PLUG-IN CARDS OMR 700 INPUT CARDS OUTPUT CARDS POWER SUPPLY CARDS Outstanding Measurement Value
Open the catalog to page 1ORBIT MERRET, spol. s r.o. Vodňanská 675 / 30 198 00 Praha 9 Czech Republic Теlefon +420 281 040 200 Telefax +420 281 040 299 orbit@merret.eu www.orbit.merret.e
Open the catalog to page 2INPUT CARDS ANALOGUE 3x Universal input, isolated 4x Current / voltage input, isolated 4x Input for thermocouples J / K / T / E / B / S / R / N / L, isolated 2x Input for strain gauges with load cell bridge excitation, isolated 4x Precise current / voltage input, isolated 2x AC Current /voltage input, isolated 2x Input for LVDT sensors, isolated 1x 3fázové měření výkonu, izolovaný 8x Analogue / digital input 12x Input for counter /frequency 2x Input for UP / DW, IRC with sensor excitation, isolated OUTPUT CARD DIGITAL 4x Relay with switch-over contact 8x Relay with switch-on contact 2x...
Open the catalog to page 3IN.01 3x UNIVERSAL INPUT - ISOLATED UNIVERSAL INPUT CARD SETTINGS The following parameters are edited in the setting Select the Position of the card to be set. Use buttonsto scroll among the fitted cards. Floating floating arithmetic average of the number of measured values Exponential integration filter of the first order with a time constant measurement Filtr constant Data transfer priority of the selected card. Bigger number of plugged-in cards slows down data flow on the bus. It can be optimized by setting priorities. The real value of the data flow can be then controlled in diagnostics....
Open the catalog to page 4IN.01 TECHNICAL DATA TECHNICAL SPECIFICATION ±0,15 % of range (valid for 10 measur. / s) Overload capacity Digital filters Floating average, Exponential average Cold junction compensation (CJC) Range Connection* J (Fe-CuNi) K (NiCr-Ni) T (Cu-CuNi) E (NiCr-CuNi) B (PtRh30-PtRh6) S (PtRh10-Pt) R (Pt13Rh-Pt) N (Omegalloy) L (Fe-CuNi) POWER SUPPLY Power supply MECHANIC PROPERTIES Dimensions OPERATING CONDITIONS EN 61010-1, A2 2,5 kVAC over 1 min between bus and inputs 1 kVAC over 1 min between inputs Insulation resistance* for pollution degree II, measuring cat. III. Input / Bus - 300 V (PI),...
Open the catalog to page 5IN.02 4x CURRENT / VOLTAGE INPUT, ISOLATED DC CURRENT / VOLTAGE INPUT PM Rate < 320 measurements / s Accuracy 0,2 % of range CARD SETTINGS The following parameters are edited in the setting Select the Position of the card to be set. Use buttonsto scroll among the fitted cards. Filter selection Floating floating arithmetic average of the number of measured values Exponential integration filter of the first order with a time constant measurement Filtr constant Indicates the size of the filter value that corresponds to the minimum selected range of the input values Type of the card fitted in the...
Open the catalog to page 6IN.02 TECHNICAL DATA INPUTS TECHNICAL SPECIFICATION ±0,2 % of range (valid for 10 measur. / s) Overload capacity 10x (t < 100 ms), 2x Floating average, Exponential average reset after 500 ms Digital filters POWER SUPPLY Power supply MECHANIC PROPERTIES Dimensions OPERATING CONDITIONS Connection connector terminal board, cross section < 1,5 mm2 Working temperature Storage temperature Dielectric strength 2,5 kVAC over 1 min between bus and inputs 1 kVAC over 1 min between inputs Insulation resistance* for pollution degree II, measuring cat. III. Input / Bus - 300 V (PI), 150 (DI) Input / Input...
Open the catalog to page 7INPUT FOR RESISTIVE SENSORS Rate < 320 measurements / s Accuracy 0,2 % of range CARD SETTINGS The following parameters are edited in the setting Select the Position of the card to be set. Use buttonsto scroll among the fitted cards. Channel to be set. Use buttonsto scroll among the channels. Number of possible selectable channels is determined by the card, which is being set is used to navigate to the settings of the selected channel. Filter selection Floating floating arithmetic average of the number of measured values Exponential integration filter of the first order with a time...
Open the catalog to page 8IN.03 TECHNICAL DATA INPUTS TECHNICAL SPECIFICATION ±0,2 % of range (valid for 10 measur. / s) Overload capacity Digital filters Floating average, Exponential average Type Connection* POWER SUPPLY Power supply * In case of measurements with 2-wire connection it is necessary to connect the unused inputs (2d • E+ / S+, E- / S-). MECHANIC PROPERTIES Dimensions OPERATING CONDITIONS Connection connector terminal board, cross section < 1,5 mm2 Working temperature Storage temperature Dielectric strength 2,5 kVAC over 1 min between bus and inputs 1 kVAC over 1 min between inputs Insulation...
Open the catalog to page 9IN.04 4x INPUT FOR THERMOCOUPLES, ISOLATED Rate < 320 measurements / s Accuracy 0,2 % of range CARD SETTINGS The following parameters are edited in the setting Select the Position of the card to be set. Use buttonsto scroll among the fitted cards. Type of the card fitted in the specified position. Data transfer priority of the selected card. Bigger number of plugged-in cards slows down data flow on the bus. It can be optimized by setting priorities. The real value of the data flow can be then controlled in diagnostics. The maximum achievable data flow in slots A is 1100 frames/s, in slots B 550...
Open the catalog to page 10IN.04 TECHNICAL DATA INPUTS TECHNICAL SPECIFICATION J (Fe-CuNi)C K (NiCr-Ni) T (Cu-CuNi) E (NiCr-CuNi) B (PtRh30-PtRh6) S (PtRh10-Pt) R (Pt13Rh-Pt) N (Omegalloy) L (Fe-CuNi) ±0,2 % of range (valid for 10 measur./s) Overload capacity Digital filters Floating average, Exponential average Cold junction compensation (CJC) POWER SUPPLY Power supply MECHANIC PROPERTIES Dimensions OPERATING CONDITIONS Connection connector terminal board, cross section < 1,5 mm2 Working temperature Storage temperature Dielectric strength 2,5 kVAC over 1 min between bus and inputs 1 kVAC over 1 min between inputs...
Open the catalog to page 11INPUT FOR RESISTIVE SENSORS Rate < 320 measurements / s Accuracy 0,2 % of range CARD SETTINGS The following parameters are edited in the setting Select the Position of the card to be set. Use buttonsto scroll among the fitted cards. Channel to be set. Use buttonsto scroll among the channels. Number of possible selectable channels is determined by the card, which is being set is used to navigate to the settings of the selected channel. Filter selection Floating floating arithmetic average of the number of measured values Exponential integration filter of the first order with a time...
Open the catalog to page 12All Orbit Merret s.r.o. catalogs and technical brochures
-
OMT 1550
4 Pages
-
OMT 1450
4 Pages
-
MEASURING INSTRUMENTS
164 Pages
-
Paperless Recorder OMR 700
12 Pages
-
catalogueplc
12 Pages
-
OMX 312UNI
2 Pages
-
accessories20151
1 Pages
-
omp3820151
2 Pages
Archived catalogs
-
1x+ Series Calibrator
1 Pages
-
0X+ Calibrator
1 Pages