Panametrics Oxygen Transmitter The oxy.IQ is a highly reliable and cost-effective two-wire, loop-powered transmitter with a linearized 4 to 20 mA output. It measures oxygen in ten ppm ranges and six percentage ranges. All ranges are user-selectable. This compact transmitter uses proven sensor technology to accurately measure O2 in a variety of gases, even in hazardous environments.
Open the catalog to page 1oxy.IQ Datasheet I PANAMETRICS The oxy.IQ's oxygen sensor is an advanced galvanic fuel cell that provides superior performance, accuracy, stability and long life. The cell's innovative design eliminates the potential for negative signal output, reduces sources of contamination. The cell is unaffected by other background gases or hydrocarbons and is compatible with acid gases(OX-2 and OX-4 cells). Recovery from air at low ppm levels takes just a few minutes. Because the cell is self-contained, minimal maintenance is required. There is no electrolyte to change or electrodes to clean. When equipped...
Open the catalog to page 2oxy.IQ Datasheet I PANAMETRICS Process wetted materials Intrinsically safe installations require a zener barrier, one IS cable and one non-IS cable. Cable PN 704-1318: blue jacket, twisted pair with Output Total load must equal 250 O ±5% when using zener barrier Standard option package or IS package, no Zener barrier or galvanic isolator is required. Standard option mounted in Flameproof enclosure for ATEX or IECEX locations. Cable PN 704-1317: black jacket, twisted pair with SS process unit: 316 stainless steel, Viton® O-ring, gold plated sensor electrical contacts and glass (Chemraz O-Ring...
Open the catalog to page 3oxy.IQ Datasheet Note: all dimensions are inches [mm] FLAMEPROOF VERSION (ATEX/IECEX ONLY) 275 APPROX 160 140 oxy.IQ 135.00 63.5 Note: Flameproof version dimensions are shown as mm only
Open the catalog to page 4oxy.IQ Datasheet I PANAMETRICS Hazardous Location Non-Hazardous Location ZBB BUS BAR POWER SUPPLY oxy.IQ Transmitter Non-IS Cable INPUT DEVICE L Equipment connected to barrier inputs must not use or generate more than Z Total load ot R1 + R2 must equal 250 ohms Hazardous Location Non-Hazardous Location Class 1 Div 2 Enclosure (Black Jacket) INPUT DEVICE Maximum load of analog input device is dependent on power supply voltage and cable resistance. 1. For Class 1 Div 2 installation, the oxy.IQ shall be installed in an appropriately rated final enclosure accepting a Division 2 wiring method per...
Open the catalog to page 5oxy.IQ Datasheet Installation options Record selected option in blank spaces indicated at bottom of form. OXY.IQ-BCD-E Option Code " oxy.IQ Oxygen Transmitter; 4 to 20 mA output 3 Standard percent sensor 4 Acid percent sensor 3 Intrinsically safe for ATEX/IECEX and US/CAN Class 1 Div1 or Non-incendive for US/CAN Class 1 Div 2 4 EX&IP66 ATEX/lECEx 6mm fittings in aluminium enclosure 5 EX&IP66 ATEX/IECEx 1/4" fittings in aluminium enclosure 6 EX&IP66 ATEX/lECEx 6mm fittings in 316SS enclosure F-Base adapter 2 Special consult factory Note : For Option C=3 intrinsic safety, either zener barrier or...