video corpo

PanaFlow LC
8Pages

{{requestButtons}}

Catalog excerpts

PanaFlow LC - 1

Panametrics ultrasonic clamp-on liquid flow meter for process applications Introducing the PanaFlow LC The PanaFlow LC is the latest generation in permanent clamp-on ultrasonic flow meters for process applications from Panametrics’ line of ultrasonic meters. It capitalizes on the superior performance of its predecessor, the Digital Flow XMT868, but includes improved signal processing and performance. • Suitable for hazardous area environment with either an explosionproof or flameproof design for vital process environments PanaFlow LC advantages • Wide selection of transducers suitable for many applications • Hazardous area certification • Improved accuracy and repeatability through enhanced signal processing • HART and Foundation Fieldbus digital protocols • Wider flow range to handle more diverse flow measurements • Velocity, volumetric, mass, and totalizer flow rate measurements • Based on legacy Panametrics technology for reliable flow measurements. • Designed for most refinery or chemical liquids including hydrocarbon liquids, crude oil, lubricating oils, refined hydrocarbon oils, solvents, chemicals, water, sea water, and more • Suitable for most pipe sizes and materials, both lined or unlined • Optional SIL certified configuration for safety

Open the catalog to page 1
PanaFlow LC - 2

Panametrics clamp-on flow ultrasonic With transit time flow measurement, two transducers serve as both ultrasonic signal generators and receivers. When mounted on a pipe, they are in acoustic communication with each other, meaning the second transducer can receive ultrasonic signals transmitted by the first transducer and vice versa. In operation, each transducer functions as a transmitter, generating a certain number of acoustic pulses, and then as a receiver for an identical number of pulses. The transit time interval between the transmission and reception of the signal is measured in...

Open the catalog to page 2
PanaFlow LC - 3

PanaFlow LC specifications Operation and performance Fluid types Liquids: acoustically conductive fluids, including most clean liquids, and many liquids with small amounts of entrained solids or gas bubbles. Flow measurement Patented Correlation Transit-TimeTM model Pipe sizes Hazardous area rating US/CAN: Class I, Division 1, Groups B, C, D; Class I, Zone 1, Ex d IIC T6; ATEX/IECEx: Ex d IIC T6 FISCO outputs Ta = -40° C to +60° C, Type 4X More certifications available upon request Temperature range • Operating: -40° F to 149° F (-40° C to +65° C)* • Storage: –67° F to 167° F (–55° C to 75°...

Open the catalog to page 3
PanaFlow LC - 4

Clamp-on ultrasonic flow transducers Clamping fixtures Strap Clamping Fixture (SCF) Frequency: 0.5, 1, or 2MHz Materials: Stainless steel and plastic Rating: IP66 with junction box Temperature (process): -40° C to 150° C (-40o F to 302o F) Hazardous Area: US/CAN: Class I, Division 1, Groups B, C, D ATEX: Ex md IIC T6 IECEx: Ex md IIC T6 Gb Stainless steel transducer yoke Stainless steel strapping Alignment bar for proper alignment Note: CFG fixture used for small pipe C-RS transducer installation. Contact Panametrics for additional certifications. C-PT transducer Frequency: 0.5, 1, or 2 MHz...

Open the catalog to page 4
PanaFlow LC - 5

Ordering information for PanaFlow LC system 1. Order XMT1000 transmitter Model type Measurment paths Conformal coating 0 conformal coating No 1 Conformal coating Powder coated aluminum enclosure SS stainless steel enclosure 316 Input/output 00 No additional input/outputs 01 Additional two AO, two AI 02 Additional two AO, two AI, one RTD (PT100-3 wire) 03 Additional two AO, two AI, one RTD (PT100-4 wire) 04 Additional two AO, two AI, one RTD (PT1000-3 wire) 05 Additional two AO, two AI, one RTD (PT1000-4 wire) 06 Additional two AO, two RTD (PT100-3 wire) 07 Additional two AO, two RTD...

Open the catalog to page 5
PanaFlow LC - 6

2. Order transducer and fixture system Model type XMTXP Transducer and fixture system R05 0.5MHz C-RS with SCF fixture R10 1MHz C-RS with SCF fixture R20 2MHz C-RS with SCF fixture P05 0.5MHz C-PT with SCF fixture P10 1MHz C-PT with SCF fixture P20 2MHz C-PT with SCF fixture R20S 2MHz C-RS with CFG fixture Certification and junction box type 00 junction box No AX US/CAN aluminum junction box EX ATEX/IECEx aluminum junction box UXSS US/CAN/ATEX/IECEx stainless steel junction box Pipe outer diameter <> Value of pipe outer diameter Pipe unit of measurement IN Pipe size - inches MM size -...

Open the catalog to page 6
PanaFlow LC - 7

3. Order flowmeter cable Model type FC Model number Cable type HAZCOAX Transducer cable for conduit ARARCTCOAX Arctic SWA armored cable Cable units FT Feet connection Front Front thread 0 No cable gland 075HAZLOC 3/4in cable gland M20HAZLOC cable gland M20 075HAZLOCBG cable gland 3/4in M20HAZLOCBG M20 cable gland End connection BNC75 BNC for standard transducers BNC33JC BNC (ARFIRECOAX) for standard transducers End thread 0 No cable gland 075HAZLOC Nickel plated Special 0 None S Special FC - ARFIRECOAX (Example part number)

Open the catalog to page 7
PanaFlow LC - 8

Item Description PanaFlow LC three path kit (aluminum enclosure with ATEX/IECEx certification) PanaFlow LC three path kit (stainless steel enclosure with ATEX/IECEx certification) PanaFlow LC three path kit (aluminum enclosure with US/CAN certification) PanaFlow LC three path kit (stainless steel enclosure with US/CAN certification) XMT-132M4308 Wireless HART kit for the XMT1000 transmitter Panametrics, a Baker Hughes Business, provides solutions in the toughest applications and environments for moisture, oxygen, liquid and gas flow measurement. Experts in flare management, Panametrics...

Open the catalog to page 8