About Ortea Next
Ortea Next, established in 1969, is a leader in power quality and energy efficiency solutions, with a global presence in over 100 countries. The company focuses on innovation, customization, and continuous improvement, offering products under the brands Ortea, Icar, and Enersolve. All products are designed and manufactured in Italy, ensuring high quality and reliability.
Experience and Reliability
Ortea Next is recognized for its expertise in power quality solutions, supported by a certified quality system that ensures product reliability and longevity. The company offers tailored solutions to meet specific client needs and provides support throughout the project lifecycle.
Research & Development
Continuous collaboration with academic and technological partners drives innovation in product development. Ortea Next’s quality system is certified to ISO 9001, ISO 14001, and ISO 45001 standards, ensuring optimized performance and attention to environmental and safety issues.
Power Quality Solutions
Ortea Next provides comprehensive solutions for power quality issues, including voltage stabilizers, power factor correction systems, and harmonic filters. Correcting power factor can eliminate financial penalties, reduce energy waste, and improve the efficiency of electrical systems.
Services Offered
Ortea Next offers services from system selection to maintenance, ensuring optimal performance and longevity of power factor correction systems. The document includes a glossary explaining key terms related to power factor correction.
Technical Specifications and Guidelines
The document provides detailed guidelines on the use, installation, and maintenance of power factor correction equipment, focusing on safety, compatibility, and operational standards. Capacitors are designed according to IEC-CEI EN standards and must be rated for higher voltages due to potential overvoltage conditions. Safety involves identifying and mitigating risks, and specific installation recommendations are provided.
Operational Conditions and Maintenance
Capacitors should not exceed nominal voltage, and specific overvoltage conditions are outlined. Regular maintenance includes cleaning, visual inspections, and checking connections. Equipment should be stored in original packaging in a dry place.
Power Factor Correction Sizing and Calculation
The document outlines methods for sizing power factor correction equipment based on system requirements. It provides a process for calculating the power factor and determining the necessary reactive power. An example calculation is provided for adjusting reactive power requirements.
Capacitor Models and Performance
The document discusses the selection of capacitors for power correction systems, emphasizing quality and robustness. It describes two types of capacitors with key features such as increased power density and improved voltage surge resistance.
Automatic Power Factor Correction Banks
The document details components and solutions for automatic power factor correction banks, highlighting the importance of quality in capacitors and other components. Various models of power factor correction systems are described, each tailored for different power capacities and features.
Thyristor Switched Capacitor Banks and Tuned Filters
The document explains the advantages of thyristor switched capacitor banks and the use of tuned filters for harmonic filtering in power factor correction systems.
Selection Criteria
The document concludes with guidance on selecting power factor correction equipment based on system design data, emphasizing the importance of evaluating the specific needs of the plant.
Reactive Power Regulators
The document provides detailed technical specifications and functionalities of various reactive power regulators used for automatic power factor correction in electrical systems. It includes specifications, alarms and safety features, display and user interface, communication and expandability, performance and capabilities, and protection functions.
Specifications and Monitoring
The document discusses the MCP5 module for monitoring harmonic currents affecting capacitors and enhancing the precision of harmonic content evaluation. It also covers communication functions and the importance of power factor correction in electrical circuits.
Technical Notes on Power Factor Correction
The document outlines the technical and economic advantages of installing capacitor banks and provides formulas for calculating the required capacitor bank size. It discusses the impact of harmonics on power factor correction and provides solutions using detuned filters to avoid resonance.
See more

Catalog excerpts

PFC system-1

Innovative solutions for sustainable power quality since 1969 LV POWER FACTOR CORRECTION SYSTEMS

 Open the catalog to page 1
PFC system-2

20873 Cavenago di Brianza | MB | ITALY phone: +39 02 95 917 800 email: [email protected] VOLTAGE STABILIZERS SAG COMPENSATORS LV TRANSFORMERS AND REACTORS POWER FACTOR CORRECTION SYSTEMS ACTIVE HARMONIC FILTERS ENERGY EFFICIENCY SMART DEVICES ENERGY SAVING VOLTAGE OPTIMIZERS

 Open the catalog to page 2
PFC system-3

ABOUT US Innovative solutions for sustainable power quality since 1969 Founded in 1969, Ortea is a leader in the design and manufacture of innovative products and customised solutions for power quality and energy efficiency. Thanks to a network of offices and dealers on all continents, Ortea products are now installed, maintained and operating in more than 100 countries worldwide. In line with the strategy of creating a global pole of excellence, the new brand Ortea Next is created in 2019, bringing together the 3 historical product brands - Ortea, Icar and Enersolve - in a single concept of...

