Group: Baker Hughes
Catalog excerpts
Panametrics Gas Flow Ultrasonic Transmitter Features • Economical flow measurement in a compact transmitter The DigitalFlow XGM868 gas flow transmitter is a complete ultrasonic flow metering system for measurement of most gases including: • No moving parts • No pressure drop • Wide rangeability with 150 to 1 turndown ratio • Non-obstructive flow measurement • Tolerance to dirty streams • Low maintenance • Suitable for high temperatures • Two-path measurement available for maximum accuracy • Hydrocarbon gases • Vent gases • Biogases • Digester gases • Fuel gases • Waste gases • Incinerator air flow • Vapor recov
Open the catalog to page 1The DigitalFlow XGM868 gas ultrasonic flow transmitter is designed to measure the flow rate of virtually any gas. The DigitalFlow XGM868 flow transmitter offers a unique combination of rangeability, ease of installation, low maintenance and accuracy in a low-cost transmitter. The state-of-the-art XGM868 shares the many advantages offered by the other products in the Panametrics line of innovative ultrasonic flowmeters. The all-digital XGM868 creates no pressure drop; has no moving parts or parts that foul or collect debris; seldom requires maintenance; and provides reliable, drift-free...
Open the catalog to page 2Specifications Operation and performance Fluid Types Acoustically conductive gases Pipe Sizes 2 to 120 in. NB (50 to 3,000 mm) and larger Pipe Materials All metals. Consult Panametrics for other materials. Flow Accuracy (Velocity) ±1% to 2% of reading typical Accuracy depends on pipe size and whether measurement is one-path or two-path. Accuracy to ±0.5% of reading may be achievable with process calibration. Repeatability ±0.2% to 0.5% of reading Range (Bidirectional) –150 ft/s to 150 ft/s (–46 m/s to 46 m/s) Rangeability (Overall) 150:1 Specifications assume a fully developed flow profile...
Open the catalog to page 3Transducer cables Digital Interfaces • Standard: RS232 • Optional: RS485 (multiuser) • Standard: One pair of coaxial cables, type RG62 AU, or as specified for transducer type • Optional Hart® protocol • Optional: Lengths up to 1000 ft (330 m) maximum • Optional: Modbus® protocol High temperature and high pressure Ultrasonic Flow Transducers Data Logging • Standard: None • Optional: Memory capacity (linear and/or circular type) to log over 150,000 flow data points Bundle Waveguide Technology™ (BWT) System transducer and holder (see BWT System specifications) are available. European...
Open the catalog to page 4All Panametrics catalogs and technical brochures
-
Flow Product Guide
44 Pages
-
PanaFlow LC
8 Pages
-
TransPort® PT900 Datasheet
8 Pages
-
TransPort® PT878GC Datasheet
8 Pages
-
AquaTrans™ AT600 Datasheet
5 Pages
-
DigitalFlow™ GC868 Datasheet
7 Pages
-
DigitalFlow™ DF868 Datasheet
6 Pages
-
PanaFlow™ XMT1000 Datasheet
4 Pages
-
DigitalFlow™ GF868 Datasheet
7 Pages
-
PanaFlow Z3 Datasheet
7 Pages
-
DigitalFlow™ GM868 Datasheet
5 Pages
-
DigitalFlow™ GS868 Datasheet
4 Pages
-
PanaFlow HT Datasheet
8 Pages
-
PanaFlow LZ System Datasheet
5 Pages
-
Panametrics Service Catalog
2 Pages