MÖBIUS™ Recycler Condensing Liquid Nitrogen HPGe Detector Cooling System “All the advantages of Liquid Nitrogen cooling without the need for frequent refilling

Open the catalog to page 1
Mobius Recycler Condensing Liquid Nitrogen, HPGe Radiation Detector Cooling System - 2

MÖBIUS Introduction The ORTEC Möbius Recycler technology provides “tried and tested” LN2 cooling of your HPGe detector in a system where LN2 requires refilling approximately once every other year under normal, continuous operating conditions. This is achieved by the integration of a Sunpower® cryocooler and a specially designed 28 liter liquid nitrogen dewar. The Möbius Recycler provides an excellent strategy for managing counting laboratories which have periodic power failures. A “smart” cooler controller senses when the Möbius is operating on an uninterrupted power supply (UPS) and...

Open the catalog to page 2
Mobius Recycler Condensing Liquid Nitrogen, HPGe Radiation Detector Cooling System - 3

\S PopTop Dipstick Diameter s'/ Streamline Dipstick Diameter Mobius with Side-Looking Cryostat

Open the catalog to page 3
Mobius Recycler Condensing Liquid Nitrogen, HPGe Radiation Detector Cooling System - 4

Möbius with J-style Cryostat Möbius with HJ-style Cryostat with Remote Preamp 4

Open the catalog to page 4
Mobius Recycler Condensing Liquid Nitrogen, HPGe Radiation Detector Cooling System - 6

Ordering Information Mobius with Dipstick Cryostat MOBIUS-PT Mobius with Side-looking or J-style Cryostat MOBIUS-B CFG-ADAPTOR CLAMP-1.25 Collar adaptor allows use of 1.25” diameter dipstick cryostat. Detector clamp for 1.25” dipstick diameter. CLAMP-1.50 Detector clamp for 1.50” dipstick diameter. MOBIUS Mobius Recycler. Includes 1.5” (38.1 mm) diameter collar. Notes 1) Other Mobius configurations are available as a special order. Contact the factory for more information. 2) Retrofit of an existing customer detector into MOBIUS-B requires the detector to be returned to the factory.

Open the catalog to page 6
Mobius Recycler Condensing Liquid Nitrogen, HPGe Radiation Detector Cooling System - 8

Specifications subject to change 051117 www. ortec-online, com Tel. (865) 482-4411 • Fax (865) 483-0396 • ortec.info@ametek.com 801 South Illinois Ave., Oak Ridge, TN 37830 U.SA For International Office Locations, Visit Our Website