Open the catalog to page 120873 Cavenago di Brianza | MB | ITALY phone: +39 02 95 917 800 email: [email protected] VOLTAGE STABILIZERS SAG COMPENSATORS LV TRANSFORMERS AND REACTORS POWER FACTOR CORRECTION SYSTEMS ACTIVE HARMONIC FILTERS ENERGY EFFICIENCY SMART DEVICES ENERGY SAVING VOLTAGE OPTIMIZERS
Open the catalog to page 2ABOUT US Innovative solutions for sustainable power quality since 1969 Founded in 1969, Ortea is a leader in the design and manufacture of innovative products and customised solutions for power quality and energy efficiency. Thanks to a network of offices and dealers on all continents, Ortea products are now installed, maintained and operating in more than 100 countries worldwide. In line with the strategy of creating a global pole of excellence, the new brand Ortea Next is created in 2019, bringing together the 3 historical product brands - Ortea, Icar and Enersolve - in a single concept of...
Open the catalog to page 3MADE IN ITALY Production quality, attention to details, design, and reliability represent the added value of Made in Italy. All the Ortea Next solutions are devised, designed, produced, and assembled in Italy. EXPERIENCE Founded in 1969, Ortea Next has accumulated experience and expertise that have contributed to continuous growth over time, until becoming an authoritative and innovative company in designing and producing power quality solutions on an international scale. RELIABILITY The certified Company Quality System of Ortea Next guarantees the reliability and longevity of the whole range...
Open the catalog to page 4POWER QUALITY SOLUTIONS Paying little attention to the issue of power quality causes problems and damage to equipment and production processes Ortea Next offers a complete range of integrated products and solutions for power quality and energy efficiency, thanks to the synergy between the Ortea Next brands, Ortea, Icar, Enersolve, and Powersines. VOLTAGE VARIATION SAGs / DIPs UNPROTECTED LOADS EXCESSIVE REACTIVE POWER HARMONIC POLLUTION VOLTAGE STABILIZERS ACTIVE HARMONIC FILTERS ENERGY EFFICIENCY SMART DEVICES ENERGY SAVING VOLTAGE OPTIMIZERS
Open the catalog to page 5VOLTAGE IS NEVER PERFECT 60% OF POWER QUALITY COSTS ARE CONSEQUENCE OF VOLTAGE SAGS Modern industry is becoming more automated and the sensitivity of processes to Power Quality events is increasing. It is generally recognized that quality is an important aspect of the electricity service. Not only low prices are important, also high-quality matters to customers. Price and quality are often complementary aspects; together they define the value that customers derive from consuming electricity. In practice the voltage is never perfect. If the quality of electricity supplied to the plants drops below...
Open the catalog to page 6WHAT ARE VOLTAGE SAGS? A voltage SAG is a temporary reduction of the Voltage RMS below a specific threshold at an electrical supply line point. SAG STARTS WHEN VOLTAGE GOES LOWER THAN 90% OF NOMINAL VALUE AND ENDS WHEN VOLTAGE RESUME ABOVE THIS VALUE NOMINAL VOLTAGE RESIDUAL VOLTAGE Generally voltage SAG happens when the residual voltage decreases between 10 and 90 percent of nominal voltage for one-half cycle to one minute. Voltage SAG duration is considered within 10ms up to 1min. The great deal of Voltage SAG have a duration lower than 1 second and a residual voltage higher than 40% of the...
Open the catalog to page 7WHERE DO THE VOLTAGE SAGS COME FROM? MOST VOLTAGE SAGS LAST LESS THAN ONE SECOND AND HAVE A RESIDUAL VOLTAGE EXCEEDING 40% • The voltage SAG propagates from the higher voltage levels to the lower ones, the load is often connected to a voltage level lower than the point of failure. • Faults in the network cause deep voltage SAGs if they occur near loads. • According to an Italian CESI study, the incidence of voltage SAGs is much greater in the case of an aerial MV network than with underground cables. RELEVANCE OF VOLTAGE SAGS VOLTAGE SAG COST IS NORMALLY LOWER THAN A VOLTAGE SUPPLY INTERRUPTION...
Open the catalog to page 8capabilities and limitations of computers and business equipment and their voltage stability requirements. ITI (CBEMA) Curve Percent of Nominal Voltage (RMS or Peak Equivalent) TROUBLES COME: Prohibited Region Voltage Tolerance Envelope Applicable to Single-Phase 120-Volt Equipment 200 OXYGEN ±15% -50% compensation zone No Interruption in Function Region • LOWER THAN 90% OF NOMINAL VOLTAGE AND STARTING FROM 10 SEC • ABOVE 110% OF NOMINAL VOLTAGE AND STARTING FROM 0.5 SEC Duration in Cycles (c) and Seconds (s) SEMI, the industry association for the semiconductor industry, has developed the SEMI...
Open the catalog to page 9Oxygen, thanks to a suitable sizing of the power components and a remarkable response speed (<3 milliseconds) is able to face lowering (SAG) of the grid voltage of a maximum duration of one minute. The energy required is taken directly from the network. Current models are able to cover network downing up to 50% of the nominal value (-50%). The voltage compensation on the buck/boost primary winding is performed by IGBT static switches controlled by a microcontroller. The microcontroller system monitors the output voltage and determines the opening or closing of the IGBT contacts ensuring the best...
Open the catalog to page 13SAG CORRECTION UP TO -50% WITH CONTINUOUS ONLINE REGULATION UP TO ±15% Correction in less than 3 millisecs. HIGH EFFICIENCY INDUSTRIAL DESIGN Designed for standard industrial loads. MODULAR CONSTRUCTION Fast & Easy maintenance. Protection from the most common Power Quality problem. Voltage SAGs are the most common cause of equipment malfunctions in automated industry. SAGs correction up to -50% for 1 min. Economical solution: no maintenance and operation costs. No battery energy storage required. Efficiency >98%. WITHOUT ENERGY STORAGE Minimum maintenance and increased reliability. Oxygen solution...
Open the catalog to page 14Available nominal voltage* Maximum supply voltage Frequency Power system 380-400-415V (440-460-480V 60Hz only) Max continuous voltage +10% 3 phases + N (no neutral wire on request) Admitted load variation Admitted load imbalance Admitted overload Harmonics The same of input nominal voltage (output voltage can be adjusted) 110% continuous, 120% for 1 minute (>120% electronic by-pass intervention) Harmonics tolerance according to IEC 61000-2-4 Class 2 (THDv < 8%)** SAG correction response Output voltage accuracy SAG correction accuracy Continuous regulation range SAG correction capability Oxygen...