Light Duty Chiller with Built-In Water Tank
36Pages

{{requestButtons}}

Catalog excerpts

Light Duty Chiller with Built-In Water Tank - 1

Light Duty Chiller with Built-In Water Tank Cooling Capacity: 2.7 ∼ 8.7kW(Air cooled) 6.0、10.4kW(Water cooled) The ORION 3-series chiller lineup has the right chiller to meet your diversified needs Light Duty Chiller with Built-In Water Tank Catalog Striving to Make Product

Open the catalog to page 1
Light Duty Chiller with Built-In Water Tank - 2

Choose Your ORION Built-In Water Tank Chiller! Price Performance Position of 3 Series of Chillers With our 3-Series Lineup, we have the best chiller to balance your needs and budget. Energy-Saving, Precision Control, High-Spec Initial Cost HighSpec. Model High Energy Savings and Precision Control (±0.1 °C) Ambient Temp.: Operable Temperature Range (Liquid temp.): Control: -5 – 43 °C (Air Cooled) 2 – 43 °C (Water Cooled) 5 – 35 °C ±0.1°C High Precision Temperature Control MidGrade Model RKS-GM Series Ambient Temp.: Operable Temperature Range (Liquid temp.): Control: RKS-JM Series RKE Series...

Open the catalog to page 2
Light Duty Chiller with Built-In Water Tank - 3

3-Series Lineup High-Spec Model Inverter control gives improved energy savings and high-precision temperature control. Series Air / Water Cooled Water cooled Control Accuracy Power Source kW Cooling Capacity*2 (50 / 60Hz) Flow Rate *1 G1 spec. also available without casters. *2 For operation on air-cooled machines when the chilled water temperature is 20 °C and the ambient temperature is 25 °C, or for watercooled machines when the chilled water temperature is 20 °C and the cooling water temperature is 32 °C. Cooling capacity is at least 95% of listed figures. Mid-Spec Model Series Air /...

Open the catalog to page 3
Light Duty Chiller with Built-In Water Tank - 4

Application Examples by Series High Energy Savings and Precision Control (±0.1 °C) RKE Series Fiber Laser Diode laser oscillator and optical systems cooling. Helium compressor cooling and gradient coil cooling. High Frequency Induction Heating Plasma Welder Heating coil cooling and high frequency power supply cooling. Cooling for power supply and welding torch. Photolithography Equipment ±0.1°C cool water supply for exposure stage (cool plate). Improved cooling efficiency for inspection solutions. RKE Series Economy Models Offer Low Price in a Compact Design AND High Precision Temp. Control...

Open the catalog to page 4
Light Duty Chiller with Built-In Water Tank - 5

RKS-J Series Milling Equipment Jacket cooling. Jacket cooling. Spot Welding Machine Electrode and power supply cooling. Vacuum Vapor Deposition Equipment Power Supply and Torch Cooling. Chamber cooling. Laboratory Furnace/Kiln Packing Machinery Cooling after heat sealing. Furnace/kiln cooling. Dual Channel Chiller Lineup for Fiber Laser Independent water circuits in a single chiller package provide different temp. settings for the oscillator and optical system. Please see the catalog for more detail. 10 Lineup: Dual Channel Chiller for Fiber Laser Resonator Output Cooling Capacity Operable...

Open the catalog to page 5
Light Duty Chiller with Built-In Water Tank - 6

High Energy Savings and Precision Control (±0.1 °C) * Warranty period of the refrigerant circuitis 2 years from the date of purchase * CE compliance is available via special order. (or 10,000 hours of operating time). Fully Loaded with Superior Functionality to Meet All the Requirements of Your Application and Working Environment. High-Spec Model 2.7kW – 8.7 kW(Air Cooled) 6.0kW – 10.4 kW(Water Cooled) Ambient Temp. Range: -5 – 43 °C(Air Cooled) 2 – 43 °C(Water Cooled) Operable Temp. Range (Liquid temp.): Temp. Control Precision: Minimum 30 % Energy Savings* AND Precise Temperature Control...

