OptiSonde™

OptiSonde™
1 / 11 PagesView full catalog

OptiSonde™

Product catalog summary
Overview: The OptiSonde™ chilled mirror hygrometer is a precision instrument designed for accurate humidity measurement in various applications, including metrology labs and industrial settings. It provides NIST traceable humidity transfer standards, known for its accuracy and stability.
Key Features:
  • Durable, compact design for easy installation.
  • Built-in data logger records data for 100 days at a 1-second sample rate.
  • Displays and transmits parameters like dew point, relative humidity, and absolute humidity.
  • Digital RS-232 interface for data transfer to PCs using PanaView™ software.
  • PACER® cycle for automatic mirror cleaning to maintain accuracy.
Applications:
  • Environmental test chambers
  • Engine test cells
  • Clean rooms
  • Air conditioning and heat exchange coil testing
  • Metrology labs
Theory of Operation: Utilizes a chilled mirror to measure dew or frost point temperature by balancing condensation and evaporation rates. Temperature is measured using a precision four-wire platinum RTD.
Technical Specifications:
  • Power: 100-240 VAC or 18-32 VDC
  • Enclosure: Cast aluminum for wall mount, aluminum body with plastic front bezel for bench top
  • Dew point accuracy: ±0.2°C
  • Temperature accuracy: ±0.15°C
  • Operating temperature: -10°C to 60°C
  • Data logger: Records eight parameters for a minimum of 100 days
Contamination Control: The PACER® cycle cleans the mirror by evaporating contaminants. Manual cleaning is possible with a cleaning solution.
Calibration Services: Calibration is crucial for maintaining measurement integrity. Panametrics offers on-site and mail-in calibration services to ensure accuracy and reliability.
Sensor Specifications: Detailed specifications for different sensor models, including single-stage and two-stage chilled mirrors, highlighting their accuracy, operating conditions, and construction materials.
Specifications:
  • Temperature Control: Thermostatically controlled with set points at 25°C, 40°C, 55°C, 70°C, 85°C, and 100°C.
  • Pressure: Maximum of 50 psig (4.5 bar).
  • Power: 100/115/230 VAC, 50/60 Hz, 75 watts.
  • Sensor Body: Made of cast aluminum with a 314 stainless steel flow cell.
  • Sensor Wetted Material: Includes 302, 316 stainless steel, silicone o-ring, BK-7 glass, rhodium or platinum mirror.
  • Mirror: Standard rhodium plated copper, optional solid platinum.
  • Vapor Barrier: Mylar, upgradeable to stainless steel.
  • Electrical Connector: MS-style multipin connector with IEC receptacle for AC power.
  • Weight: 7 lb (3.2 kg) net.
1311-DR Four-Stage Chilled Mirror Specifications:
  • Sensing Element: Four-wire 1/3 Class A DIN 43760 PRT, 100 W @ 32°F (0°C).
  • Dew/Frost Point Accuracy: ±0.2°C with sensitivity >0.03°C and repeatability ±0.05°C.
  • Cooling Stages: Four-stage TEC module with auxiliary liquid cooling.
  • Depression: Air cooled at 95°C and liquid cooled at 105°C with 15°C cooling water.
  • Measurement Range: -65°C to 25°C dew/frost point in air, -75°C to 15°C in liquid-cooled mode.
  • Sample Flow: 0.5 to 5.0 SCFH (0.25 to 2.5 L/min).
  • Operating Temperature: 0°C to 35°C.
  • Pressure: Maximum 300 psig (22 bar).
  • Power: 100/115/230 VAC, 50/60 Hz, 300 watts.
  • Weight: 34 lb (16 kg) net.
T-100 Four-Wire PRTD Temperature Sensor:
  • Sensing Element: Four-wire 1/3 Class A DIN 43760 PRT, 100W @ 0°C.
  • Accuracy: 0.15ºC.
  • Range: -100ºC to 100ºC.
  • Response Time: 7 seconds for 25ºC to 70ºC step change in fluid.
  • Sensor Body Material: Stainless steel.
  • Cable: PTFE insulation rated to 150ºC, 3 m (10 ft) length.
  • Weight: 0.9 kg (2 lb).
Accessories:
  • Hard shell carrying case for benchtop unit with accessories.
  • Calibration-multi-year.
  • Extended warranty.
  • Polytetrafluoroethylene cable 150°C, 10 ft (3 m) standard length.
Ordering Information:
  • Analyzer: Options for benchtop or wall mount.
  • Power: Options for 100-240 VAC, 50-60 Hz or 18-32 VDC.
  • Chilled Mirror Sensor: Various models including single and multi-stage sensors.
  • Chilled Mirror Type: Rhodium or Platinum.
  • Vapor Barrier: Mylar or Stainless steel.
  • Analyzer to Sensor Cable: Options from 10 ft to 300 ft.
  • Temperature Sensor: Options for T-100 with various cable lengths.
Notes:
  • 1111H sensors are only available with mylar vapor barriers.
  • D2 sensors are only available with stainless steel vapor barriers.
  • Analyzer to sensor cable depends on the analyzer and sensor ordered.
  • All systems have standard dew point accuracy ±0.2°C Td and temperature ±0.15°C Ta.
  • Specific configurations required for wall mount options.
See more

