SC-200
10Pages

{{requestButtons}}

Catalog excerpts

SC-200 - 1

Applications • Drinking Water • Wastewater • Industrial Water • Power One Controller for the Broadest Range of Sensors. Choose from 30 digital and analog sensor families for up to 17 different parameters. Maximum Versatility The sc200 controller allows the use of digital and analog sensors, either alone or in combination, to provide compatibility with Hach's broad range of sensors, eliminating the need for dedicated, parameter-specic controllers. Ease of Use and Condence in Results Large, high-resolution, transreective display provides optimal viewing resolution in any lighting condition. Guided calibration procedures in 19 languages minimize complexity and reduce operator error. Password-protected SD card reader offers a simple solution for data download and transfer. Visual warning system provides critical alerts. Wide Variety of Communication Options Utilize two to ve analog outputs to transmit primary and secondary values for each sensor, or integrate Hach sensors and analyzers into MODBUS RS232/RS485, Probus® DP, and HART networks. Password protected SD card reader offers a simple solution for data download and transfer, and sc200 and digital sensor conguration le duplication and backup.

Open the catalog to page 1
SC-200 - 2

Controller Comparison Previous Models sc100™ Controller GLI53 Controller • Improved user interface— 50% bigger • Easier to read in daylight and sunlight Data Management irDA Port/PDA Service Cable SD Card Service Cable • Simplifies data transfer • Standardized accessories/ max compatibility Sensor Inputs 2 Max Direct Digital Analog via External Gateway 2 Max Analog Depending on Parameter 2 Max Digital and/or Analog with Sensor Card • Simplifies analog sensor connections • Works with analog and digital sensors Analog Inputs 1 Analog Input Signal Analog 4-20mA Card • Enables non-sc analyzer...

Open the catalog to page 2
SC-200 - 3

Choose from Hach's Broad Range of Digital and Analog Sensors Parameter AMTAX™ sc, NH4D sc, AISE sc, AN-ISE sc Chlorine Dioxide Dissolved Oxygen Dissolved Oxygen NITRATAX™ sc, NO3D sc, NISE sc, AN-ISE sc Sludge Level Suspended Solids Ultra Pure Conductivity Ultra Pure pH/ORP Connect up to two of any of the sensors listed above, in any combination, to meet your application needs. The diagrams below demonstrate the potential configurations. Operation of analog sensors requires the controller to be equipped with the appropriate sensor module. Contact Hach Technical Support for help with...

Open the catalog to page 3
SC-200 - 4

Graphic dot matrix LCD with LED backlighting, transreective Display Size Display Resolution Power Requirements (Voltage) Operating Temperature Range Analog Outputs Two (Five with optional expansion module) to isolated current outputs, max 550 Ω , Accuracy: ± 0.1% of FS (20mA) at 25 °C, ± 0.5% of FS over -20 °C to 60 °C range Analog Output Functional Mode Linear, Logarithmic, Bi-linear, PID Security Levels Mounting Congurations Wall, pole, and panel mounting Enclosure Rating Conduit Openings Relay: Operational Mode Primary or secondary measurement, calculated value (dual channel only) or...

Open the catalog to page 4
SC-200 - 5

Surface Mounting Dimensions Mounting Dimensions (Rear View) Bracket (supplied) for Surface Mounting (Not compatible with Weather and Sun Shield p/n 9220600 when surface mounting.) Panel Mounting Dimensions Recommended Cutout Minimum Spacing Dimensions Door Opening Details 3/4" to 2-1/2" Vertical / Horizontal Pipe

Open the catalog to page 5
SC-200 - 6

Ordering Information sc200 for Hach Digital and Analog Sensors LXV404.99.00552 sc200 controller, 2 channels, digital sc200 controller, 1 channel, digital sc200 controller, 1 channel, pH/DO sc200 controller, 1 channel, Conductivity sc200 controller, 2 channels, digital, Modbus RS232/RS485 sc200 controller, 2 channel, pH/DO Note: Other Sensor combinations are available. Please contact Hach Technical Support or your Hach representative. Note: Communication options (MODBUS, Probus DPV1, and HART) are available. Please contact Hach Technical Support or your Hach representative. sc200 controller,...

Open the catalog to page 6
SC-200 - 7

DATA SHEET 9185sc Amperometric Ozone Sensor Features and Benefits Few Interferences from Oxidants or pH over a Wide Measurement Range Bromine, chloramines, chlorine, chlorine dioxide, hydrogen peroxide, and pH do not interfere with ozone measurements using the Hach 9185sc Amperometric Ozone Sensor which can measure from 0 to 2 mg/L ozone. Ideal for Low-Conductivity Samples The 9185sc ozone system has a low minimum detection limit of 0.005 mg/L ozone. Because the amperometric cell is separated from the sample by the membrane and is immerged into an electrolytic medium, the 9185sc ozone...

Open the catalog to page 7
SC-200 - 8

Specifications* Measurement Range 0 to 2 ppm (mg/L) ozone (O3) Minimum Detection Limit 5 ppb or 0.005 mg/L O3 Measurement Technology Amperometric/Membrane (electrode, membrane, electrolyte) Dimensions 270 x 250 mm (10.63 x 9.84 in.) Shipping Weight 6.5 kg (14.3 lbs.) Accuracy 3% or ±10 ppb O3, whichever is greater Interferences No interference from bromine, chloramines, chlorine, chlorine dioxide, or hydrogen peroxide Zero Calibration Electrically or with ozone-free water Cleaning: can be set to inject acid through the measurement cell for cleaning purposes. Response Time 90% in less than...

Open the catalog to page 8
SC-200 - 9

Engineering Specifications 1. The sensor shall continuously measure ozone (03) 2. The measurement technology shall be amperometric/membrane which includes electrode, 3. The measuring range shall be from 0 to 2 ppm 03. 4. The minimum detection limit shall be 5 ppb or 5. The accuracy shall be less than 3% or ±10 ppb of the measured value, whichever is greater. 6. The response time shall be approximately 90 seconds. 7. The flow rate of sample shall be 200 to 250 mL7minute. 8. The calibration method for the analyzer shall be comparison with lab method. 9. The transmitter enclosure shall be...

Open the catalog to page 9
SC-200 - 10

Ordering Information LXV433.99.00001 9185sc Ozone Analyzer 9180sc Intermittent Flow Unit 57432-00 Instrument Stand 54488-00 125V Power Cord with Strain Relief 54489-00 230V Power Cord with Strain Relief At Hach, it’s about learning from our customers and providing the right answers. It’s more than ensuring the quality of water—it’s about ensuring the quality of life. When it comes to the things that touch our lives... Keep it pure. Make it simple. Be right. Digital Extension Cables Standard cable length is 0.4 m (1.25 ft.) 61224-00 1 m (3.2 ft.) 57960-00 7.6 m (25 ft.) 57961-00 15.2 m (50...

Open the catalog to page 10

All Ozone Engineers catalogs and technical brochures