DIN 48 SIZE DIGITAL TIMER Features 1. Bright and Easy-to-Read Display A brand new bright 2-color back light LCD display. The easy-to-read screen in any location makes checking and setting procedures a cinch. 2. Simple Operation Seesaw buttons make operating the unit even easier than before. 3. Short Body of only 64.5 mm 2.539 inch (screw terminal type) or 70.1 mm 2.760 inch (pin type) With a short body, it is easy to install in even narrow control panels. 4. Conforms to IP66’s Weather Resistant Standards The water-proof panel keeps out water and dirt for reliable operation even in poor environments. Screw terminal type RoHS Directive compatibility information http://www.nais-e.com/ 5. Screw terminal (M3.5) and Pin Types are Both Standard Options The two terminal types are standard options to support either front panel installation or embedded installation. 6. Changeable Panel Cover Also offers a black panel cover to meet your design considerations. 7. Compliant with UL, c-UL and CE. Product types Time range Operating mode Operating voltage Power down insurance Terminal type Part number Screw terminal Screw terminal 9.999 s (0.001 s~) 99.99 s (0.01 s~) 999.9 s (0.1 s~) 9999 s (1 s~) 99 min 59 s (1 s~) 999.9 min (0.1 min~) 99 h 59 min (1 min~) 999.9 h (0.1 h~) Power ON delay (1) Power ON delay (2) Signal ON delay Signal OFF delay Pulse One-shot Pulse ON-delay Signal Flicker Totalizing ON-delay (8 modes) Screw terminal Screw terminal Screw terminal Screw terminal * A rubber gasket (ATC18002) and a mounting frame (AT8-DA4) are included. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

Open the catalog to page 1
lt4h-catalog - 2

Features 1. Economically priced in anticipation of market needs. • Economically priced to provide excellent cost performance. 2. Display is a bright reflective-type LCD. 3. Inherits all of the characteristics of the LT4H digital timer. • Seesaw switches ensure easy operation. • IP66 environmental protection. • Shortened body (70.1 mm 2.760 inch underhead). Product types Product name Time range Operating mode Power ON delay (1) Power ON delay (2) Signal ON delay Signal OFF delay Pulse One-shot Pulse ON-delay Signal Flicker Totalizing ON-delay (8 modes) Operating voltage Power down insurance...

Open the catalog to page 2
lt4h-catalog - 3

Ralay output type Transistor output type AC type AC/DC type DC type AC type AC/DC type DC type 100 to 240 V AC, 24 V AC, 100 to 240 V AC, 24 V AC, 12 to 24 V DC 12 to 24 V DC 24 V AC/DC 24 V AC/DC — 50/60 Hz common 50/60 Hz common — Max. 3 W Max. 10 V A Max. 10 V A Max. 3 W 5 A, 250 V AC (resistive load) 100 mA, 30 V DC 9.999 s, 99.99 s, 999.9 s, 9999 s, 99 min 59 s, 999.9 min, 99 h 59 min, 999.9 h (selected by DIP switch) Addition (UP)/Subtraction (DOWN) (2 directions selectable by DIP switch) A (Power ON delay 1), A2 (Power ON delay 2), B (Signal ON delay), C (Signal OFF delay), D (Pulse...

Open the catalog to page 3
lt4h-catalog - 4

LT4H/-L (units: mm inch) Tolerance: ±1.0 ±.039 Dimensions • LT4H digital timer Screw terminal type (Flush mount) Ⅺ48 Ⅺ1.890 Pin type (Flush mount/Surface mount) RESET LOCK • Dimensions for embedded installation (with adapter installed) Screw terminal type Pin type Rubber gasket ATC18002 (supplied) Mounting frame for flush mount AT8-DA4 (supplied) Mounting frame 8-pin type for flush mount (8p cap AD8-RC AT8-DA4 (supplied) sold separately) 11-pin type (11p cap AT8-DP11 sold separately) Rubber gasket ATC18002 (supplied) • Dimensions for front panel installations The standard panel cut-out...

Open the catalog to page 4
lt4h-catalog - 5

LT4H/-L Setting the operation mode, time range, and time Setting procedure 1) Setting the operation mode and time range Set the operation mode and time range with the DIP switches on the side of the LT4H timer. Table 1: Setting the operation mode Operation mode Minimum input reset, start, and stop signal width 5 Time delay direction Addition Subtraction 6 Time range Refer to table 2 7 8 * The 8-pin type does not have the stop input, so that the dip switch can be changed over between reset and start inputs. The signal range of the lock input is fixed (minimum 20 ms). Table 2: Setting the...

