Introduction
The document provides an overview of the FM Series cooling modules by Oriental Motor, designed to enhance equipment reliability and reduce maintenance costs by integrating fans with peripherals to prevent dust and water ingress.
Specifications
The FM Series includes models with IP55 and IP43 protection levels, suitable for environments requiring dust and water resistance. These modules feature a fan, filter, and cover, available in various sizes and configurations, including suction and exhaust types.
Installation and Maintenance
Installation is simplified through external screw tightening, and maintenance is facilitated by easy filter replacement. The design aims to improve equipment longevity by preventing dust and water ingress.
Cooling Methods
Two primary configurations are recommended: suction type at the bottom with a filter panel at the top, and suction type at the bottom with exhaust type at the top. These configurations help maintain internal pressure and prevent dust ingress.
Product Features
The FM Series offers modularity, easy installation, and maintenance. It includes a fan with a filter and cover, available in different sizes and airflow directions, supporting both AC and DC inputs.
Technical Specifications
Models vary in airflow and static pressure characteristics, depending on the degree of protection and hood size. IP55 models offer higher protection but lower airflow compared to IP43 models.
Product Line
The document lists various models with specific dimensions, power supply voltages, and fan configurations, catering to different application needs.
Filter Panels
Filter panels are designed to prevent dust and water droplets from entering enclosures. The document provides dimensions for filter media applicable to both IP55 and IP43 rated models, emphasizing regular maintenance to prevent clogging and ensure optimal cooling performance.
Accessories
Replacement filter media are available for both IP55 and IP43 models, with specific dimensions provided for each. Thermostats (AM1-WA1/AM1-XA1) are mentioned for energy conservation by activating fans only when necessary.
Recommendations
Regular checks of filter media for clogging are recommended to maintain cooling efficiency. The document suggests contacting technical support or visiting the Oriental Motor website for further details on specifications and characteristics.
See more

Catalog excerpts

Cooling Module-1

Cooling Fans Introduction MRS AC Input Variable Flow MRS Cooling Fans Centrifugal Blowers AC Input DC Input MF Cross Flow Fans AC Input DC Input FM Cooling Module Axial Flow Fans MU Cooling Module

 Open the catalog to page 1
Cooling Module-2

For details on this product please refer to our website, contact technical support or your nearest Oriental Motor sales office. www.orientalmotor.com Cooling Module FM Series The FM Series offers modular products that combine a fan with peripherals. These modules help reduce equipment problems caused by ingress of dust or water, while saving installation and replacement costs. ■ Features ● Preventing Ingress of Dust and Water Droplets The integrated structure consisting of a fan, filter and cover makes it easy to prevent ingress of dust and water droplets into the enclosure. ● Improvement of...

 Open the catalog to page 2
Cooling Module-3

Cooling Fans Introduction ■ Effective Cooling Using the FM Series "Fan and filter panel" and "filter panel" are available for the FM Series. By combining these panels as shown below, ingress of dust and water droplets into the enclosure can be prevented to achieve effective cooling. 2 □ Suction type "fan and filter panel" at the bottom, exhaust type "fan and filter panel" at the top Fan and Filter Panel Suction Type Axial Flow Fans Fan and Filter Panel Suction Type AC Input Variable Flow MRS Fan and Filter Panel Exhaust Type Filter Panel Thermostats AM1-WA1/ AM1-XA1 1 □ Suction type "fan and...

 Open the catalog to page 3
Cooling Module-4

Cooling Module ■ Types and Features Both IP55 and IP43 models are available. ● IP55/IP43 These models conform to the IP55 and IP43 under the IEC Standards. These models are ideal for applications where ingress of dust, foreign objects, water droplets, etc. must be prevented to ensure a high degree of protection. · Hood size: Large [209 mm×226 mm (8.23 in.×8.90 in.)], Medium [157 mm×170 mm (6.18 in.×6.69 in.)], Small [129 mm×134 mm (5.08 in.×5.28 in.)] · Installed fan: □119 mm − 38 mm (□4.69 in. − 1.50 in.) Thick AC Axial Flow Fan (Hood size: Large, Medium) □92 mm − 25 mm (□3.62 in. − 0.98 in.)...

