Overview: The document is a catalog for ORION Unit Coolers, specifically the RKS and RKL series, designed for industrial, agricultural, and food applications. These units provide efficient cooling solutions without water tanks.
Specifications: The units feature stainless steel coil type heat exchangers resistant to clogging. Cooling capacities range from 0.59/0.62 kW to 4.30/4.65 kW for the RKS series and 7.9/8.5 kW to 25.0/27.1 kW for the RKL series. They operate with three-phase 200 V or single-phase 100 V power supplies, suitable for ambient temperatures between 5 to 40°C and liquid temperatures from 5 to 25°C.
Features: Key features include built-in circulation pumps, digital temperature control, and external signal terminals. The units are compact, with controls concentrated on the front panel, equipped with multi-directional vents, and use high-efficiency refrigerants like R134a, R407C, and R410A.
Applications: The ORION Unit Coolers are used in various sectors: industrial (cooling tanks on extrusion machines, machine tool tank-water cooling, concrete production), agriculture (temperature management for hydroponics, shiitake mushroom log cover-water cooling), and food (cooling after vacuum packing, canned food cooling, food container cooling).
Performance and Construction: Designed to minimize clogging, the units can be disassembled for cleaning. They include features like a condenser filter and are rated for multiple power sources. Construction materials include ABS and SUS304 for durability.
Installation and Maintenance: The units are designed for easy installation with a low profile and concentrated control layout. They require a minimum water tank capacity, and the recommended chilled liquid is either clean water or a 30-40% industrial-use ethylene glycol solution.
Introduction: This document provides technical specifications and operational guidelines for the ORION IoT System and Unit Coolers, including details on refrigerants, temperature control, remote monitoring, and installation requirements.
Procedures: Instructions for downloading IoT software are provided, emphasizing that the software is available only in Japanese. The document describes the process for remote monitoring of ORION products, including email alerts for alarm conditions.
Standards and Ratings: The equipment is rated for IPX3, indicating splash-proof capabilities. It can operate with multiple power sources and includes features like digital temperature control and external signal terminals.
Recommendations: For optimal operation, consider the piping design to maintain prescribed resistance limits. The document advises selecting the appropriate model based on cooling capacity and operational requirements.
Key Data and Calculations: The document includes calculations for determining the amount of heat generated by equipment and the required cooling capacity, with examples of piping resistance calculations and head loss within PVC pipes.
Optional Features and Customization: Various optional features and customizations are available, such as special coatings, leak detectors, and different display languages. The document lists standard and special-order specifications for unit coolers.
Conclusion: This comprehensive guide ensures that users can effectively utilize ORION's cooling systems by understanding the specifications, installation requirements, and operational procedures.
Product Use Limitations: Failure to adhere to warnings may result in death or serious injury. The equipment should be installed in a level, vibration-free area that can support its weight. Safety devices and backup systems are recommended for critical installations.
Installation and Operation: Use rust-resistant piping and install a foot valve and strainer to prevent foreign matter intake. Ensure proper drainage and avoid using pure or treated sewage water. Maintain a clearance of 80cm around the unit and 200cm above for optimal performance.
Water Quality Standards: Cooling water should meet specific quality standards to prevent corrosion and scaling. Key parameters include pH, electrical conductivity, and ion concentrations. Regular water replacement is advised to maintain quality.
Maintenance and Inspection: Monthly checks for water cleanliness and condenser condition are necessary. Clean inverter cooling fans every six months and inspect pumps for leaks. Ensure power is applied 12 hours before initial test runs.
Model Specifications: Various models are available with different cooling capacities and control precision. Power sources vary between single-phase and three-phase, with specific requirements for each model.
Refrigerant Management: HFC refrigerants are used, requiring careful management to prevent environmental impact. Regular cleaning of condensers is essential to maintain efficiency and prevent damage.
Safety and Compliance: Read the operating manual thoroughly and ensure installation by qualified personnel. Use the equipment only for its intended purpose to avoid accidents or breakdowns.
Maintenance and Inspection: Regular water quality checks are essential for optimal performance. Extended use may lead to dirt accumulation or wear, reducing efficiency. Regular inspections and customer maintenance are recommended, with service and inspection fees applicable. For more details, contact your dealer or ORION directly.
Repair and Warranty: For equipment repairs post-warranty, customers are responsible for charges. Service procedures to improve function are available upon customer request.
Spare Parts Policy: ORION maintains a stock of replacement parts for seven years after product discontinuation to ensure functionality.
Global Presence and Certifications: ORION operates globally, with ISO9001 and ISO14001 certifications at its Main, Koshoku, and Chitose Plants. The company supports the Sustainable Development Goals (SDGs).
See more

