cad

AQS High Capacity Voltage Sensitive Catalog
3Pages

{{requestButtons}}

Catalog excerpts

AQS High Capacity Voltage Sensitive Catalog - 1

GU SOP 1 Form A High Capacity Voltage-sensitive (AQY212FG2S) Space-saving SOP4-pin high capacity type with built-in input registor GU SOP 1 Form A High Capacity Voltage-sensitive (AQY212FG2S) RoHS compliant 3. Continuous load current of 1.25A This miniature SOP type controls 1.25A/ 60V load. 1. Built-in input resistor means less man-hours when mounting The voltage-sensitive type, which eliminates the need to mount an external input resistor, is now available in a small package (recommended input voltage is 5 V). Man-hours spent mounting external input resistors are cut and board designing is simplied. 2. Saves space on PC board Since the small package size remains the same while including a built-in input resistor, space on the PC board is saved. This makes it easier to incorporate space savings when designing miniature devices. TYPICAL APPLICATIONS 1. Measuring and testing equipment Semiconductor testing equipment, Probe cards, Datalogger, Board tester and other testing equipment. 2. Telecommunication, Broadcasting, and Medical equipment Existing way of mounting external resistors With resistors built in Space saved *Above is in case of SSOP. TYPES Output rating*1 Load voltage AC/DC dual use Packing quantity Load current Tube packing style Tape and reel packing style Picked from the Picked from the 1/2-pin side 3/4-pin side AQY212FG2SX 1 tube contains: 100 pcs. 1 batch contains: 2,000 pcs. Notes: *1 Indicate the peak AC and DC values. *2 For space reasons, only “212FG2” is marked on the product. The three initial letters of the part number “AQY”, the package (SOP) indicator “S”, and the packing style indicator “X” or “Z” have been omitted. RATING 1. Absolute maximum ratings (Condition: ambient temperature 25°C 77°F) Item Input voltage Input reverse voltage Input Power dissipation Load voltage (peak AC) Load current Output Peak load current Power dissipation Total power dissipation I/O isolation voltage Operating temperature Storage temperature Symbol VIN VRIN Pin VL IL Ipeak Pout PT Viso Topr Tstg Panasonic Corporation Automation Controls Business Unit

Open the catalog to page 1
AQS High Capacity Voltage Sensitive Catalog - 2

GU SOP 1 Form A High Capacity Voltage-sensitive (AQY212FG2S) 2. Electrical characteristics (Condition: ambient temperature 25°C 77°F) Item Operate voltage Input Turn off voltage Input current On resistance Initial I/O isolation resistance Output capacitance Off state leakage current Turn on time* Turn off time* Transfer characteristics Maximum operating frequency Cout ILeak Ton Toff Ciso *Turn on/Turn off time RECOMMENDED OPERATING CONDITIONS Please obey the following conditions to ensure proper device operation and resetting. Item Input voltage ■ For Dimensions. ■ For Schematic and Wiring...

Open the catalog to page 2
AQS High Capacity Voltage Sensitive Catalog - 3

GU SOP 1 Form A High Capacity Voltage-sensitive (AQY212FG2S) 4. Turn off time vs. ambient temperature characteristics 5. Turn on voltage vs. ambient temperature characteristics 6. Turn off voltage vs. ambient temperature characteristics Input voltage: 5V; Load voltage: 10V (DC); Continuous load current: 100mA (DC) Load voltage: 10V (DC); Continuous load current: 100mA (DC) Load voltage: 10V (DC); Continuous load current: 100mA (DC) 4 7. Input current vs. ambient temperature characteristics 8. Current vs. voltage characteristics of output at MOS portion Measured portion: between terminals 3...

Open the catalog to page 3

All Panasonic Electric Works Corporation of America catalogs and technical brochures

  1. SP-Cap

    32 Pages

  2. TQC series

    7 Pages

  3. ZF-A series

    9 Pages

  4. ZC-A series

    9 Pages

  5. PAN1780‑AT

    37 Pages

  6. LD-P RELAYS

    8 Pages

  7. ERJH2CF1R33X

    7 Pages

  8. ZKU series

    9 Pages

  9. LQ RELAYS

    9 Pages

  10. SF-M RELAYS

    8 Pages

  11. PhotoMOS HF

    14 Pages

  12. ZU series

    9 Pages

  13. ZSU series

    9 Pages

  14. ZSU-A series

    9 Pages

  15. PAN1781

    23 Pages

  16. PAN9520 ETU

    35 Pages

  17. PAN9520

    36 Pages

  18. HE-V RELAYS

    5 Pages

  19. PAN1026A

    2 Pages

  20. DP3 Catalog

    14 Pages

  21. AQ-K Catalog

    3 Pages

  22. AQ-F Catalog

    5 Pages

  23. ABS Catalog

    11 Pages

  24. A4F Catalog

    9 Pages

  25. EX-L200 series

    12 Pages

  26. LP-400 series

    16 Pages

  27. HL-G1 Series

    16 Pages

  28. A35S Catalog

    8 Pages

  29. a4-catalog

    175 Pages

  30. e-catalog

    81 Pages

  31. kw-catalog

    28 Pages

  32. lh2h-catalog

    8 Pages

  33. kt-catalog

    16 Pages

  34. hl-azh-catalog

    15 Pages

  35. lt4h-catalog

    16 Pages

  36. pm5s-catalog

    7 Pages

  37. pmh-catalog

    7 Pages

  38. pv310-catalog

    12 Pages

  39. S1DXM

    30 Pages

  40. SF4B-G

    6 Pages

  41. TH (Sensor)

    16 Pages

  42. UJ20

    11 Pages

  43. VL-T

    19 Pages

  44. LP-S500W

    12 Pages

  45. HL (AZH)

    30 Pages

  46. GT21C

    24 Pages

  47. FX-500

    20 Pages

  48. FM-200

    12 Pages

  49. EQ-500

    12 Pages

  50. DPC-DPH 100

    22 Pages

  51. DL (AZD1)

    23 Pages

  52. Lighting

    43 Pages

  53. AX40

    12 Pages

  54. VIC100

    6 Pages

  55. KW Catalog

    17 Pages

  56. LH2H Catalog

    29 Pages

  57. LCH Catalog

    34 Pages

  58. KT Catalog

    20 Pages

  59. AZ5 Catalog

    22 Pages

  60. LT4H Catalog

    39 Pages

  61. GN Catalog

    10 Pages