Catalog excerpts

OptiSonde™-1

Chilled mirror hygrometer Chilled mirror hygrometers are used in standards and metrology labs as well as in industrial applications where precise and repeatable humidity measurement and control are required. The inherent accuracy and long term stability provide many advantages over other types of humidity measurement technologies.

 Open the catalog to page 1
OptiSonde™-2

OptiSonde™ Datasheet I PANAMETRICS The OptiSonde chilled mirror hygrometer is a National Institute of Standards and Technology (NIST) traceable humidity transfer standard at an exceptional value. The compact rugged analyzer is connected to either a single-or two-stage chilled mirror sensor and PRTD. Chilled mirrors are the humidity sensors of choice when laboratory and process measurements require high precision without long-term drift. An LCD indicates two simultaneous user-configured parameters. OptiSonde provides two user-configured analog (4 to 20 mA) outputs. The display and front panel...

 Open the catalog to page 2
OptiSonde™-3

OptiSonde™ Datasheet Chilled mirrors require a nominal flow rate across the mirror to achieve the optimal dew/frost formation and response time. The sensor should either be installed in a duct with moving air or be equipped with a sampling pump. The optimum flow rate is 0.5 to 2.5 SCFH (0.25 to 1.2 L/min). Panametrics provides sampling systems to condition the temperature, regulate the pressure and filter process air before reaching the chilled mirror. Our applications engineers would be pleased to discuss your application in detail and provide a recommendation for the system best suited to your...

 Open the catalog to page 3
OptiSonde™-4

OptiSonde™ Datasheet OptiSonde specifications Power • 100 - 240 VAC, 50 to 60 Hz, 60 watts • 18-32 VDC (bench top only) Enclosure material • Wall mount: Cast aluminum • Bench top: Aluminum body with plastic front bezel • Wall mount: 26.6 x 20.8 x 11.4 cm (h x w x d) • Bench top: 9.4 x 20.3 x 22.4 cm (h x w x d) • Wall mount: 2.4 kg • Bench mount: 1.4 kg Ingress • Wall mount: IP-65 protection rating • Bench top: IP-20 Front panel keys Rubber function keys—may be locked out via software Dependent on sensor used Temperature accuracy Other humidity parameters The range and accuracy of absolute humidity...

 Open the catalog to page 4
OptiSonde™-5

OptiSonde™ Datasheet 1111H single stage chilled mirror specifications Dew/frost point accuracy Typical dew point measurement range -15ºC to 25ºC Td at 25ºC, 1 atmosphere for standard air.(Equivalent to 6-100% RH) Sample flow rate Operating temperature Operating pressure Derived from analyzer Sensor body Epoxy-coated aluminum PTFE filter optional (standard on 1111H) Rhodium-plated copper (solid platinum optional) Vapor barrier Sensor wetted material Epoxy-coated aluminum, rhodium copper, mylar Electrical connector MS style multipin keyed connector • MB-11: Wall mounting bracket (1111H) • PTFE:...

 Open the catalog to page 5
OptiSonde™-6

OptiSonde™ Datasheet D2 two-stage chilled mirror specifications Sensing element Dew/frost point ± 0.2ºC accuracy 65ºC at 25ºC, 1 atmosphere for standard air Typical dew point measurement range -35ºC to 25ºC Td at 25ºC, 1 atmosphere for standard air.(Equivalent to 1 to 100 % RH) Sample flow rate Operating temperature Operating pressure Derived from analyzer View port Equipped with illuminated view port that enables observation of mirror Sensor body Cast aluminum with 314 SS flow cell Rhodium-plated copper (solid platinum optional) Vapor barrier Stainless steel Sensor wetted material 302, 314,...

