  3. PLUG-IN CARDS OMR 700

PLUG-IN CARDS OMR 700

PLUG-IN CARDS OMR 700
1 / 58 PagesView full catalog

PLUG-IN CARDS OMR 700

Product catalog summary
Specifications:
The document provides technical specifications for input cards in the OMR 700 system, detailing input types such as strain gauges, current/voltage inputs, and analogue/digital inputs. Each type has specific ranges, accuracy, and measurement rates.
Card Settings:
Settings involve selecting card position, type, and data transfer priority. Data flow optimization is possible by setting priorities, with maximum data flow rates specified for different slots.
Installation Procedures:
To install a new card, disconnect the recorder from power, remove the back cover, insert the card into the slot, and replace the cover before powering on the device.
Technical Data:
Each card type has specific technical data, including inputs, range, accuracy, overload capacity, power supply requirements, mechanical properties, and operating conditions.
Standards and Compliance:
The equipment complies with standards like EMC EN 61326-1 and IEC 980: 1993 for seismic resistance, and safety standards such as EN 61010-1.
Key Features:
Features include digital filters, watch-dog reset, calibration conditions, construction safety class, and IP rating.
Input for Counter/Frequency:
Supports various inputs with a frequency of less than 10 kHz, including features like input inversion and counter scaling.
3-Phase Wattmeter:
Measures voltage, current, power, frequency, harmonic distortion, phase shift, and power factor with specified ranges and accuracy.
Digital Outputs:
Includes relays with switch-over contact, supporting specific voltage and current limits, with features like hysteresis and relay inversion.
Output Modules:
Details several output modules with specific characteristics, including relays, open collector outputs, and SSR outputs.
Installation and Configuration:
Instructions for installing and configuring new cards, emphasizing power disconnection and proper slot insertion.
General Business Terms (GBT):
1. Introduction: Governs sale and purchase between ORBIT MERRET and partners.
2. Method of Contract Conclusion: Contracts are concluded through written orders.
3. Contract Conclusion: Concluded by order confirmation or contract signing.
4. Delivery of Goods: Delivery timelines and risk transfer details.
5. License: Non-exclusive software license granted.
6. Price and Payment Terms: Payment terms and penalties for late payment.
7. Duty of Quality Control and Defect Reporting: Guarantees and defect rectification methods.
8. Warranty: 60-month warranty with exclusions.
9. Termination of the Contract: Conditions for contract termination.
10. Final Provisions: Governed by Czech law, confidentiality requirements.
See more

Catalog excerpts

PLUG-IN CARDS OMR 700-1

PLUG-IN CARDS OMR 700 INPUT CARDS OUTPUT CARDS POWER SUPPLY CARDS Outstanding Measurement Value

 Open the catalog to page 1
PLUG-IN CARDS OMR 700-2

ORBIT MERRET, spol. s r.o. Vodňanská 675 / 30 198 00 Praha 9 Czech Republic Теlefon +420 281 040 200 Telefax +420 281 040 299 [email protected] www.orbit.merret.e

 Open the catalog to page 2
PLUG-IN CARDS OMR 700-3

INPUT CARDS ANALOGUE 3x Universal input, isolated 4x Current / voltage input, isolated 4x Input for thermocouples J / K / T / E / B / S / R / N / L, isolated 2x Input for strain gauges with load cell bridge excitation, isolated 4x Precise current / voltage input, isolated 2x AC Current /voltage input, isolated 2x Input for LVDT sensors, isolated 1x 3fázové měření výkonu, izolovaný 8x Analogue / digital input 12x Input for counter /frequency 2x Input for UP / DW, IRC with sensor excitation, isolated OUTPUT CARD DIGITAL 4x Relay with switch-over contact 8x Relay with switch-on contact 2x Analogue...

 Open the catalog to page 3
PLUG-IN CARDS OMR 700-4

IN.01 3x UNIVERSAL INPUT - ISOLATED UNIVERSAL INPUT CARD SETTINGS The following parameters are edited in the setting Select the Position of the card to be set. Use buttonsto scroll among the fitted cards. Floating floating arithmetic average of the number of measured values Exponential integration filter of the first order with a time constant measurement Filtr constant Data transfer priority of the selected card. Bigger number of plugged-in cards slows down data flow on the bus. It can be optimized by setting priorities. The real value of the data flow can be then controlled in diagnostics. The...

