IDM-200 -V Interchangeable HPGe Detector Module (IDM) (■■’•■■•III] iinaat is::::::. “Free from liquid nitrogen, free from maintenance, free from integration complexities AMETEK ADVANCED MEASUREMENT TECHNOLOGY
Open the catalog to page 1• Convenient-to-mount, all-in-one integrated HPGe detector, cooler, cryostat, and signal processing electronics; requires only AC/DC power and a USB connection. • Operates in any orientation. • Standardized large area HPGe crystal dimensions ensures uniform performance unit-to-unit. • Maintenance free. • Hardened cryostat eliminates “partial warm up” problem. • Mains power and DC operation. • Remains operational from internal battery for ~2.5 hours following power failure. Longer battery life options available (external). • Low-power, reliable Stirling-cycle cooler. • ORTEC CONNECTIONS...
Open the catalog to page 2IDM-200-V The IDM-200-V Interchangeable Detector Module from ORTEC is a high performance gamma-ray spectrometry “building block” for use in multiple applications. It is a completely self-contained package, comprising a single, large-area, mechanically cooled high-purity germanium (HPGe) detector of standardized crystal dimensions and all necessary spectrometry electronics in a RUGGED, low-power configuration. The IDM-200-V includes everything needed for the high resolution spectrometry task, producing either a resultant spectrum in memory or delivering a digitized pulse stream in list mode...
Open the catalog to page 3The ~50% relative efficiency HPGe detector in the IDM-200-V is of an “over-square” diameter-to-length profile. The large diameter enhances low energy efficiency. The figures below show the point source absolute efficiency curves of an IDM-200-V in comparison with a more conventionally profiled detector of almost the same relative efficiency (51%). The IDM-200-V shows much higher efficiencies at low to medium energies, where container or matrix absorption effects are possible to be problematic to measurements. See detailed specifications below for more information. Radiation Entrance Window:...
Open the catalog to page 4IDM-200-V Data Collection Modes Data are usually collected by the IDM-200-V in Pulse Height Analysis (PHA) mode and transferred to a PC for further analysis. There is a small dead time when the data are being transferred during which new data are not collected. If absolutely no loss of data is an essential need, then, a solution exists in the form of List mode acquisition. In the List mode of operation, data are stored directly to computer memory, event by event, with a time stamp (200 nanoseconds). These data can then be reconstructed into separate spectra by time, energy, or position....
Open the catalog to page 5Physical Specifications Internal Battery Operating time on internal battery Input Power Power Usage Ambient Temperature Environment Maximum Overall Dimensions Weight Maximum Shock Tolerance Rechargeable, nominal 14.4 V lithium-ion battery pack. Charging circuitry and battery management circuitry internal to the instrument. Battery life 3-5 years. The battery is accessible through a SNAP-open battery door making it easy to exchange and exhausted battery if the situation demands it. ~2.5 hours at 25°C, <4 hour charge time. Operating time may be extended indefinitely by use of external battery...
Open the catalog to page 7Specifications subject to change 031919 www. ortec-online, com Tel. (865) 482-4411 • Fax (865) 483-0396 • ortec.info@ametek.com 801 South Illinois Ave., Oak Ridge, TN 37830 U.SA For International Office Locations, Visit Our Website
Open the catalog to page 8All ORTEC catalogs and technical brochures
-