cad

Panasonic Products for Energy Management
28Pages

{{requestButtons}}

Catalog excerpts

Panasonic Products for Energy Management - 1

Panasonic Products for Energy Management 1st edition Micro Grid Wind-power generation Photovoltaic generation

Open the catalog to page 1
Panasonic Products for Energy Management - 2

Products for Energy Management Products for Energy Management Application example Product examples for specific applications Application Introduction Photovoltaic Power Generation System • • • • • • • • • • • • • • P. 6 Battery Storage System Fast Charging Stations Smart Meter Lighting/Outlet Control • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • P.14 Rapid Shutdown System Product Features

Open the catalog to page 2
Panasonic Products for Energy Management - 3

Products for Energy Management Application example For Photovoltaic Power Generation System For Lighting/Outlet Control Lighting/Outlet Control Rapid Shutdown System Solar panel Built-in relay for junction box Solar panel Smart meter Solar inverter Power distributor Solar inverter AC power relay Smart meter Solid state relays Equipment receptacle Storage battery Electric power measurement unit DC power relay Eco-POWER METER Programmable Display DC power relay Programmable Current Display Transformer (CT) For Rapid Shutdown System For Battery Storage System Eco-POWER METER for reverse power...

Open the catalog to page 3
Panasonic Products for Energy Management - 4

Products for Energy Management Product examples for specific applications Recommended products for specific applications For photovoltaic power generation system For battery storage system For fast charging station For Lighting/ Outlet Control For rapid shut down system Product name 2 Form A/ 2 Form A 1 Form B Appearance Contact arrangement 100A Latching type availability Rated operating power Max. allowable voltage Safety standards Standard type Standard type High capacity type (1.5mm) 1.88W (when input) 0.17W (when retained) 1.92W (when input) 0.31W (when retained) − 1.4W (when input)...

Open the catalog to page 4
Panasonic Products for Energy Management - 5

For DC Load Switching PhotoMOS Product name Contact arrangement Rated operating power 0.08-0.64W 0.01W 6W (when input) 45W (when input) 1.9W (when input) (Input voltage: 4 to 32 V) 1.5W (when retained) 4W (when retained) 0.2W (when retained) (Input current: 10 mA) Ambient temperature (Capsule contact construction) Safety standards (Please contact our sales (Please contact our sales representative for details.) representative for details.) *1 Each 1 Form A contact connected in series. *2 When using each 1 Form A contact independently Product name Applications PhotoMOS Insulation detection...

Open the catalog to page 5
Panasonic Products for Energy Management - 6

New Product Introduction HE relay PV type 90 A  Max. switching current: 90 A expected life: • 80 A 277V AC Min. 1×104 • 90 A 250V AC Min. 1×103 2. Compact size and low operating power 38 × L: 33 × H: 38.8mm operating power: 1,920 mW  Holding power: 310 mW (when applied 40%V of coil holding voltage) with European photovoltaic standard VDE0126  Contact gap: 3.0 mm 1. High-capacity and long life (Form A contact) 2. Compact size and low operating power A 277V AC 3×104 (Standard type), 5×104 (Long life type)  20 A 277V AC 1×105 (Standard type), 2×105 (Long life type)  W: 30 × L: 36 × H: 40...

Open the catalog to page 6
Panasonic Products for Energy Management - 7

Application Introduction Photovoltaic Power Generation System Recommended products For cutoff of solar strings Programmable Display Eco-POWER METER Measuring and displaying power generated, sold, and purchased For electrical shock prevention and bypass (efficiency improvement) • For AC safety cutoff • For operation in stand alone mode Power distributor [Power conditioner] AQ-A EP HE-V For DC safety cutoff Storage battery • Battery charge/discharge switching • For DC safety cutoff • For inrush current prevention Panasonic Corporation Electromechanical Control Business Division...

Open the catalog to page 7
Panasonic Products for Energy Management - 8

Application Introduction Photovoltaic Power Generation System Recommended products (DC side) High-voltage cutoff relay capable of simultaneously cutting off the positive (+) and negative (-) terminals by serially connecting the 1 Form A contact. Up to 1,000V DC cutoff *1,000 V DC is the maximum allowable voltage when each 1 Form A contact is connected in series. The rating is 800 V DC. HE-V When something shades the solar panels or a defect occurs, the total power generation efficiency of the system decreases. In such cases, the total power generation efficiency can be maintained by...