 Open the catalog to page 4
Cooling Module-5

Cooling Fans Introduction ◇ Degree of Protection IP codes indicating the grade of dust-resistance and waterproofing are specified as follows under EN 60529. [Example] IP Code First Number IP4X IP5X Second Number First Number Protection against Contact or Ingress of Human Body Parts and Solid Objects Protection Level Test Condition Protected against ingress of wires etc. Solid objects with a diameter of 1.0 mm or more do not enter. Protected against powdery dust Powdery dust that may inhibit normal operation does not enter. Protection against Ingress of Water Protection Level Test Condition Sprayed...

 Open the catalog to page 5
Cooling Module-6

Cooling Module ■ Internal Structure of the FM Series The figure below illustrates the internal structure of the fan and filter panel. The fan, filter, cover and all other parts come pre-assembled. Finger Guard The nger guard protects ngers and other objects from coming in contact with the blades during operation. Filter Media The lter media shuts out dust, water droplets and other objects in the air to maintain clean air inside the enclosure. It is recommended that the lter media be checked periodically for clogging and replaced as necessary. Clogged lter media will cause the cooling capacity...

 Open the catalog to page 6
Cooling Module-7

Cooling Fans ● Fan and Filter Panel FM A 2 3 B I - 2 H 2 2 1 Series Cooling Method Power Supply Voltage Number of Installed Fans Module Dimensions (W×H×D [mm (in.)]) FM: FM Series Z: Filter Panel 2: Hood Type 3: Light Gray ■ Product Line Size ● IP43/Exhaust Type Power Supply Voltage VAC 157 mm × 170 mm (6.18 in. × 6.69 in.) Single-Phase 115 Installed Fan: □119 mm − 38 mm Thick Single-Phase 220/230 (□4.69 in. − 1.50 in. thick) 129 mm × 134 mm (5.08 in. × 5.28 in.) Single-Phase 115 Installed Fan: □92 mm − 25 mm Thick Single-Phase 220/230 (□3.62 in. − 0.98 in. thick) ● IP43/Suction Type Power Supply...

 Open the catalog to page 7
Cooling Module-8

Cooling Module Filter Panel Ingress of dust or water droplets into the enclosure and discharge dust from the enclosure can be prevented by installing a filter panel over the vent holes in the enclosure. ■ Product Line ● IP55 Model FMZ23CI-D FMZ23CI-E FMZ23CI-F The following items are included in each product. Filter Panel, Mounting Screws, Operating Manual ● Replacement Filter Media A thermostat makes it possible for fans to operate only when cooling is necessary, thereby conserving energy. ◇ Filter Media for IP55 Model FMXAC-D FMXAC-E FMXAC-F Applicable Model FM Series Dimensions 209 mm×226...

 Open the catalog to page 8

All ORIENTAL MOTOR catalogs and technical brochures

  1. Product Guide

    36  Pages

  2. Product Guide

    36  Pages

  3. DRS series

    2  Pages

  4. DGII

    2  Pages

  5. EH series

    12  Pages

  6. Servo Motors

    7  Pages

  7. DSC Series

    76  Pages

  8. Motors Torque

    6  Pages

  9. BLH Series

    36  Pages

  10. DSC Series

    11  Pages

  11. BXII Series

    31  Pages

  12. RKII Series

    51  Pages

  13. AZ Series

    10  Pages

  14. CVK Series

    24  Pages

  15. Stepper Motors

    33  Pages

  16. Servo motors

    9  Pages

  17. Stepping Motors

    23  Pages

  18. KII Series

    16  Pages

  19. RK Series

    4  Pages

  20. AS Series

    4  Pages

  21. AR Series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.