 Open the catalog to page 6
OptiSonde™-7

OptiSonde™ Datasheet 1211H two stage chilled mirror specifications Sensing element Dew/frost point ± 0.2ºC accuracy -35ºC to 25ºC Td at 25ºC, 1 atmosphere for standard air. (Equivalent to 6 to 100% RH) Sample flow rate Operating temperature Operating pressure Derived from analyzer Sensor body Cast aluminum with 314 SS flow cell Rhodium-plated copper (solid platinum optional) Vapor barrier Sensor wetted material 302, 314, 316 stainless steel, silicone O-ring, rhodium plated copper or platinum mirror Electrical connector MS style multipin keyed connector Platinum mirror Stainless steel vapor barrier...

 Open the catalog to page 7
OptiSonde™-8

OptiSonde™ Datasheet I PANAMETRICS Sensing Four-wire 1/3 Class A DIN 43760 PRT, 100 W Dew/frost point Standard: ±0.2°C Hysteresis Negligible Cooling stages Two-stage TEC module Depression 85°C at 75°C body temperature and atmospheric pressure Electrical MS-style multipin connector connector IEC receptacle for AC power -10°C to 75°C dew/frost point (Td) in air @ 75°C body temperature in 25°C ambient temperature and atmospheric pressure. Equivalent to 0.7% to 100% RH. Other parameters based on calculations. Sample flow 0.5 to 5.0 SCFH (0.25 to 2.5 L/min) Heater control Thermostatically controlled....

 Open the catalog to page 8
OptiSonde™-9

OptiSonde™ Datasheet I PANAMETRICS Sensing Four-wire 1/3 Class A DIN 43760 PRT, 100 W Dew/frost point Standard: ±0.2°C Hysteresis Negligible Cooling stages Four-stage TEC module Auxiliary Liquid cooling jacket Depression, air 95°C at 25°C and atmospheric pressure Inlet/outlet 1/4 in (6 mm) OD tubing compression fittings Electrical MS-style multipin connector mates connector IEC receptacle for AC power S Stainless steel vapor barrier Depression, 105°C with 15°C cooling water liquid cooled Typical • -65°C to 25°C dew/frost point (Td) in air measurement @ 25°C and atmospheric pressure. range • -75°C...

 Open the catalog to page 9
OptiSonde™-10

OptiSonde™ Datasheet I PANAMETRICS Sensing Four-wire 1/3 Class A DIN 43760 PRT, Response time 7 seconds for 25°C to 70°C step change in fluid Sensor body Stainless steel Cable PTFE insulation rated to 150°C, 3 m (10 ft) length, spring strain relief Power Low voltage derived from analyzer PTFE: FILTER for 1111H Sensor • Hard shell carrying case for benchtop unit with accessories. • Extended warranty

 Open the catalog to page 10
OptiSonde™-11

Ordering information Analyzer 1 Benchtop 2 Wall mount Power 1 100-240 VAC, 50-60 Hz 2 18-32 VDC Chilled mirror sensor 0 None 1 1111H single stage sensor, 1” M-NPT fitting 2 1111H single stage sensor. Flange for duct mounting and PTFE filter 3 D2 two stage sensor 4 1211H two stage high temperature and pressure sensor 5 SIM-12H two stage heated sensor. 115 VAC 6 SIM-12H two stage heated sensor. 230 VAC 7 HSS-12H two stage heated sensor and sampling system. 115 VAC 8 HSS-12H two stage heated sensor and sampling system. 230 VAC 9 1311-DR four stage chilled mirror sensor. 100 VAC A 1311-DR four stage...

 Open the catalog to page 11

All Panametrics catalogs and technical brochures

  1. PanaFlow FLI

    7  Pages

  2. XMO2pro

    6  Pages

  3. XMTCpro

    5  Pages

  4. HygroPro XP

    5  Pages

  5. HygroProII

    5  Pages

  6. PM880

    4  Pages

  7. MIS 2 Probe

    3  Pages

  8. M Series

    3  Pages

  9. moisture.IQ

    4  Pages

  10. Optica™

    15  Pages

  11. oxy.IQ

    6  Pages

  12. dew.IQ

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.