Catalog excerpts
DIGITAL PRESSURE SENSOR RoHS compatible Single axis type Dual Display Direct operation
Open the catalog to page 1Single axis type Free-turning structure* Direct installation using a hexagonal wrench Hexagonal wrench installation * Piercing mechanism from integrated shape of the pressure port and the mounting bolts Industry rst! The hexagonal wrench installation makes a break through in installation method. Previous problem Difculty of installation using a spanner Spanner cannot be turned Obstacle Spanner does not t! Wasted working space
Open the catalog to page 2Dual display + Direct setting <Taking from the operations of the DP-100 series> Current value Main display Threshold value Because direct Dual display direct setting makes operation much more novel Previous problem Difficulty with only one display Write down current value threshold value Dual display direct setting Just press the button
Open the catalog to page 31 Breakthrough construction Hexagonal wrench installation Industry rst* * Based on research conducted by SUNX as of March 2008. Previous problem DPH-100 Spanner is difcult to hold! Turns minimally from above! (Obstructed by oor surface) Obstac Previous problem Large space needed to turn the spanner! le Previous problem Spanner cannot be turned! Obstructions can be avoided and installation from above can be done much more easily using a hexagonal wrench. This also eliminates wasted installation space and contributes to a smaller installation footprint. 2 Flexible design! Sensor heads can be...
Open the catalog to page 43 Quick maintenance Industry rst* One sensor can be removed from between others 4 Previous models 3 * Based on research conducted by SUNX as of March 2008. DPH-100 2 Remove and install the required sensor head directly. 1 Spanner does not t! It cannot be turned either! To remove 3, you have to remove the sensors in order starting from 1. During maintenance, the sensor head needed to be removed can be easily removed from directly above. 4 Mounting space-saving Space saving during installation 5 Easy adjustment Sensor heads can be turned after installation Industry thinnest* * Based on...
Open the catalog to page 5Industry fastest* Reduced tact time Suitable for high-speed applications Industry fastest response time contributes to even greater productivity. * Based on research conducted by SUNX as of March 2008. Industry fastest at 500 μs Setting is smooth and easy The controller’s setting operation mode has a 3-level conguration to suit the frequency of use RUN mode The setting levels are clearly separated into “RUN mode” for operation settings that are carried out daily, “MENU SETTING mode” for basic settings, and “PRO mode” for special and detailed setting. These make setting operations easy to...
Open the catalog to page 6Initial setting work is reduced Copy function reduces man-hours and human error Controllers can be connected to a master controller one by one, and a copy of the setting details for the master controller can be transmitted as data to the slave controllers. If making the same settings for multiple controllers, this prevents setting errors from occurring with the other controllers and also reduces the number of changes required to instruction manuals when equipment designs are changed. Setting man-hours are reduced and controller setting time is much shortened For example Copying via copy...
Open the catalog to page 7Other useful functions 1 model to suit a wide variety of applications DPC-100 original functions Inputs Outputs Comparative output 1 Remote zero-adjustment input Auto-reference input Comparative output 2 Selection Selection Analog voltage output 1 to 5 V Analog current output 4 to 20 mA Equipped with independent two output and three output modes ● Vacuum breakdown can also be checked during suction applications! Comparative output 1 EASY mode Comparative output 2 EASY mode ON This mode is used for comparative output ON / OFF control. H (Hysteresis) P 0 Comparative ON output OFF H: Fixed...
Open the catalog to page 8Equipped with auto-reference / remote zero-adjustment functions, More precise pressure management is possible with a minimum of effort If the reference pressure of the device changes, the autoreference function partially shift the comparative output judgment level by the amount that the reference pressure shifts, and the remote zero-adjustment function can reset the display value to zero via external input. These functions are ideal for places where the reference pressure uctuates wildly, or where ne settings are desired. Without auto-reference and remote zero-adjustment functions...
Open the catalog to page 9Other useful functions Sub display can be customized Setting details can be understood at a glance The sub display can be set to indicate any other desired values or letters apart from the threshold value. This eliminates the need for tasks such as afxing a label to the device to indicate the normal pressure value. The DPC-100 setting details appear in the digital display. Because the settings are in numeric form that can be easily understood, it is useful for times such as when receiving technical support by telephone. What are the check codes for the setting? 2nd digit: Setting status for...
Open the catalog to page 10Installation is also easy! Tight installation to panels is possible An exclusive mounting bracket (MS-DP1-2) that is suitable for 1 to 6 mm 0.039 to 0.236 in panel thickness is available. An exclusive mounting bracket (MS-DP1-6) that supports tight installation is available Space saving can also be obtained if an L-shaped mounting bracket is used. Tight installation is possible Floor mounting Ceiling mounting Tight installation is possib le Takes up much less space Power supply cable can be connected with one-touch connection The accessory connector attached cable (2 m 6.562 ft) can be...
