video corpo cad

PLPT9 450LB_E A01
16Pages

{{requestButtons}}

Catalog excerpts

PLPT9 450LB_E A01 - 1

Published by ams-OSRAM AG Tobelbader Strasse 30, 8141 Premstaetten, Austria Phone +43 3136 500-0 ams-osram.com © All rights reserved | 2023-02-16 1 | Version 1

Open the catalog to page 1
PLPT9 450LB_E A01 - 2

PLPT9 450LB_E A01 Blue Laser Diode in TO90 Package Applications - Appliances & Tools - Projection & Display - Static Forward Lighting - Corrosion Robustness Class: 1B - Qualifications: Depending on the mode of operation, these devices emit highly concentrated visible light which can be hazardous to the human eye. Products which incorporate these devices have to follow the safety precautions found in IEC 60825 “Safety of laser products”. - Typical emission wavelength: 447 nm - Efficient radiation source for cw and pulsed operation - TO90 package - ESD protection diode - Laser diode isolated...

Open the catalog to page 2
PLPT9 450LB_E A01 - 3

Ordering Information  Type Peak output power  typ. Popt Ordering Code

Open the catalog to page 3
PLPT9 450LB_E A01 - 4

Maximum Ratings Parameter Operating temperature Storage temperature Junction temperature Peak output power 1) Tcase ≤ 60 °C Reverse current Soldering temperature tmax = 10 sec Operation outside these conditions may damage the device. Operation at the maximum ratings may influence lifetime.

Open the catalog to page 4
PLPT9 450LB_E A01 - 5

Characteristics Popt = 3.5 W; Tcase = 25 °C Parameter Beam divergence (1/e²) parallel to pn-junction Beam divergence (1/e²) perpendicular to pn-junction Threshold current Total power dissipation Thermal resistance junction case real

Open the catalog to page 5
PLPT9 450LB_E A01 - 6

Wavelength Groups Tcase = 25 °C Group Peak Wavelength 3) Popt = 3.5 W min. peak Peak Wavelength 3) Popt = 3.5 W max. peak Forward Current Groups Tcase = 25 °C Group Forward Current 2) Popt = 3.5 W min. IF Forward Current 2) Popt = 3.5 W max. IF

Open the catalog to page 6
PLPT9 450LB_E A01 - 7

Relative Spectral Emission Optical Output Power Forward Voltage Popt = f (IF)

Open the catalog to page 7
PLPT9 450LB_E A01 - 8

Max. Permissible Opt. Output Power Popt = f (Tc)

Open the catalog to page 8
PLPT9 450LB_E A01 - 9

Dimensional Drawing Further Information: Approximate Weight: Corrosion test:

Open the catalog to page 9
PLPT9 450LB_E A01 - 10

Electrical Internal Circuit

Open the catalog to page 10
PLPT9 450LB_E A01 - 11

300 10 s max., max. contact time 5 s per wave Second wave Continuous line: typical process Dotted line: process limits

Open the catalog to page 11
PLPT9 450LB_E A01 - 12

Notes Depending on the mode of operation, these devices emit highly concentrated visible and non visible light which can be hazardous to the human eye. Products which incorporate these devices have to follow the safety precautions given in IEC 60825-1. Subcomponents of this device contain, in addition to other substances, metal filled materials including silver. Metal filled materials can be affected by environments that contain traces of aggressive substances. Therefore, we recommend that customers minimize device exposure to aggressive substances during storage, production, and use....

Open the catalog to page 12
PLPT9 450LB_E A01 - 13

Disclaimer Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version on our website. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it...

Open the catalog to page 13
PLPT9 450LB_E A01 - 14

Brightness: The brightness values are measured with a tolerance of ±11%. Operating/Forward current: IF is measured with an internal reproducibility of ±7 % (acc. to GUM with a coverage factor of k = 3). Wavelength: λpeak is measured with an internal reproducibility of ±0.3 nm (acc. to GUM with a coverage factor of k = 3). Forward Voltage: The forward voltages are measured with a tolerance of ±0.1 V. Typical Values: Due to the special conditions of the manufacturing processes of semiconductor devices, the typical data or calculated correlations of technical parameters can only reflect...

Open the catalog to page 14
PLPT9 450LB_E A01 - 15

Revision History Version Initial Version

Open the catalog to page 15
PLPT9 450LB_E A01 - 16

Published by ams-OSRAM AG Tobelbader Strasse 30, 8141 Premstaetten, Austria Phone +43 3136 500-0 ams-osram.com © All rights reserved

Open the catalog to page 16

All OSRAM Opto Semiconductors catalogs and technical brochures

  1. SFH 4775S

    21 Pages

  2. LG Q976.01

    24 Pages

  3. LE BR Q7WM.0A

    28 Pages

  4. GW CSSRM4.HW

    23 Pages

  5. AS1170

    53 Pages

  6. SFH 4851

    15 Pages

  7. SFH 464

    14 Pages

  8. SFH 4725AS A01

    20 Pages

  9. SFH 4726AS

    19 Pages

  10. LOG T77K

    16 Pages

  11. SFH 4855

    13 Pages

  12. KRTB EKLP42.32

    27 Pages

  13. LRTBGRTG

    26 Pages

  14. LB QH9G

    22 Pages

  15. KR EGLP41.22

    19 Pages

  16. Laser Diodes

    8 Pages

  17. Blue Laser

    9 Pages

  18. Tape and Reel

    34 Pages