Optima 93225 - 1

Technical Data Sheet Integrated X-ray Source The Optima 93225 is the world’s smallest 50kV, 50W integrated source. The Optima 93225 consists of an integrated, programmable, compact design that contains our eld proven X-ray tube technology, state-of-the-art high voltage power supply and digital controller. The 93225 simplies communication and system integration without the need for high voltage cable connections, making it extremely reliable and cost-effective. It also comes standard with a Beryllium window. Easily integrates into your X-ray systems Fully shielded package Eliminates X-ray leakage XRF Inspection Mining and geology Densitrometry Thickness gauging Regulatory (RoHS/WEEE) Art and archeometry R&D Time to warm up to 50kV and 0.1mA: Continuous stability: Cooling method: Max case operating temp: Ambient operating temp: Radiation leakage: Weight: Storage conditions: X-Ray Technology www.oxford-instruments.com 360 El Pueblo Way Scotts Valley, CA 95066 Phone: (831) 439-9729 Email: sales@oxfordxtg.com Small, compact design Advanced digital interface Simplies communication and system integration Enables maximum lament life Intelligent controller Operating voltage range: Maximum power: Beam current: Target angle: Focal spot size (maximum): Focus to Object Distance (FOD): Target material: Window material and thickness: Cone angle: Input voltage: Input voltage ripple: Maximum current (in-rush): Control signals: Highly repeatable measurements Stable X-ray output *See Drawing 8277 **Note: Barometric Pressure: 50-106kPa Humidity: 10-90% (no condensation) Condensation on Be window will cause window corrosion, vacuum loss, and X-ray tube failure

Open the catalog to page 1
Optima 93225 - 2

Optima 93225 Integrated X-ray Source PIN A AND UNIQUE KEY ON THIS SIDE AMPHENOL CONNECTOR PN: PT02A-12-10P MATING CONNECTOR: PN PT06A-12-10S(SR) #6 PHILLIPS HEAD GROUND SCREW 31.1 1.22 PACKAGE fACE TO X-RAY SPOT. 23° X-RAY CONE ANGLE SIGNAL VOLTAGE INTERLOCK IN +48 5% VCC +48 5% TXN FROM X-RAY SOURCE 0-5 RXN TO X-RAY SOURCE 0-5 RXP TO X-RAY SOURCE 0-5 NO CONNECT INTERLOCK OUT 0-48 OUTPUT 100mA MAX GND 0 TXP FROM X-RAY SOURCE 0-5 visit www.oxford-instruments.com for more information This publication is the copyright of Oxford Instruments plc and provides outline information only, which...

Open the catalog to page 2

All Oxford Instruments X-ray Technology catalogs and technical brochures

  1. Omicron Argus

    12 Pages

  2. UVTouch

    2 Pages

  3. Cypher S

    8 Pages

  4. Cypher ES

    4 Pages

  5. Optima 98017

    2 Pages

  6. Optima 97008

    2 Pages

  7. Optima 97007

    2 Pages