Open the catalog to page 11PRODUCT CONFIGURATION Connector (e-CON) Sensor head Power supply connector Controller Connector attached cable ORDER GUIDE Sensor heads Type Appearance Rated pressure range Model No. Pressure port DPH-101 DPH-101-M3 Flexible cable type Vacuum pressure DPH-10□(-R) 0 to –101.0 kPa Flexible cable type R1/8 male thread + M5 female thread M3 male thread M5 male thread DPH-102 R1/8 male thread + M5 female thread DPH-102-M5 M5 male thread R1/8 male thread + M5 female thread M3 male thread DPH-103-M5 M5 male thread DPH-103-R R1/8 male thread + M5 female thread DPH-103-M3-R 0 to +1.000 MPa DPH-101-R...
Open the catalog to page 12All Panasonic Electric Works Corporation of America catalogs and technical brochures
-
SP-Cap
32 Pages
-
TQC series
7 Pages
-
ZF-A series
9 Pages
-
EEH-ZE Series
9 Pages
-
ZC-A series
9 Pages
-
EEH-AZA1E151B
9 Pages
-
PAN1780‑AT
37 Pages
-
LD-P RELAYS
8 Pages
-
ERJH2CF1R33X
7 Pages
-
R35K (0.35 mm pitch
10 Pages
-
ZKU series
9 Pages
-
LQ RELAYS
9 Pages
-
SF-M RELAYS
8 Pages
-
PhotoMOS HF
14 Pages
-
ZU series
9 Pages
-
ZSU series
9 Pages
-
ZSU-A series
9 Pages
-
PAN1781
23 Pages
-
PAN9520 ETU
35 Pages
-
PAN9520
36 Pages
-
Energy Solutions
15 Pages
-
Line Card Catalog
68 Pages
-
HE-V RELAYS
5 Pages
-
PAN1026A
2 Pages
-
Light touch switch
14 Pages
-
ETQ Series Power Choke CoiLs
1 Pages
-
DP3 Catalog
14 Pages
-
AQY DIP Flat Package Catalog
4 Pages
-
AQW DIP 2 Form A Catalog
4 Pages
-
AQV SOP Form B Catalog
4 Pages
-
AQ-K Catalog
3 Pages
-
AQ-F Catalog
5 Pages
-
ABS Catalog
11 Pages
-
A4F Catalog
9 Pages
-
EX-L200 series
12 Pages
-
LP-400 series
16 Pages
-
HL-G1 Series
16 Pages
-
D-Imager Catalog
2 Pages
-
A35S Catalog
8 Pages
-
a4-catalog
175 Pages
-
e-catalog
81 Pages
-
lighting-relays-catalog
6 Pages
-
kw-catalog
28 Pages
-
th-meter-catalog
18 Pages
-
lh2h-catalog
8 Pages
-
kt-catalog
16 Pages
-
hl-azh-catalog
15 Pages
-
ql-az4-catalog
6 Pages
-
vl-az8-catalog
8 Pages
-
lt4h-catalog
16 Pages
-
pm5s-catalog
7 Pages
-
pmh-catalog
7 Pages
-
pv310-catalog
12 Pages
-
lightpix-ae20-catalog
8 Pages
-
S1DXM
30 Pages
-
SF4B-G
6 Pages
-
TH (Sensor)
16 Pages
-
UJ20
11 Pages
-
VL-T
19 Pages
-
LightPix AE20
8 Pages
-
LP-S500W
12 Pages
-
HL (AZH)
30 Pages
-
GT21C
24 Pages
-
FX-500
20 Pages
-
FM-200
12 Pages
-
EQ-500
12 Pages
-
DL (AZD1)
23 Pages
-
Lighting
43 Pages
-
AX40
12 Pages
-
VIC100
6 Pages
-
Programmable Controller FP2
20 Pages
-
FPSIGMA Programmable Controller
20 Pages
-
CX-400 Version 2
24 Pages
-
KW Catalog
17 Pages
-
LH2H Catalog
29 Pages
-
LCH Catalog
34 Pages
-
KT Catalog
20 Pages
-
AZ5 Catalog
22 Pages
-
LT4H Catalog
39 Pages
-
A100/200 Catalog
26 Pages
-
UJ30/35 Catalog
12 Pages
-
LP-F10 Catalog
4 Pages
-
LP-200 Catalog
6 Pages
-
NA1-11 Catalog
8 Pages
-
GN Catalog
10 Pages
-
Data Logger Light Catalog
4 Pages