 7Application Introduction Photovoltaic Power Generation System Recommended products (DC side) High-voltage cutoff relay capable of simultaneously cutting off the positive (+) and negative (-) terminals by serially connecting the 1 Form A contact. Up to 1,000V DC cutoff *1,000 V DC is the maximum allowable voltage when each 1 Form A contact is connected in series. The rating is 800 V DC. HE-V When something shades the solar panels or a defect occurs, the total power generation efficiency of the system decreases. In such cases, the total power generation efficiency can be maintained by...
Open the catalog to page 8Recommended products (AC side) Programmable Display Eco-POWER METER Current Transformer (CT) Stand alone *When using HE-S relay. • LF-G (1a 22A, 33A 250V AC) Compact power relay with a 1.5mm or 1.8mm contact gap Recommended relay • HE-S (2a/2a1b 35A 277V AC) Two contacts compact power relay with 3.2mm contact gap • HE PV (1a 35A, 48A, 90A 277V AC) Compact power relay with a 2.5mm/3.0mm contact gap, capable of switching from 35A to 90A *Use one 2a1b type (creation of contact welding monitoring circuit is possible). For Safety Cutoff on the AC side Relays are used for safety cutoff on the...
Open the catalog to page 9Application Introduction Battery Storage System Recommended products Inverter Load AC/DC Storage battery (LF-G/HE PV: 1a 22A-90A 250V AC) (HE-S: 2a/2a1b 35A 277V AC) Storage battery Max. load voltage 1,500 V are available. For available types, please contact our sales representative. For detailed application, see page 11. *1 1,000 V DC is Max. switching voltage. The rating is 400 V DC. *2 1,000 V DC is Max. switching voltage when each 1 Form A contact is connected in series. The rating is 800 V DC. (EP : 1a 20A-300A 1,000V DC*) (AQ-A : 1a 10A 600V DC) *1,000 V DC is Max. switching voltage....
Open the catalog to page 10For Charge and Discharge AQ-A SSR (PhotoMOS) is used to switch charge and discharge. We recommend solid state relays for applications where there will be frequent ON/OFF switching. Regular operation Turn ON both solid state relays for charge and discharge control. Current flows in both directions. Charge control Over-charge prevention Discharge control Over-discharge prevention In order to prevent over charging, the solid state relay on the charge control side turns OFF. On the discharge side, current will flow because there is a diode. In order to prevent over discharging, the solid state...
Open the catalog to page 11All Panasonic Electric Works Corporation of America catalogs and technical brochures
-
SP-Cap
32 Pages
-
TQC series
7 Pages
-
ZF-A series
9 Pages
-
EEH-ZE Series
9 Pages
-
ZC-A series
9 Pages
-
EEH-AZA1E151B
9 Pages
-
PAN1780‑AT
37 Pages
-
LD-P RELAYS
8 Pages
-
ERJH2CF1R33X
7 Pages
-
R35K (0.35 mm pitch
10 Pages
-
ZKU series
9 Pages
-
LQ RELAYS
9 Pages
-
SF-M RELAYS
8 Pages
-
PhotoMOS HF
14 Pages
-
ZU series
9 Pages
-
ZSU series
9 Pages
-
ZSU-A series
9 Pages
-
PAN1781
23 Pages
-
PAN9520 ETU
35 Pages
-
PAN9520
36 Pages
-
Energy Solutions
15 Pages
-
Line Card Catalog
68 Pages
-
HE-V RELAYS
5 Pages
-
PAN1026A
2 Pages
-
Light touch switch
14 Pages
-
ETQ Series Power Choke CoiLs
1 Pages
-
DP3 Catalog
14 Pages
-
AQY DIP Flat Package Catalog
4 Pages
-
AQW DIP 2 Form A Catalog
4 Pages
-
AQV SOP Form B Catalog
4 Pages
-
AQ-K Catalog
3 Pages
-
AQ-F Catalog
5 Pages
-
ABS Catalog
11 Pages
-
A4F Catalog
9 Pages
-
EX-L200 series
12 Pages
-
LP-400 series
16 Pages
-
HL-G1 Series
16 Pages
-
D-Imager Catalog
2 Pages
-
A35S Catalog
8 Pages
-
a4-catalog
175 Pages
-
e-catalog
81 Pages
-
lighting-relays-catalog
6 Pages
-
kw-catalog
28 Pages
-
th-meter-catalog
18 Pages
-
lh2h-catalog
8 Pages
-
kt-catalog
16 Pages
-
hl-azh-catalog
15 Pages
-
ql-az4-catalog
6 Pages
-
vl-az8-catalog
8 Pages
-
lt4h-catalog
16 Pages
-
pm5s-catalog
7 Pages
-
pmh-catalog
7 Pages
-
pv310-catalog
12 Pages
-
lightpix-ae20-catalog
8 Pages
-
S1DXM
30 Pages
-
SF4B-G
6 Pages
-
TH (Sensor)
16 Pages
-
UJ20
11 Pages
-
VL-T
19 Pages
-
LightPix AE20
8 Pages
-
LP-S500W
12 Pages
-
HL (AZH)
30 Pages
-
GT21C
24 Pages
-
FX-500
20 Pages
-
FM-200
12 Pages
-
EQ-500
12 Pages
-
DPC-DPH 100
22 Pages
-
DL (AZD1)
23 Pages
-
Lighting
43 Pages
-
AX40
12 Pages
-
VIC100
6 Pages
-
Programmable Controller FP2
20 Pages
-
FPSIGMA Programmable Controller
20 Pages
-
CX-400 Version 2
24 Pages
-
KW Catalog
17 Pages
-
LH2H Catalog
29 Pages
-
LCH Catalog
34 Pages
-
KT Catalog
20 Pages
-
AZ5 Catalog
22 Pages
-
LT4H Catalog
39 Pages
-
A100/200 Catalog
26 Pages
-
UJ30/35 Catalog
12 Pages
-
LP-F10 Catalog
4 Pages
-
LP-200 Catalog
6 Pages
-
NA1-11 Catalog
8 Pages
-
GN Catalog
10 Pages
-
Data Logger Light Catalog
4 Pages