1. Catalogs
  2. Panametrics
  3. DigitalFlow™ GS868

DigitalFlow™ GS868

DigitalFlow™ GS868

DigitalFlow™ GS868

Product catalog summary
Overview: The DigitalFlow™ GS868 is an ultrasonic steam mass flowmeter designed for measuring the mass flow rate of saturated or superheated steam. It offers no pressure drop, wide rangeability, ease of installation, low maintenance, and high accuracy.
Specifications: The flowmeter uses the correlation Transit-Time™ technique with compact ultrasonic transducers installed in the pipe. It measures the difference in upstream and downstream transit times to calculate velocity and volumetric flow rate. Mass flow is calculated using temperature and pressure inputs and built-in steam tables. It supports pipe sizes from 2 in to 48 in (50 mm to 1200 mm) and velocities from 0.1 to 150 ft/s (0.03 to 46 m/s).
Features: Key features include bidirectional flow measurement, no moving parts, no pressure drop, wide rangeability with a 1500:1 turndown ratio, non-obstructive flow measurement, tolerance to dirty streams, low maintenance, and suitability for high temperatures. A two-path measurement option is available for maximum accuracy.
Applications: The flowmeter is suitable for various industries, including HVAC, pneumatic power systems, food and beverage, water purification, chemical and petrochemical, electric power generation, steel industry, public works, and manufacturing.
Installation and Operation: The system consists of transducers, preamplifiers, and an electronics console, which can be installed as part of a flowcell or directly into the pipeline. The console can be located up to 500 ft (150 m) from the transducers. It offers local and remote programming and output options.
Outputs and Interfaces: The flowmeter provides digital and analog output options, including RS232, RS485, Modbus, Ethernet, and Foundation fieldbus. It features a menu-driven operator interface and data logging capabilities for over 43,000 flow data points.
Technical Specifications: The flowmeter operates within a temperature range of –4°F to 131°F (–20°C to 55°C) and a pressure range of 0 to 2700 psig (1 to 187 bar), with optional higher pressure capabilities. It complies with European EMC and PED directives.
Additional Options: The PanaView PC-interface software allows communication with a PC for site management and data logging. The flowmeter demonstrates minimal permanent pressure loss compared to other flowmeter types.
See more

Catalog excerpts

DigitalFlow™ GS868-1

DigitalFlow™ GS868 Ultrasonic steam mass flowmeter The DigitalFlow GS868 steam ultrasonic flowmeter is designed to measure the mass flow rate of saturated or superheated steam. It offers a unique combination of no pressure drop, wide rangeability, ease of installation, low maintenance and high accuracy in a full-feature flowmeter package.

 Open the catalog to page 1
DigitalFlow™ GS868-2

DigitalFlow™ GS868 Datasheet I PANAMETRICS • Wide rangeability with 1500 to 1 turndown ratio • Non-obstructive flow measurement • Tolerance to dirty streams • Suitable for high temperatures • Two-path measurement available for maximum accuracy The DigitalFlow GS868 steam ultrasonic flowmeter is a complete ultrasonic flow metering system that measures saturated or superheated steam for: • Heating, ventilating and air conditioning (HVAC) • Pneumatic power systems • Food and beverage industry • Water purification and distillation • Chemical and petrochemical industries • Electric power generation...

 Open the catalog to page 2
DigitalFlow™ GS868-3

With its broad range of measurement velocities and its ability to measure flow in any pipe from small to very large, one DigitalFlow GS868 meter does the job of several conventional meters. It handles pipes from 2 in to 48 in (50 mm to 1200 mm) in diameter and velocities from 0.1 to 150 ft/s (0.03 to 46 m/s)—in either direction—in saturated or superheated steam. For maximum accuracy, use a two-channel meter to measure along two different paths at the same location. A two-channel meter can also measure the flow in two separate pipes for additional cost savings. Straightforward installation is...

 Open the catalog to page 3
DigitalFlow™ GS868-4

DigitalFlow™ GS868 Datasheet I PANAMETRICS ElectronicsFlow measurement Patented Correlation Transit-Time mode • Standard: Epoxy-coated aluminum weatherproof Type 4X/IP66, FM/CSA Class I, Division 2, Groups A,B,C&D • Optional: Stainless steel, fiberglass, explosion-proof, flameproof, ISSep 03ATEX113 Standard: Weight 11 lb (5 kg), size (h x w x d) 14.24 in x 11.4 in x 5.12 in (362 mm x 290 mm x 130 mm) Digital interfaces Standard: RS232 Optional: RS485 (multiuser) Optional: Modbus® RS485 or TCP protocol Optional: Ethernet Optional: OPC server Optional: Foundation fieldbus Site parameter Menu-driven...

 Open the catalog to page 4
DigitalFlow™ GS868-5

The DigitalFlow GS868 communicates with a PC through a serial interface and Windows® operating systems. Consult the manual for details on sites, logs and other operations with a PC. Permanent pressure loss by flowmeter type Saturated steam flow 100 ft/s, 4 in Sch 40, 40 psig (2.7 bar) Saturated steam flow 100 ft/s, 12 in Sch 160, 300°F (148°C) Join the conversation and follow us on LinkedIn Copyright 2023 by Panametrics LLC. All rights reserved. PANA017DS_R3 (04/2023)

 Open the catalog to page 5

All Panametrics catalogs and technical brochures

  1. PanaFlow FLI

    7  Pages

  2. XMO2pro

    6  Pages

  3. XMTCpro

    5  Pages

  4. HygroPro XP

    5  Pages

  5. HygroProII

    5  Pages

  6. PM880

    4  Pages

  7. MIS 2 Probe

    3  Pages

  8. M Series

    3  Pages

  9. moisture.IQ

    4  Pages

  10. OptiSonde™

    11  Pages

  11. Optica™

    15  Pages

  12. oxy.IQ

    6  Pages

  13. dew.IQ

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.