Digital Pressure Sensor with Auto-reference Function Digital Auto reference PRESSURE SENSORS High accuracy sensing at all times with autoreference function * Passed the UL 991 Environment Test * UL 61010C-1 compatible, Passed the UL 991 Environment Test based on SEMI S2-0200. [Category applicable for semiconductor manufacturing: TWW2, Process Equipment] [Applicable standards: UL 61010C-1] [Additional test / evaluation standards as per intended use: UL991, SEMI S2-0200] Example of air-leak test Threshold level Auto-reference function follows reference pressure changes Reference pressure • Unaffected by changes in reference pressure By an external signal, the set (threshold) values are corrected by being shifted by an amount equal to the pressure change. Hence, judgment by the sensor is as accurate as before the reference pressure change. This function is extremely suitable in places having intense variations in the reference pressure or where fine settings are required. Reference pressure Before reference pressure change Reference pressure Reference pressure Pressure sensor not incorporating auto-reference function After reference pressure change • Total cost reduction Till now...one sensor was required for each suction nozzle Since the threshold level differs with the suction nozzle, a sensor was required for each suction nozzle, increasing the cost significantly. ( Atmospheric ) pressure Suction nozzle for chip components For chip components Vacuum Before suction Suction OK Suction NG Suction over In case of DP3...operation efficiency UP! Since the threshold level can be automatically changed by the auto-reference function, two suction nozzles can be used, alternately, with one sensor. DP3-80 Suction nozzle for trimmers Auto-reference input Incorporates auto-reference function Threshold level for suction nozzle for trimmers Threshold level for suction nozzle for chip components Electromagnetic valve

Open the catalog to page 1
DP3 Catalog - 2

Hysteresis Hysteresis Set Value 1 Set Value 2 Set Value 3 Set Value 4 (P-1) (P-2) (P-3) (P-4) High pressure (Positive pressure type) High vacuum (Vacuum pressure type) Set Value 1 Set Value 2 Set Value 3 Set Value 4 (P-1) (P-2) (P-3) (P-4) High pressure (Positive pressure type) High vacuum (Vacuum pressure type) Hysteresis: 1 digit (2 digits when using psi unit) Note: The auto-reference function acts only on Set Value 3 (P-3) and Set Value 4 (P-4) of Comparative Output 2. Note: The auto-reference function acts only on Set Value 3 (P-3) and Set Value 4 (P-4) of Comparative Output 2. Optimum...

Open the catalog to page 2
DP3 Catalog - 3

PRESSURE SENSORS DP5/DPH Head-separated DP3 APPLICATIONS Confirmation of chip component suction The auto-reference function can compensate for the difference in suction levels due to suction nozzle separation distance. The vacuum type can be mounted close to the chip mounter suction head since it weighs only 70 g. Air-leak test for PET bottles Leak test mode, which is an output mode optimally suitable for an air-leak test, has been incorporated. It can reliably detect even a small air-leak. Because of the auto-reference function, it is safe even if the filling pressure varies. DP3-41...

Open the catalog to page 3
DP3 Catalog - 4

OPTIONS Sensor mounting bracket MS-DPX Sensor mounting bracket (For standard type) Description Mounting bracket for standard type Two M4 (length 6 mm 0.236 in) pan head screws and two spring washers are attached. Back angled mounting bracket for standard type Two M4 (length 6 mm 0.236 in) pan head screws and two spring washers are attached. Changes the pressure port from female thread [Rc (PT) 1/8] to male thread [R (PT) 1/8]. Panel mounting bracket (For standard type) It can be used for mounting on a panel (1 to 3.2 mm 0.039 to 0.126 in thick). Front protection cover (For standard type) It...

Open the catalog to page 4
DP3 Catalog - 5

PRESSURE SENSORS DP5/DPH Head-separated DP4 Type Item Vacuum pressure ‫ 101מ‬kPa type Standard Light weight DP3-20 Rated pressure range Set pressure range (Note 1) Settable range (Note 2) Applicable fluid kPa, kgf/cm2, bar, psi, mmHg, inHg Current consumption Output modes Hysteresis DC-12 or DC-13 Equipped with 4 types of modes: hysteresis mode, window comparator mode, leak test mode, forced output mode (selectable by key operation) 1 digit (however, variable in hysteresis mode, variable for Comparative Output 1 only when using leak test mode, and 2 digits when using psi unit) Within‫ %...

