Oxy Clean

Oxy Clean

Product catalog summary
Overview: The OxyGuard OxyClean is an attachment designed to maintain the cleanliness of OxyGuard dissolved oxygen probes in challenging environments. It utilizes compressed air to efficiently remove deposits from the probe membrane with minimal disturbance to measurements.
Specifications: The OxyClean is compatible with OxyGuard probes and requires a compressed air supply. It operates with a 5-second air blast at up to 2 bar pressure every 30 minutes.
Installation and Use: The attachment is easy to install by slipping it onto the probe and securing it with a grub screw. It connects to a compressed air supply controlled by a magnetic valve. For systems like OxyGuard Atlantic or Commander, a timer can control the valve. For Model 420 or 840, a magnetic valve with a built-in timer is recommended.
Special Features: A specialized cleaner is available for the Pioneer mounting system, integrated into the probe mount tip and functioning similarly to the OxyClean.
Ordering Information: The OxyClean attachment is available under the code D091, and the magnetic valve with timer is available under the code K10TMV. Connection instructions are provided with the valve.
Contact Information: OxyGuard International A/S, Farum Gydevej 64, DK-3520 Farum, Denmark. Tel: +45 4582 2094, Fax: +45 4582 1994, Email: [email protected], Website: www.oxyguard.dk
See more

Catalog excerpts

Oxy Clean-1

OxyGuard OxyClean Probe Cleaner Attachment that keeps OxyGuard Probes Clean in Difficult Environments The OxyGuard OxyClean is a small attachment with a large effect for use with OxyGuard dissolved oxygen probes! Compressed air is used, and a blast of air of a few seconds is enough to clean deposits from the membrane amazingly efficiently. This short blast of air is hardly enough to disturb the measurement, and blowers controlled by the oxygen measurement will not normally be affected. The OxyClean is very easy to use - slip it onto the probe so that it fits onto the top part, just above the join in the probe, then tighten the small grub screw to hold it in place. Connect it to a supply of compressed air controlled by a magnetic valve. A 5 second blast of compressed air at up to 2 bar pressure every 30 minutes should suffice for most uses. If you use an OxyGuard Atlantic (or a Commander system) you can let a timer in the unit control a standard magnetic valve. If, however, you use the cleaner with an OxyGuard Model 420 or Model 840 a magnetic valve with built-in timer should be used. A special type of compressed air cleaner is available for the Pioneer mounting system. This cleaner is incorporated into the probe mount tip of the Pioneer, and operates in the same manner as the OxyClean. Please see the Pioneer brochure for details. OxyClean attachment. Magnetic valve with timer. Please see the instructions enclosed with the valve for connection details. Data subject to change without notice OxyGuard International A/S, Farum Gydevej 64, DK-3520 Farum, Denmark Tel +45 4582 2094; Fax +45 4582 1994 [email protected]; www.oxyguard.dk

 Open the catalog to page 1

All OxyGuard catalogs and technical brochures

  1. TGP Probe

    2  Pages

  2. Handy Polaris

    2  Pages

  3. Handy pH

    2  Pages

  4. CO2 Analyzer

    2  Pages

  5. Atlantic

    4  Pages

  6. Pond Master

    1  Page

  7. pH Manta

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.