light curtain sf2b series catalog - 36 Pages

Add to MyDirectIndustry favorites
light curtain sf2b series catalog

Catalog excerpts

SERIES > Conforming toOSHA / ANSI Conforming to Machine Directive & EMC Directive Approved Listing dead zone Environmental resistance >

 Open the catalog to page 1

SF2B > SERIES International standard safety design size="-1">

 Open the catalog to page 2

SF2B series helps to make safety measures easier and plays an indispensable part in creating a safe working environment. In addition to compliance with the IEC 61496 (Type 2) international safety standard, excellent performance with good ease of use is provided in a wide variety of applications from compact machinery installed side-by-side to save space, through to large equipment for long-range, wide-area sensing. The Newconcept > Thickness 26 mm 1.024 inwhen setting up Cables can be routed freely 24 mm0.945 in Unit length = Protective height Maximum sensing width (Protective height)...

 Open the catalog to page 4

Two types are available for different minimum sensing object sizes. Furthermore, sub-sensors for serial connection (optional) can be used to connect up to three sets of light curtains (up to a total maximum of 128 beam channels; however the SF2B-A allows up to 96 beam channels when two sets are connected, and up to 64 beam channels when three sets are connected). Hand protection type SF2B-H Arm / Foot protection type SF2B-A Minimum sensing object " 27 mm " 1.063 in Minimum sensing object " 47 mm " 1.850 in (20 mm 0.787 in beam pitch) (40 mm 1.575 in beam pitch) Serial connection of up to...

 Open the catalog to page 5

Internal unit The inner unit is protected by a cylindri-cal inner case. The seams such as unit and lens surfaces have been greatly reduced, so that particles such as oil mists and dust are prevented from getting in.[The protective structure is IP65 (IEC).] Inner caseProtective caseEnd unit > m The photograph shows a cut-away model. SF2B > SERIES Improved reliability size="-1">

 Open the catalog to page 6

m Extraneous Light Check & Avoid > Front protection cover >

 Open the catalog to page 7

The system constantly checks the light curtain for problems such as incorrect cable wiring, disconnection and short-circuits, and also for internal circuit problems and incoming light problems. If a problem should occur, details of the error appear on the digital display. The error details can be checked at a glance without the inconvenience of the previous method of counting the number of LED blinks, so that smooth support is possible if problems occur at startup and during maintenance operations, even if assistance is given via telephone. > Normal operation Breaking out error > Digital...

 Open the catalog to page 8

New concept Adapter cables and adapter mountin brackets are available to make it much easier to replace the wiring when changing over from SF2-A series or SF2-N series light curtains or NA40 series or SF1-N series area sensors to a new series (Note). Mounting holes and control circuit connector cables do not need to be changed. There is no need to use spare parts for previous models, so registration numbers can be reduced to SF2B series components only. > Note: For details, please contact our office. Replacing old SF2-A light curtain Replacing old SF1-N area sensor > Same mounting bracket...

 Open the catalog to page 9

Alarm output Output circuit OSSD1 (control output) There is a large difference between Type 2 light curtains and area sensors in the reliability of OFF operation when a problem occurs. Alarmoutput Control circuitMonitoringsection (CPU) Control circuit Output circuit OSSD2 (control output) ● Conceptual diagram of light curtain output > Receiving circuit Emitting circuit Output monitor > CheckCheckCheck Monitoringsection (CPU) Test input CPUTr > 1 Tr > 2 0 VControloutput (OSSD) Doubled output transistor Output problem monitoring via CPU Synchronization line Output turns OFF when a problem...

 Open the catalog to page 10

MonitorContactor, etc.Safety relay,etc. > ● Safety relay Matsushita Electric Works Ltd.SF relay > Monitor,etc. Uses external device monitoring function > Reduced component costs Note: Construct a separate reset input circuit. ● Miniature contactor Matsushita Electric Works Ltd. Reset input PC-5 series > Monitor Note: Contact the manufacturers for details on the recommended products. > Less processing Contactor, etc. Monitor,etc. Uses SF-C11 connectable control unit > Flat-tipped screwdriverLead wire Ferrule (sleeve) terminal(Please arrange separately.) > Release button > Lead wire insertion...