Open the catalog to page 5
DP3 Catalog - 6

I/O CIRCUIT AND WIRING DIAGRAMS Wiring diagram Color code (Brown)‫ם‬V Auto-reference (Pink) input (Note) (Black) Comparative Output 1 Internal circuit Load Load 100 mA max. (White) Comparative Output 2 (Blue) 0 V Users’ circuit Note: If you do not use the auto-reference input (pink), always connect it to ‫ם‬V (brown). Sensor circuit PRESSURE SENSORS Brown Load Pink Symbols ... D: Reverse supply polarity protection diode ZD1, ZD2 : Surge absorption zener diode Tr 1 , Tr 2 : NPN output transistor Operation • If setting is impossible even with pressing the MODE key, verify whether the...

Open the catalog to page 6
DP3 Catalog - 7

PRECAUTIONS FOR PROPER USE All models Functional description PRESSURE SENSORS Error messages • When an error occurs, take the following corrective action. Error message Overcurrent due to short- Switch off the power supply circuit. and check the load. Applied pressure at the Pressure is being applied pressure port should be during zero-point adjust- brought to atmospheric presment. sure and zero-point adjustment should be done again. Positive pressure type Lights up when Comparative Output 1 is ON. Comparative Output 3 2 operation indicator (Green) Lights up when Comparative Output 2 is ON....

Open the catalog to page 7
DP3 Catalog - 8

Setting • If key-protect has been set, make sure to release key-protect before operating the keys. (Please refer to ‘Key-protect function’ on p.817 for the procedure.) • Set Value 1 to 4 (P-1 to P-4) can be made common for all the output modes. • In the positive pressure type sensor, Set Value 2 (P-2) and Set Value 4 (P-4) can be set only towards the high pressure side with respect to Set Value 1 (P-1) and Set Value 3 (P-3), respectively. In the vacuum pressure type sensor, Set Value 2 (P-2) and Set Value 4 (P-4) can be set only towards the high vacuum side with respect to Set Value 1 (P-1)...

Open the catalog to page 8

All Panasonic Electric Works Corporation of America catalogs and technical brochures

  1. SP-Cap

    32 Pages

  2. TQC series

    7 Pages

  3. ZF-A series

    9 Pages

  4. ZC-A series

    9 Pages

  5. PAN1780‑AT

    37 Pages

  6. LD-P RELAYS

    8 Pages

  7. ERJH2CF1R33X

    7 Pages

  8. ZKU series

    9 Pages

  9. LQ RELAYS

    9 Pages

  10. SF-M RELAYS

    8 Pages

  11. PhotoMOS HF

    14 Pages

  12. ZU series

    9 Pages

  13. ZSU series

    9 Pages

  14. ZSU-A series

    9 Pages

  15. PAN1781

    23 Pages

  16. PAN9520 ETU

    35 Pages

  17. PAN9520

    36 Pages

  18. HE-V RELAYS

    5 Pages

  19. PAN1026A

    2 Pages

  20. AQ-K Catalog

    3 Pages

  21. AQ-F Catalog

    5 Pages

  22. ABS Catalog

    11 Pages

  23. A4F Catalog

    9 Pages

  24. EX-L200 series

    12 Pages

  25. LP-400 series

    16 Pages

  26. HL-G1 Series

    16 Pages

  27. A35S Catalog

    8 Pages

  28. a4-catalog

    175 Pages

  29. e-catalog

    81 Pages

  30. kw-catalog

    28 Pages

  31. lh2h-catalog

    8 Pages

  32. kt-catalog

    16 Pages

  33. hl-azh-catalog

    15 Pages

  34. lt4h-catalog

    16 Pages

  35. pm5s-catalog

    7 Pages

  36. pmh-catalog

    7 Pages

  37. pv310-catalog

    12 Pages

  38. S1DXM

    30 Pages

  39. SF4B-G

    6 Pages

  40. TH (Sensor)

    16 Pages

  41. UJ20

    11 Pages

  42. VL-T

    19 Pages

  43. LP-S500W

    12 Pages

  44. HL (AZH)

    30 Pages

  45. GT21C

    24 Pages

  46. FX-500

    20 Pages

  47. FM-200

    12 Pages

  48. EQ-500

    12 Pages

  49. DPC-DPH 100

    22 Pages

  50. DL (AZD1)

    23 Pages

  51. Lighting

    43 Pages

  52. AX40

    12 Pages

  53. VIC100

    6 Pages

  54. KW Catalog

    17 Pages

  55. LH2H Catalog

    29 Pages

  56. LCH Catalog

    34 Pages

  57. KT Catalog

    20 Pages

  58. AZ5 Catalog

    22 Pages

  59. LT4H Catalog

    39 Pages

  60. GN Catalog

    10 Pages