Catalog excerpts
AC Output Spcifications OUTPUT FREQUENCY 15to 1.200 Hz. Full Power. LOAD REGULATION 0.25% 15 to 400 Hz. Improves to less than 0.1 % with extemal sens and CSC enabled. OUTPUT DISTORTION 0.25%THDAVG 15 to 200 Hz. 0.50% THDavG 200 to 1,200 Hz. RESPONSETIME 60 us驩e typical, 10-90% load step. Measurements VOLTAGE (True RMS) Range 0-354 VACln Resolution 0.1 VAC to front panel. 0.001 VAC to remote interface. Accuracy ±0.2% of range +cal.ref. CURRENT (True RMS) Range 30Arms Resolution 0.01 A to front panel. 0.001 A to remote interface. Accuracy ±0.2% of range +cal.ref. POWER Measures True Power...