Catalog excerpts

Chiller Unit without Water Tank-1

冷熱と真空でイノベーション Innovating with Thermal Control and Vacuum Chiller Unit without Water Tank RKL Series Cooling Capacity: 7.9/8.5 kW to 25.0/27.1 kW ORION UNIT COOLER Adopted stainless steel coil type heat exchanger which is hard to clog Jan.2023 D-RG12E Chiller Unit without Water Tank Catalog

 Open the catalog to page 1
Chiller Unit without Water Tank-2

Unit Cooler Series Configurations ORION Unit Coolers have built-in circulation pumps, so by simply connecting to an open-type water tank and priming with water, tank water can be circulated and maintained at a set temperature. Compact, Water Cooled Power Supply Compact Unit Cooler Operable Ambient Operable Liquid Cooling C) C) Temp (° Temp Range (° Capacity (kW) Req. Water Tank Capacity (L) 25 or more 35 or more 60 or more 35 or more * The RKS1500F model can be used with three-phase 200 V at 50/60 Hz, or three-phase 220 V at 60 Hz. Model RKL-2200-D RKL-3750-D Heavy Duty, Air Cooled RKL-5500-D...

 Open the catalog to page 2
Chiller Unit without Water Tank-3

RKS / RKL Series Here are Just Some Examples of Applications for the ORION Unit Cooler Application Example (For illustration purposes) Industrial Applications · Temperature Management for Cooling Tanks on Extrusion Machines · Machine Tool Tank-Water Cooling · Water for Concrete Production Food Applications · Cooling After Vacuum Packing · Canned Food Cooling · Food Container Cooling *Cannot be used for water that comes in direct contact with food. Agriculture Applications · Liquid Fertilizer Temp. Management for Hydroponics · Water Tank Cooling for Shiitake Mushroom Log Cover-Water Other · Water...

 Open the catalog to page 3
Chiller Unit without Water Tank-4

RKS Series Built-In Circulation Pump External Signal Terminals Digital Temperature Control MultiDirectional Vent Rated for 3 Power Sources Condenser Filter Included Unit Cooler RKS Series High Efficiency Refrigerant R410A 1. Built with a heat exchanging coil that inhibits clogging and can be disassembled when required. Chillers that use external water tanks are susceptible to foreign substances entering the system. With Orion's distinctive heat exchange coil system, there is less likelihood of clogging and yet, in the unlikely chance that clogging does occur, the coil can be disassembled for...

 Open the catalog to page 4
Chiller Unit without Water Tank-5

side) (front side) (When vent cover panel is installed on top.) Control panel Condensing Pressure Cooling Water Gauge Outlet (Rc1/2) Handle Cooling Water Inlet (Rc1/2) Cooling Water Drain (1/4plug) Drain Port R3/8 Incl cap Characteristic Curves Total Head(m) Min. Working Circulation Rate Min. Working Circulation Rate Total Head(m) 175 Closed grommet included Total Head(m) Power Cable Pump-priming Access Hole(φ30) Port (female thread) Control panel Control panel Drain Port M10 (female thread) Dimension W H A Power Cable Access Hole(φ30) Closed grommet included Exhaust Handle Exhaust Power Cable...

