New 0.72° Stepper Motor and Driver Packages RK Series Built-in Controller (Stored Data) Type BEST PERFORMANCE & PRICE Pulse Input Type
Open the catalog to page 1Introducing a re-invented, affordable and high performance Stepper Motor and Driver Package. PERFORMANCE & PRICE
Open the catalog to page 2SAVE PRICE & ENERGY CONNECTION & SYSTEM PERFORMANCE & RELIABILITY New 0.72° Stepper Motor and Driver Packages
Open the catalog to page 3Reduction of total cost. PRICE & ENERGY Space Saving The RK Series offers significant improvements in motor performance, driver operation and functions compared to conventional products and is available at a new lower price. Slim and Compact This new driver was created by re-arranging the internal components and optimizing the usage of the space within the driver. The result, drivers can be installed side by side, reducing a significant amount of space. High-efficiency with Low Price New slim & compact driver Conventional Model RK Series Driver ●When drivers are installed in contact with each...
Open the catalog to page 4High Efciency Lower Heat Generation Reduces power consumption by up to 47% Continuous Operation is Achieved By optimizing the motor material, up to 47% of the power consumption has been reduced. This results in the reduced consumption of electricity and CO2 emission. By utilizing high-efficiency technology to reduce the motor heat, continuous operation is achieved. In addition, reduction of heat output means less reliance on cooling fans and heat sinks. ● Power Consumption Comparison ● Motor Surface Temperature Comparison under the Same Conditions [kWh/Year] Power consumption Operating Condition...
Open the catalog to page 5Easy to wire, easy to select. CONNECTION & SYSTEM Selection ● I/O Connector Wiring · No soldering · No crimping tools Easy Wiring · Wiring time reduction The new I/O connector does not require a screw and also eliminates the need for soldering or a special crimping tool. The motor connector can be connected easily by using a dedicated cable. This will reduce wiring time, maintenance and prevent mis-wiring. Easy Selection ● Free Motor Selection Service for Customers: I/O Signal Connectors Send us a motor selection inquiry via our website, fax or e-mail. ● Free Online Motor Sizing Tool Available...
Open the catalog to page 62 driver types available. Pulse Input Type Built-in Controller (Stored Data) Type ● Controlled by I/O Power CPU I/O Supply Module Module Module Pulse Input Type Built-in Controller Type Built-in Controller Type ● Controlled by serial communication Power CPU Serial Supply Module Module Module ● Controlled by Computer or Touch Screen Touch Screen Serial Communication Board ● Controlled by FA Network Power FA CPU Supply Network Module Module Module ③ FA Network CC-Link MECHATROLINKMECHATROLINKEtherCAT Network Converter Select the control method in accordance with your operating system. Set the operating...
Open the catalog to page 7Built-in Controller (Stored Data) Type CONNECTION & NETWORK Example of connection and control with the Built-in Controller (Stored Data) Type Using a Switch Box Since operating data is set in the driver, the motor can start and stop with hand switches. Easy control without the use of a PLC is possible. Simple Control Using PLC (No positioning control module is required) When using a PLC, you can built an operation system by connecting directly to an I/O Module. A positioning module is not necessary on the PLC side therefore space is saved and the system is simplified. Stepper Motor Unit Driver...
Open the catalog to page 8is a generic name of the products which support Factory Automation network control via I/O control, Modbus (RTU) control and network converter. Built-in Controller Type Modbus (RTU) control via PLC RS-485 communication can be used to set operating data, parameters and input operation commands. A maximum of 31 drivers can be connected to one serial module. There is also a group sending function for simultaneously starting multiple axes. The protocol supports Modbus (RTU), enabling connection with devices such as touch-screen panel computers and PCs. Simple Control Simple Wiring Serial Module CPU...
Open the catalog to page 9Performance and function to enhance reliability. PERFORMANCE & RELIABILITY High Accuracy High Torque High Efciency Highly Accurate Positioning Compact and High Torque Positioning accuracy of the RK Series is ±0.05° (±3 arc min). When the RK Series is used with a ball screw as shown in the drawing below, the stopping accuracy becomes ±0.0014 mm. The accuracy of the normal ground ball screw is ±0.01 mm, thus the accuracy is high enough for positioning operation. The RK Series is compact and produces high torque. The torque of the 42 mm (1.65 in.) frame size has increased 50%. This contributes to...
Open the catalog to page 10Protective Function Digitally Controlled Driver Step Angle can be Set Easily Built-in Alarm Features Utilizing a full-time microstepping driver controlled by a digital system improves the vibration characteristics of the 0.72° stepper motor. Current control is also done by a high specification digital CPU. This model uses PWM control instead of PAM control resulting in a sinusoidal wave form in each phase, significantly reducing vibration. For pulse input type, 32 step angles can be selected. To easily upgrade from a 1.8° stepper motor, use the step angle setting switch to match the existing...
Open the catalog to page 11Product Line ● List of Drivers and Motors Driver Type Motor Type Built-in Controller Type Standard Type Frame Size Electromagnetic Power Input Brake Single Phase 100-120 VAC Single Phase 200-240 VAC with Encoder✽ TS Geared Type (Spur Gear Mechanism) Single Phase 100-120 VAC Single Phase 200-240 VAC ✽We provide encoder installed model, but only for the built-in controller models. Permissible Torque, Maximum Torque [N∙m (lb-in)] · Basic model of the RK Series with Encoder · For encoder installed model, functions for monitoring positioning data, detecting positioning gap are available. · Resolution...
Open the catalog to page 12Features of the New Product Line NEW Standard Type with Encoder (Built-in controller type only) Encoder installed models make it possible to monitor the present position and detect for errors. ● Positioning Monitor This feature can be used to detect the position of the motor. For instance, to confirm normal operations, compare commanded position to the actual position. ● Return-to-Home Operation by ● Detecting for Errors The encoder will compare command position and encoder-count. If deviation exceeds the set value, a STEPOUT signal will be output. Positional errors due to rapid changes in load...
Open the catalog to page 1336 Pages
36 Pages
11 Pages
28 Pages
2 Pages
2 Pages
12 Pages
7 Pages
76 Pages
6 Pages
36 Pages
2 Pages
11 Pages
21 Pages
18 Pages
18 Pages
24 Pages
31 Pages
51 Pages
10 Pages
24 Pages
33 Pages
4 Pages
9 Pages
9 Pages
23 Pages
8 Pages
16 Pages
4 Pages
4 Pages
4 Pages
18 Pages
62 Pages
60 Pages
16 Pages
8 Pages
44 Pages
36 Pages
54 Pages