Open the catalog to page 8
Panasonic Products for Energy Management - 9

Recommended products (AC side) Programmable Display Eco-POWER METER Current Transformer (CT) Stand alone *When using HE-S relay. • LF-G (1a 22A, 33A 250V AC) Compact power relay with a 1.5mm or 1.8mm contact gap Recommended relay • HE-S (2a/2a1b 35A 277V AC) Two contacts compact power relay with 3.2mm contact gap • HE PV (1a 35A, 48A, 90A 277V AC) Compact power relay with a 2.5mm/3.0mm contact gap, capable of switching from 35A to 90A *Use one 2a1b type (creation of contact welding monitoring circuit is possible). For Safety Cutoff on the AC side Relays are used for safety cutoff on the...

Open the catalog to page 9
Panasonic Products for Energy Management - 10

Application Introduction Battery Storage System Recommended products Inverter Load AC/DC Storage battery (LF-G/HE PV: 1a 22A-90A 250V AC) (HE-S: 2a/2a1b 35A 277V AC) Storage battery Max. load voltage 1,500 V are available. For available types, please contact our sales representative. For detailed application, see page 11. *1 1,000 V DC is Max. switching voltage. The rating is 400 V DC. *2 1,000 V DC is Max. switching voltage when each 1 Form A contact is connected in series. The rating is 800 V DC. (EP : 1a 20A-300A 1,000V DC*) (AQ-A : 1a 10A 600V DC) *1,000 V DC is Max. switching voltage....

Open the catalog to page 10
Panasonic Products for Energy Management - 11

For Charge and Discharge AQ-A SSR (PhotoMOS) is used to switch charge and discharge. We recommend solid state relays for applications where there will be frequent ON/OFF switching. Regular operation Turn ON both solid state relays for charge and discharge control. Current flows in both directions. Charge control Over-charge prevention Discharge control Over-discharge prevention In order to prevent over charging, the solid state relay on the charge control side turns OFF. On the discharge side, current will flow because there is a diode. In order to prevent over discharging, the solid state...

Open the catalog to page 11

All Panasonic Electric Works Corporation of America catalogs and technical brochures

  1. SP-Cap

    32 Pages

  2. TQC series

    7 Pages

  3. ZF-A series

    9 Pages

  4. ZC-A series

    9 Pages

  5. PAN1780‑AT

    37 Pages

  6. LD-P RELAYS

    8 Pages

  7. ERJH2CF1R33X

    7 Pages

  8. ZKU series

    9 Pages

  9. LQ RELAYS

    9 Pages

  10. SF-M RELAYS

    8 Pages

  11. PhotoMOS HF

    14 Pages

  12. ZU series

    9 Pages

  13. ZSU series

    9 Pages

  14. ZSU-A series

    9 Pages

  15. PAN1781

    23 Pages

  16. PAN9520 ETU

    35 Pages

  17. PAN9520

    36 Pages

  18. HE-V RELAYS

    5 Pages

  19. PAN1026A

    2 Pages

  20. DP3 Catalog

    14 Pages

  21. AQ-K Catalog

    3 Pages

  22. AQ-F Catalog

    5 Pages

  23. ABS Catalog

    11 Pages

  24. A4F Catalog

    9 Pages

  25. EX-L200 series

    12 Pages

  26. LP-400 series

    16 Pages

  27. HL-G1 Series

    16 Pages

  28. A35S Catalog

    8 Pages

  29. a4-catalog

    175 Pages

  30. e-catalog

    81 Pages

  31. kw-catalog

    28 Pages

  32. lh2h-catalog

    8 Pages

  33. kt-catalog

    16 Pages

  34. hl-azh-catalog

    15 Pages

  35. lt4h-catalog

    16 Pages

  36. pm5s-catalog

    7 Pages

  37. pmh-catalog

    7 Pages

  38. pv310-catalog

    12 Pages

  39. S1DXM

    30 Pages

  40. SF4B-G

    6 Pages

  41. TH (Sensor)

    16 Pages

  42. UJ20

    11 Pages

  43. VL-T

    19 Pages

  44. LP-S500W

    12 Pages

  45. HL (AZH)

    30 Pages

  46. GT21C

    24 Pages

  47. FX-500

    20 Pages

  48. FM-200

    12 Pages

  49. EQ-500

    12 Pages

  50. DPC-DPH 100

    22 Pages

  51. DL (AZD1)

    23 Pages

  52. Lighting

    43 Pages

  53. AX40

    12 Pages

  54. VIC100

    6 Pages

  55. KW Catalog

    17 Pages

  56. LH2H Catalog

    29 Pages

  57. LCH Catalog

    34 Pages

  58. KT Catalog

    20 Pages

  59. AZ5 Catalog

    22 Pages

  60. LT4H Catalog

    39 Pages

  61. GN Catalog

    10 Pages