 Open the catalog to page 3
PFC system-4

MADE IN ITALY Production quality, attention to details, design, and reliability represent the added value of Made in Italy. All the Ortea Next solutions are devised, designed, produced, and assembled in Italy. EXPERIENCE Founded in 1969, Ortea Next has accumulated experience and expertise that have contributed to continuous growth over time, until becoming an authoritative and innovative company in designing and producing power quality solutions on an international scale. RELIABILITY The certified Company Quality System of Ortea Next guarantees the reliability and longevity of the whole range...

 Open the catalog to page 4
PFC system-5

POWER QUALITY SOLUTIONS Paying little attention to the issue of power quality causes problems and damage to equipment and production processes Ortea Next offers a complete range of integrated products and solutions for power quality and energy efficiency, thanks to the synergy between the Ortea Next brands, Ortea, Icar, Enersolve, and Powersines. VOLTAGE VARIATION SAGs / DIPs UNPROTECTED LOADS EXCESSIVE REACTIVE POWER HARMONIC POLLUTION VOLTAGE STABILIZERS ACTIVE HARMONIC FILTERS ENERGY EFFICIENCY SMART DEVICES ENERGY SAVING VOLTAGE OPTIMIZERS

 Open the catalog to page 5
PFC system-6

THE 4 REASONS TO HAVE POWER FACTOR CORRECTIONS Electricity Authorities Economic convenience Energy efficiency Power quality The Electricity Authorities, force companies distributing electricity to apply financial penalties to utilities that have a substantial contractual power and low energy cos phi (generally 0,9). The correct power factor of the electric plant allows you to avoid those penalties, which often are not reflected in the bill, and then are paid by the final user without even realizing it. Economical benefits due to penalties elimination and current reduction, with consequent optimized...

 Open the catalog to page 6
PFC system-7

SERVICES It is particularly convenient to install an effective power factor correction system, correctly sized It is essential to monitor the proper functioning because if you do not keep them in perfect working order, they “lose power”, and you are likely to pay penalties. With proper maintenance you can avoid wasting money and unnecessary power dissipation in the electric plant cables and transformers that undergoes premature aging It is also important a proper maintenance and use of original spare parts since capacitors, when worn or of poor quality, are likely to burst causing damage to electrical...

 Open the catalog to page 7
PFC system-8

Simplifying, in an electrical system is appointed with phi (φ), the phase shift between the voltage and the electric current at the fundamental frequency of the system (50Hz). The cos phi is therefore a dimensionless number between 0 and 1, and varies from moment to moment. Typically, an industrial electrical system has an inductive cos phi, which value depends on the characteristics of the user plant. Power factor They are the physical units (racks) of power factor bank. A rack may be constituted by a single step or more steps. The number of contactors on the front of the rack indicates the...

 Open the catalog to page 8
PFC system-9

We define safety the absence of dangers for people and things while the good is in use or stored in a warehouse. This means to identify stresses, risks and potential damages and the relevant elimination and to keep them under control so that to reduce the risk to a reasonable level Power capacitors and capacitor banks shall NOT be used: • for uses other than Power Factor Correction and for AC or DC plants; • as tuned or detuned filters unless specifically approved in written by Ortea Next. General requirement The capacitors are constructed in accordance with IEC-CEI EN methods, parameters and...

 Open the catalog to page 9
PFC system-10

Overpressure devices All the capacitors have an overpressure device which when operated, as in the case of breakdown, disconnects the element from use. This device is not a substitution for the fuses or external circuit-breakers that are specified in our power factor correction equipment. The influence of each factor below has not to be considered individually, but in combination and with the influence of other factors. Capacitor and capacitor bank nominal voltage is intended as the design and testing voltage. The safe and proper use of power factor correction capacitors and capacitor banks,...

 Open the catalog to page 10
PFC system-11

Particular ambient conditions Power factor correction equipment are not suitable for the applications in places where there are conditions as follows: • fast generation of mould; • caustic and saline atmosphere; • presence of explosive materials or very flammable; For environments with these characteristics: high relative humidity, high concentration of dust and atmospheric pollution, please contact technical assistance. After the disconnection of the bank, prior to accessing the terminals of the capacitors wait 5 minutes and then shortcircuit the terminals and earth. Periodically make these...

 Open the catalog to page 11
PFC system-13

SIZING AND SELECTION CRITERIA 14 CALCULATION OF POWER FACTOR CORRECTION STARTING FROM ENERGY BILL__15 CAPACITORS MODELS AND PERFORMANCES WITHIN POWER CORRECTION SOLUTIONS_17 SOLUTIONS AND COMPONENTS OF AUTOMATIC POWER FACTOR CORRECTION BANKS 18 POWER FACTOR CORRECTION SOLUTIONS WITH HIGH GRADIENT METALLIZED POLYPROPYLENE CAPACITORS 27 POWER FACTOR CORRECTION SOLUTIONS WITH HIGH GRADIENT METALLIZED POLYPROPYLENE PLUS CAPACITORS 43 REACTIVE POWER REGULATOR 59