Open the catalog to page 6
Light Duty Chiller with Built-In Water Tank - 7

Built for Improved Ease of Use Tank access is at the top for easy access, easy water quality confirmation, easy cleaning! Slanted front panel design is easy to see and easy to operate. Easy "One Touch" removable condenser dust filter. (Air cooled model only) Wealth of Accessories (Sold Separately) and Multi-Function Parameters Operation and control functions, as well as water temperature control conditions monitoring all from your PC via a single cable hookup. Equipped with a Wealth of Accessories (Sold Separately). Users have many options to choose from such as Remote control, Heaters,...

Open the catalog to page 7
Light Duty Chiller with Built-In Water Tank - 8

High Energy Savings and Precision Control (±0.1 °C) RKE Series Specifications Chart Model Performance Specifications Power Specifications Cooling Capacity Room Temp. 32 °C, Set Temp. 20 °C*1 Room Temp. 25 °C, Set Temp. 20 °C Ambient Temp. Range Operating Temp. Range (Liquid Temp.) Control Precision -5 – 43 5 – 35 ±0.1 (Under stable load, ambient temperature and power source.) ±0.5 (When the current load is continuously within ±10%.) Min. Operating Circulation Rate (50/60 Hz) Breaker Capacity 10 (With heater installed: 15) Current sensitivity: 30 mA, High-speed 15 (With heater installed: 20)...

Open the catalog to page 8
Light Duty Chiller with Built-In Water Tank - 9

Conditions • Room Temp.: 32 °C • Chilled Liquid: Water • Discharge Pump Circulating Load: 10 L/min Conditions • Ambient and Cooling Water Temp.: 32 °C • Chilled Liquid: Water • Discharge Pump Circulating Load: 12/21 L/min Conditions • Ambient and Cooling Water Temp.: 32 °C • Chilled Liquid: Water • Discharge Pump Circulating Load: 39/54 L/min Minimum Heat Requirement for Inverter Control Chilled Liquid: Water * Even in the high accuracy mode, if the amount of heat to process is below the minimum level, the compressor will cycle ON and OFF, and may affect the control accuracy. * If the...

Open the catalog to page 9
Light Duty Chiller with Built-In Water Tank - 10

High Energy Savings and Precision Control (±0.1 °C) RKE Series External Dimensions (Units: mm) Water Supply Port Access Hole (Rc 1/2 for Accessory(Sold Separately) ball tap) 4 M8 nuts (For Accessory(Sold Separately)eye bolt installation.) Handle to Open and Close the Water Tank Liquid Level Gauge Ventilation Direction Panel Anchoring Hardware G1: 4 Locations, G2: 2 Locations in Opposite Angles (For transport. Remove before operation.) 4 M8 nuts (For Accessory(Sold Separately) water filter installation) Water Tank Cover Water Tank Drain Valve Detail of Chilled Water Circuit Parts Bypass...

Open the catalog to page 10
Light Duty Chiller with Built-In Water Tank - 11

4 M8 nuts (For Accessory(Sold Separately)eye bolt installation.) Water Supply Port Access Hole (Rc 1/2 for Accessory(Sold Separately)ball tap) Water Tank Drain Valve 4 M8 nuts (For Accessory(Sold Separately) water filter installation) Cooling Water Inlet Rc 3/4 120 Cooling Water Drain Rp 1/4 (w/ plug) 87 Wiring Access Hole (Φ38) Freeze-Prevention Valve (Accessory(Sold Separately): For heater.) Water Pressure Gauge Cooling Water Outlet Rc 3/4 Refrigerant High-Pressure Gauge Overflow Water Tank Drain Rp 1/2 Handle to Open and Close the Water Tank Operation Panel Liquid Level Gauge Anchoring...

Open the catalog to page 11