Catalog excerpts
Medium Voltage Switchgear Medium Voltage Switchgear up to 24 kV, 1250 A
Open the catalog to page 1Medium-Voltage Switchgear up to 24 kV, SF6-insulated, Modular Design, Type GAE, Series GAE1250 modular switchgear assemblies 3 Key to type references of sections 5 Key to add-on type references 5 Cable connection compartments 6 Cable retention brackets 6 SF6 the insulating and arc quenching medium 8 Switchgear panels (rated values) 9 GNVL vacuum circuit-breaker with stored energy Three-position isolating switch in the current path Three-position load-break switches (rated values) 11 Three-position circuit-breaker with stored energy operated OFF (rated values) 12 Earthing switch (rated...
Open the catalog to page 2Medium-Voltage Switchgear up to 24 kV, SF6-insulated, Modular Design, Type GAE, Series GAE1250 General Information/Description General Information/Description Benefits of SF6-insulated, metal-encapsulated, modular switchgear assemblies With the GAE1250 series switchgear assemblies, Ormazabal Systems Division meets the international requirements of its customers for SF6-insulated switchgear. Largely climate resistant • In buildings with medium-voltage network infrastructure, e.g. in railway stations, department stores, hospitals, barracks, law courts, administrative buildings, etc. –...
Open the catalog to page 3Medium-Voltage Switchgear up to 24 kV, SF6-insulated, Modular Design, Type GAE, Series GAE1250 General Information/Description Variants of bus-sectionalizer and riser panels Bus-sectionalizer circuit-breaker panel -1LSVG- Bus-sectionalizer circuit-breaker panel -1LSVG- Outgoing circuit-breaker panel -1LSV- and and busbar riser panel with isolating switch -1HT- and metering panel as busbar panel -1M1 - cable riser panel-1 AT- with cable bridge
Open the catalog to page 4Medium-Voltage Switchgear up to 24 kV, SF6-insulated, Modular Design, Type GAE, Series GAE1250 General Information/Description Key to type references of panels © Rated busbar current: ® Rated outgoer current: ® Rated short-time current: Gas-insulated Expandable -1LSV- = outgoing panel with vacuum circuit-breaker -1LSVG- = bus-sectionalizer panel with vacuum circuit-breaker -1HT- = busbar riser panel with isolating switch -1AT- = cable riser panel with isolating switch -1LSF- = outgoing panel with circuit-breaker based on arc quenching coil -1K- = cable panel with load-break switch -1TS- =...
Open the catalog to page 5Medium-Voltage Switchgear up to 24 kV, SF6-insulated, Modular Design, Type GAE, Series GAE1250 General Information/Description The HV compartment This is a gas-tight welded tank made from stainless steel, which houses all the live parts including the busbars. The incoming and outgoing power feeders, as well as the connection of the fuses is made through cast-resin bushings that are individually tested for maintenance of the maximally admissible partial discharge values (TE ï 2 pC). Each HV compartment is equipped with a stainless steel bursting membrane that is specifically designed for the...
Open the catalog to page 6Medium-Voltage Switchgear up to 24 kV, SF6-insulated, Modular Design, Type GAE, Series GAE1250 General Information/Description Voltage transformer Current transformer Plug-in, metal-encapsulated, single-pole voltage transformers to IEC 60044-2 and VDE 0414 Part 2 are optionally flanged directly above the gas tank to the bus-sectionalizer panels with vacuum circuit-breaker -1LSV(G)-/6/, the riser sections -1HT-/6/ and the cable riser sections -1AT-/6/. In outgoing panels and bus sectionalizer panels with circuitbreakers and those with load-break switches, low-voltage ringand spectacle-core...
Open the catalog to page 7Medium-Voltage Switchgear up to 24 kV, SF6-insulated, Modular Design, Type GAE, Series GAE1250 SF6 the insulating and arc quenching medium SF6 the insulating and arc quenching medium Sulphur hexafluoride (SF6) gas has in recent years increasingly found its way also into medium-voltage load switching systems, having been previously successfully used mainly in circuitbreakers up to highest voltage levels. The high operational safety of the system (external influences such as humidity, conductive dust, etc. have no effect) virtually excludes arc-faults. Should such a fault nevertheless occur,...
Open the catalog to page 8Medium-Voltage Switchgear up to 24 kV, SF6-insulated, Modular Design, Type GAE, Series GAE1250 Technical Data Technical Data Switchgear panels (rated values) Rated voltage Ur 7.2 kV 12 kV Rated insulation level Rated power-frequency withstand voltage, AC Ud Rated lightning impulse withstand voltage Up Rated frequency fr Rated normal current Ir Rated short-time current Ik Rated peak withstand current Ip Rated short-circuit making current Ima Relative humidity Rated filling pressure of insulating gas at 20 °C and 101.3 kPa 130 (30 kPa overpressure)/LSF panel 150 (50 kPa overpressure) With...
Open the catalog to page 9Medium-Voltage Switchgear up to 24 kV, SF6-insulated, Modular Design, Type GAE, Series GAE1250 Technical Data GNVL vacuum circuit-breaker with stored energy operated ON and OFF Rated voltage Ur Rated normal current of the feeder circuits Rated short-time current Rated peak withstand current Rated short-circuit making current Rated short-circuit breaking current Rated cable-charging breaking current Peak value Rated transient recovery voltage Pole factor Mechanical operations Class Insulating medium Quenching medium Motor-Spring-operated stored energy mechanism Number of isolating gaps per...
Open the catalog to page 10Medium-Voltage Switchgear up to 24 kV, SF6-insulated, Modular Design, Type GAE, Series GAE1250 Technical Data Three-position load-break switches (rated values) Rated voltage Ur Cable panel -1K-, transformer outgoing panel -1TS- Ring cable feeder circuits Ring cable feeder circuits Rated peak withstand Rated normal current for Rated short-circuit making current for Switching capacity for multi-purpose load-break switches to IEC 60265-1 and VDE 0670 Part 301 Test sequence 1 Rated mainly active load-breaking current Rated distribution line closed-loop breaking current, 10 % Rated...
Open the catalog to page 11Medium-Voltage Switchgear up to 24 kV, SF6-insulated, Modular Design, Type GAE, Series GAE1250 Technical Data Three-position circuit-breaker with stored energy operated OFF (rated values) Rated voltage Ur Outgoing panel with SF6 circuit-breaker -1LSFSwitching capability acc. to IEC 62271-100, test duty I100a is not required Rated peak withstand current Rated short-circuit making current Rated short-circuit breaking current Rated cable-charging breaking current Rated switching sequence Rated normal current of the feeder circuits Rated short-time current Operations at Rated short-circuit...
Open the catalog to page 12