Open the catalog to page 5
lt4h-catalog - 6

Operation mode Operation type Time chart Notes: 1) Each signal input (start, reset, stop, and lock) is applied by shorting their input terminal to the common terminal (terminal © for the 8-pin type, terminal @ for the 11-pin type, and terminal [U for the screw terminal type). 2) The 8-pin type does not have a stop input or lock input. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

Open the catalog to page 6
lt4h-catalog - 7

Operation type Time chart Pulse One-shot Notes: 1) Each signal input (start, reset, stop, and lock) is applied by shorting their input terminal to the common terminal (terminal © for the 8-pin type, terminal @ for the 11-pin type, and terminal [§] for the screw terminal type). 2) The 8-pin type does not have a stop input or lock input. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

Open the catalog to page 7
lt4h-catalog - 8

DIN 48 SIZE DIGITAL TIMER 11-pin type Screw terminal type RoHS Directive compatibility information http://www.nais-e.com/ 1. Wide time range The operation time range covers from 0.01 sec. to 9999 hours. The individual setting can be performed on each of 1 and 2 timers. 99.99s 99min59s 99h59min 999.9s 999.9min 999.9h 9999s 9999h 2. Bright and Easy-to-Read Display A brand new bright 2-color back light LCD display. The easy-to-read screen in any location makes checking and setting procedures a cinch. 3. Simple Operation Seesaw buttons make operating the unit even easier than before. 4. Short...

Open the catalog to page 8
lt4h-catalog - 9

LT4H-W Part names T1/T2 Operation display Lock indicator Time units display Up keys Set/Lock switch Controlled output indicator Reset switch Elapsed time display Display for change-over between T1/T2 settings (Subtraction elapsed time display) Down keys Fourth digit (Same for 8-pin and screw terminal type) First digit Specifications Type Item Rated operating voltage Rated frequency Rated power consumption Rated control capacity Time range Time counting direction Rating Operation mode Start/Reset/Stop input Lock input Input signal Indication Power failure memory method Operating time...

Open the catalog to page 9

All Panasonic Electric Works Corporation of America catalogs and technical brochures

  1. SP-Cap

    32 Pages

  2. TQC series

    7 Pages

  3. ZF-A series

    9 Pages

  4. ZC-A series

    9 Pages

  5. PAN1780‑AT

    37 Pages

  6. LD-P RELAYS

    8 Pages

  7. ERJH2CF1R33X

    7 Pages

  8. ZKU series

    9 Pages

  9. LQ RELAYS

    9 Pages

  10. SF-M RELAYS

    8 Pages

  11. PhotoMOS HF

    14 Pages

  12. ZU series

    9 Pages

  13. ZSU series

    9 Pages

  14. ZSU-A series

    9 Pages

  15. PAN1781

    23 Pages

  16. PAN9520 ETU

    35 Pages

  17. PAN9520

    36 Pages

  18. HE-V RELAYS

    5 Pages

  19. PAN1026A

    2 Pages

  20. DP3 Catalog

    14 Pages

  21. AQ-K Catalog

    3 Pages

  22. AQ-F Catalog

    5 Pages

  23. ABS Catalog

    11 Pages

  24. A4F Catalog

    9 Pages

  25. EX-L200 series

    12 Pages

  26. LP-400 series

    16 Pages

  27. HL-G1 Series

    16 Pages

  28. A35S Catalog

    8 Pages

  29. a4-catalog

    175 Pages

  30. e-catalog

    81 Pages

  31. kw-catalog

    28 Pages

  32. lh2h-catalog

    8 Pages

  33. kt-catalog

    16 Pages

  34. hl-azh-catalog

    15 Pages

  35. pm5s-catalog

    7 Pages

  36. pmh-catalog

    7 Pages

  37. pv310-catalog

    12 Pages

  38. S1DXM

    30 Pages

  39. SF4B-G

    6 Pages

  40. TH (Sensor)

    16 Pages

  41. UJ20

    11 Pages

  42. VL-T

    19 Pages

  43. LP-S500W

    12 Pages

  44. HL (AZH)

    30 Pages

  45. GT21C

    24 Pages

  46. FX-500

    20 Pages

  47. FM-200

    12 Pages

  48. EQ-500

    12 Pages

  49. DPC-DPH 100

    22 Pages

  50. DL (AZD1)

    23 Pages

  51. Lighting

    43 Pages

  52. AX40

    12 Pages

  53. VIC100

    6 Pages

  54. KW Catalog

    17 Pages

  55. LH2H Catalog

    29 Pages

  56. LCH Catalog

    34 Pages

  57. KT Catalog

    20 Pages

  58. AZ5 Catalog

    22 Pages

  59. LT4H Catalog

    39 Pages

  60. GN Catalog

    10 Pages