Overview: The PM880 is a portable, intrinsically safe hygrometer designed for industrial moisture measurement. It features a compact, lightweight design with a large LCD display for moisture readings in various units such as dew point, ppmv, and lb/MMSCF. The device includes a rechargeable battery pack, making it suitable for field use.
Features:
  • Hand-held and portable with IP67 rating.
  • Large graphic display and internal data logger.
  • Optional IrDA communication with PC.
  • Stores up to 60 log/site files.
  • Compatible with all Panametrics moisture probes.
  • Comes with a carrying case and various accessories.
Applications: The PM880 is used for measuring moisture in gases and non-aqueous liquids across various industries, including natural gas, chemical and petrochemical gases, air separation plants, and more.
Technical Specifications:
  • Single channel with dimensions of 9.4 x 5.5 x 1.5 inches and a weight of 2.5 lb for electronics.
  • Enclosure Type 4X, IP67.
  • Data logging capacity for over 100,000 moisture data points.
  • Display units include DP temperature, ppmv, ppmw, % RH, and others.
  • Calibration ranges from 50 to -112°F with accuracy of ±3.6°F above -148°F.
  • Operating pressure from 5 μ of Hg to 5000 psig.
  • Rechargeable battery with 15 to 24 hours of life.
  • Operating temperature range from 14 to 122°F.
Accessories:
  • Included: Carrying case, moisture probe with cable, sample system, battery, and charger.
  • Optional: Stainless steel braided hose, PC infrared adapter.
Compliance and Safety: Intrinsic-safety certification by Baseefa and CSA, compliant with EMC Directive 2004/108/EC.
Additional Options: Optional thermistor and pressure sensor available for specific probe series, with various pressure ranges and accuracy specifications.
See more

Catalog excerpts

PM880-1

Panametrics portable hygrometer The PM880 hygrometer is a complete, intrinsically safe, portable system with options and accessories to meet all industrial moisture measurement needs. This hygrometer is small, lightweight, and easy-to-use. The large LCD displays moisture readings in dew point (°C or °F), ppmv, ppmw, lb/MMSCF (natural gas) and a variety of other unit options. Data can be viewed in alphanumeric or graphic formats. A rechargeable battery pack and battery charger make this the ideal go-anywhere moisture analyzer. PANA037DS Rev. 4

 Open the catalog to page 1
PM880-2

• Hand-held portable design • Intrinsically safe • Large graphic display • Internal data logger • IrDA® communication with PC (Optional) • Stores up to 60 log/site files • Simple programming via graphic user interface • Compatible with all Panametrics moisture probes • Lightweight hand-held sample system • Convenient carrying bag to store hygrometer and all accessories The PM880 comes in a soft carrying case with zippered compartments, a handle and a shoulder strap. The case accommodates the PM880, a sample system, flexible hosing, probes with protective covers, a Moisture Image Series probe...

 Open the catalog to page 2
PM880-3

Overall Operational Channels Single channel • Weight, sample system: 4 lb (1.8 kg) Electronics Site parameter Menu-driven, graphic, operator interface programming uses keypad and soft-function keys. Online help functions. Memory storage for saving site parameters. Data logging Memory capacity to log over 100,000 moisture data points. Programmable keypad for log units, update times, and start/stop times. Display functions Displays measurements and logged data in alphanumeric or graphic format. Internal battery Battery life Battery charger Rechargeable. PM880 batteries can be installed or removed...

 Open the catalog to page 3
PM880-4

Temperature measurement Optional thermistor available for all Panametrics moisture probes Range Pressure measurement Optional pressure sensor available for TF Series and Moisture Image Series moisture probes Ranges Proof pressure Three times span of available range up to maximum 7500 psig (518 bar) 30 to 300 psig (3 to 21 bar) 50 to 500 psig (4 to 35 bar) 100 to 1000 psig (7 to 69 bar) 300 to 3000 psig (21 to 207 bar) 500 to 5000 psig (35 to 345 bar) Sample system The SS880A standard sample system comprises an inlet needle valve, a built-in coalescing filter and sample cell with a bypass needle...

 Open the catalog to page 4

All Panametrics catalogs and technical brochures

  1. PanaFlow FLI

    7  Pages

  2. XMO2pro

    6  Pages

  3. XMTCpro

    5  Pages

  4. HygroPro XP

    5  Pages

  5. HygroProII

    5  Pages

  6. MIS 2 Probe

    3  Pages

  7. M Series

    3  Pages

  8. moisture.IQ

    4  Pages

  9. OptiSonde™

    11  Pages

  10. Optica™

    15  Pages

  11. oxy.IQ

    6  Pages

  12. dew.IQ

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.