 Open the catalog to page 5
Chiller Unit without Water Tank-6

Cooling Capacity: 7.9/8.5 kW to 25.0/27.1 kW Rated for 3 Power Sources Condenser Filter Included External Signal Terminals Digital Temperature Control Built-In Circulation Pump Unit Cooler RKL Series IPX3 Equiv. Rating Splash-proof 1. Built with a heat exchanging coil that inhibits clogging and can be disassembled when required. Chillers that use external water tanks are susceptible to foreign substances entering the system. With Orion's distinctive heat exchange coil system, there is less likelihood of clogging and yet, in the unlikely chance that clogging does occur, the coil can be removed...

 Open the catalog to page 6
Chiller Unit without Water Tank-7

4-Eye Bolts (M10) Control Panel Refrigerant High-pressure Gauge Refrigerant Low-pressure Gauge Chilled Water Inlet Rp 3/4 Water Drain Rp1/2 (with plug) Chilled Water Outlet Rc 1 230 216 Power Cable Access Hole (φ38) *1 For anchor fixation *2 RKL-2200-B1 hole pitch sizes are compatible with this chiller. When upgrading from RKL-2200-B1, please use the pitch sizes listed here. Control Panel Filter (Both sides) Air Intake Refrigerant High-pressure Gauge Refrigerant Low-pressure Gauge Chilled Water Outlet Rc 1 267.1 Water Drain Rp1/2 (with plug) Chilled Water Inlet Rc 1½ Drainpan Drain R1/2 Power...

 Open the catalog to page 7
Chiller Unit without Water Tank-8

Introducing the ORION IoT System / Unit Cooler Specification Items Remote Monitoring Free Cooling Chiller Pneumatic Systems Equipment Air Dryer Auto Drain Trap Remote Operation Precision Air Processor of ORION Products. Uses your factory's internal network for safety against leaks of internal information. Compatible Models Management Office Oil-Free Vacuum Pumps Remote Monitoring Monitoring Software Includes Mail-Alert Functionality Monitoring of product operating states from remote sites is possible. Can be used as long as contact outputs are non-voltage contacts. Get email alerts when alarms...

 Open the catalog to page 8
Chiller Unit without Water Tank-9

Unit Cooler Special-Order Specifications and Optional Parts List ○:Optional equipment ×:Not compatible No. 1 2 3 Requirement 1 Cooling liquid replacement Operable liquid temperature range Power source (Using a transformer) *3 *4 Pump specifications *1 Casters *5 ●:Available by Special Order Standard:Standard configuration Requirements Specification Options Requirement 2 Requirement 3 Wetted parts are Deionized water copper-free * 1, * 13 (up to 1 μ S/cm) High liquid 10 to 30℃ temperature 380V 400V 415V 440V 480V Pump pressure (at pump outlet) With stopper With leveling foot Custom coating (Regarding...

 Open the catalog to page 9
Chiller Unit without Water Tank-10

Connection Methods and Model Choice ■Unit Cooler Series) Cooler Connection Examples Working Principles Pump-priming Port Water Tank Machine Tool Condenser Dryer Capillary tube Fan motor Heat exchanger Check Valve(Foot valve) The circulation pump pumps in liquid from the water tank and then through the heat exchanger. There, the liquid is cooled and then returns to the tank. This cycle is repeated and the liquid is continuously cooled until it reaches the desired set temperature, at which time the temperature regulator shuts off the chiller. And if the liquid temperature rises above the set control...

 Open the catalog to page 10
Chiller Unit without Water Tank-11

RKS / RKL Series 2. Piping Resistance Calculations Piping methods and other particulars have a large effect on the flow rate, head, and resistance of the water cycle. Furthermore, safety devices may also be operating, so it is important to install a piping design that can keep within the prescribed piping resistance (head) limitations. The following describes how to calculate the head of a system. Hm = Total head ha = actual head (the difference in height between the water surface and the chiller) hv = velocity head delta (water resistance from the outlet ... generally about 0.5m~0.8m.) hf =...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.