 Open the catalog to page 11

(Optional, use for connect in series) > (Optional, use for connect in series) > m (Optional, use for cable extension) > 27 mm Hand protection type " When using the adapter cable > 641,272 50.079 SF2B-CB05-B :0.2 to 5 m > Beam pitchProtective height 6 mm 20792 31.181 > Beam pitchProtective height 0.2 to 13 m > 40 mm 1.575 in 24952 37.480 0.656 to 42.651 ft > 47 mm " When using the adapter cable > 281,112 43.779 > Arm / Foot protection type 481,912 75.275 Notes: 1) The operating rangeђ is the possible setting distance between the emitter and the receiver. The light curtain can detect less...

 Open the catalog to page 12

Cable length: 3 m 9.843 ft Used for connecting to the light curtain and to other cables or the Net weight 370 g approx. (2 cables) SF-C13 control unit. Two cables per set for emitter and receiver, Cable outer diameter: > " 6 mm " 0.236 in Cable length: 7 m 22.966 ft Cable color: Gray (for emitter), Gray with black line (for receiver) > Net weight 820 g approx. (2 cables) The min. bending radius: R6 mm R0.236 in > Cable length: 0.5 m 1.640 ft Net weight 95 g approx. (2 cables) Used for connecting to the light curtain and to an extension cable or the SF-C11 control unit. > 3 Cable length: 5 m...

 Open the catalog to page 14

The sub-sensors for series connection are PNP / NPN types. Furthermore, they cannot simply be used by themselves. Always be sure to use them in combination with light curtains. > (Note 2) 8168 6.614 Emitter: 20 mA or less > 20392 15.433 Receiver: 35 mA or less > Beam channel No. 6 mm 36712 28.031 Receiver: 55 mA or less 0.656 to 42.651 ft > pitch) 40792 31.181 Emitter: 40 mA or less When using SF2B-CB05-B > 48952 37.480 Receiver: 65 mA or less conversion cable at light curtain: 0.2 to 5 m > Hand protection typeMin. sensing object 641,272 50.079 Receiver: 85 mA or less > Beam pitchProtective...

 Open the catalog to page 15

All Panasonic Electric Works Corporation of America catalogs and technical brochures

  1. Energy Solutions

    15 Pages

  2. HE-V RELAYS

    5 Pages

  3. PAN1026A

    2 Pages

  4. DP3 Catalog

    14 Pages

  5. AQ-K Catalog

    3 Pages

  6. AQ-F Catalog

    5 Pages

  7. ABS Catalog

    11 Pages

  8. A4F Catalog

    9 Pages

  9. EX-L200 series

    12 Pages

  10. LP-400 series

    16 Pages

  11. HL-G1 Series

    16 Pages

  12. A35S Catalog

    8 Pages

  13. a4-catalog

    175 Pages

  14. e-catalog

    81 Pages

  15. kw-catalog

    28 Pages

  16. th-meter-catalog

    18 Pages

  17. lh2h-catalog

    8 Pages

  18. kt-catalog

    16 Pages

  19. hl-azh-catalog

    15 Pages

  20. ql-az4-catalog

    6 Pages

  21. vl-az8-catalog

    8 Pages

  22. lt4h-catalog

    16 Pages

  23. pm5s-catalog

    7 Pages

  24. pmh-catalog

    7 Pages

  25. pv310-catalog

    12 Pages

  26. S1DXM

    30 Pages

  27. SF4B-G

    6 Pages

  28. TH (Sensor)

    16 Pages

  29. UJ20

    11 Pages

  30. VL-T

    19 Pages

  31. LightPix AE20

    8 Pages

  32. LP-S500W

    12 Pages

  33. HL (AZH)

    30 Pages

  34. GT21C

    24 Pages

  35. FX-500

    20 Pages

  36. FM-200

    12 Pages

  37. EQ-500

    12 Pages

  38. DPC-DPH 100

    22 Pages

  39. DL (AZD1)

    23 Pages

  40. Lighting

    43 Pages

  41. AX40

    12 Pages

  42. VIC100

    6 Pages

  43. CX-400 Version 2

    24 Pages

  44. KW Catalog

    17 Pages

  45. LH2H Catalog

    29 Pages

  46. LCH Catalog

    34 Pages

  47. KT Catalog

    20 Pages

  48. AZ5 Catalog

    22 Pages

  49. LT4H Catalog

    39 Pages

  50. A100/200 Catalog

    26 Pages

  51. UJ30/35 Catalog

    12 Pages

  52. LP-F10 Catalog

    4 Pages

  53. LP-200 Catalog

    6 Pages

  54. NA1-11 Catalog

    8 Pages

  55. GN Catalog

    10 Pages