digiBASE-E High Performance, Digital Gamma Spectrometer A Complete, All-in-One, High Performance Digital Gamma Spectrometer in a PMT Base for Scintillation Detectors. ADVANCED MEASUREMENT TECHNOLOGY

Open the catalog to page 1
DigiBASE-E PMT Base with Digital MCA and Ethernet Connection for NaI and LaBr - 2

digiBASE-E • All-in-one solution for scintillation spectroscopy in a 14-pin tube base based on high performance digital signal processing, suitable for most 10-stage PMTs. • Ideal for most types of scintillation detectors, including NaI(Tl), LaBr3(Ce), etc. • Integral preamplifier, HV, and digital MCA. • Stable up to high count rates; HUGE maximum throughput1 ~200k cps at ~530k cps input count rate. • PHA and List Mode data acquisition plus 32-bit counter input. • Power-over-Ethernet (PoE) makes for ease of system implementation in networks and other applications. (Standard RJ45 connector)....

Open the catalog to page 2
DigiBASE-E PMT Base with Digital MCA and Ethernet Connection for NaI and LaBr - 3

digiBASE-E MCA Emulation and Spectral Analysis MAESTRO MCA Emulator Included The MAESTRO software provides a graphical user interface for all the controls needed to adjust the acquisition parameters, acquire the data, set the master timer digiBASE-E, and save the spectra. MAESTRO is a member of the CONNECTIONS family of ORTEC products, thus providing full networking with other ORTEC spectrometers and supporting computers. Since the digiBASE-E is a TCP/IP device, the IP address must first be defined by running the Ethernet Device Controller, then run the MCB.config program to establish...

Open the catalog to page 3
DigiBASE-E PMT Base with Digital MCA and Ethernet Connection for NaI and LaBr - 4

ROUTE GATE Routes input to spectrum 1 when high (true) and spectrum 0 when low (false). In List Mode this adds a flag to data events generated when this gate is present (cannot be used with R-TIME SYNC). EVENT Rising edges are counted by a 32-bit event counter. The contents of the counter can be monitored on the Status tab in MAESTRO software (cannot be used with R-TIME SYNC). TRIGGER IN Input rising edge starts the acquisition. R-TIME SYNC When multiple digiBASE-E instruments are in List Mode and one digiBASE-E must be designated the R-Time source (Master Timer) for the other systems...

Open the catalog to page 4