 Open the catalog to page 4
PLUG-IN CARDS OMR 700-5

IN.01 TECHNICAL DATA TECHNICAL SPECIFICATION ±0,15 % of range (valid for 10 measur. / s) Overload capacity Digital filters Floating average, Exponential average Cold junction compensation (CJC) Range Connection* J (Fe-CuNi) K (NiCr-Ni) T (Cu-CuNi) E (NiCr-CuNi) B (PtRh30-PtRh6) S (PtRh10-Pt) R (Pt13Rh-Pt) N (Omegalloy) L (Fe-CuNi) POWER SUPPLY Power supply MECHANIC PROPERTIES Dimensions OPERATING CONDITIONS EN 61010-1, A2 2,5 kVAC over 1 min between bus and inputs 1 kVAC over 1 min between inputs Insulation resistance* for pollution degree II, measuring cat. III. Input / Bus - 300 V (PI), 150...

 Open the catalog to page 5
PLUG-IN CARDS OMR 700-6

IN.02 4x CURRENT / VOLTAGE INPUT, ISOLATED DC CURRENT / VOLTAGE INPUT PM Rate < 320 measurements / s Accuracy 0,2 % of range CARD SETTINGS The following parameters are edited in the setting Select the Position of the card to be set. Use buttonsto scroll among the fitted cards. Filter selection Floating floating arithmetic average of the number of measured values Exponential integration filter of the first order with a time constant measurement Filtr constant Indicates the size of the filter value that corresponds to the minimum selected range of the input values Type of the card fitted in the specified...

 Open the catalog to page 6
PLUG-IN CARDS OMR 700-7

IN.02 TECHNICAL DATA INPUTS TECHNICAL SPECIFICATION ±0,2 % of range (valid for 10 measur. / s) Overload capacity 10x (t < 100 ms), 2x Floating average, Exponential average reset after 500 ms Digital filters POWER SUPPLY Power supply MECHANIC PROPERTIES Dimensions OPERATING CONDITIONS Connection connector terminal board, cross section < 1,5 mm2 Working temperature Storage temperature Dielectric strength 2,5 kVAC over 1 min between bus and inputs 1 kVAC over 1 min between inputs Insulation resistance* for pollution degree II, measuring cat. III. Input / Bus - 300 V (PI), 150 (DI) Input / Input -...

 Open the catalog to page 7
PLUG-IN CARDS OMR 700-8

INPUT FOR RESISTIVE SENSORS Rate < 320 measurements / s Accuracy 0,2 % of range CARD SETTINGS The following parameters are edited in the setting Select the Position of the card to be set. Use buttonsto scroll among the fitted cards. Channel to be set. Use buttonsto scroll among the channels. Number of possible selectable channels is determined by the card, which is being set is used to navigate to the settings of the selected channel. Filter selection Floating floating arithmetic average of the number of measured values Exponential integration filter of the first order with a time constant...

 Open the catalog to page 8
PLUG-IN CARDS OMR 700-9

IN.03 TECHNICAL DATA INPUTS TECHNICAL SPECIFICATION ±0,2 % of range (valid for 10 measur. / s) Overload capacity Digital filters Floating average, Exponential average Type Connection* POWER SUPPLY Power supply * In case of measurements with 2-wire connection it is necessary to connect the unused inputs (2d • E+ / S+, E- / S-). MECHANIC PROPERTIES Dimensions OPERATING CONDITIONS Connection connector terminal board, cross section < 1,5 mm2 Working temperature Storage temperature Dielectric strength 2,5 kVAC over 1 min between bus and inputs 1 kVAC over 1 min between inputs Insulation resistance*...

 Open the catalog to page 9
PLUG-IN CARDS OMR 700-10

IN.04 4x INPUT FOR THERMOCOUPLES, ISOLATED Rate < 320 measurements / s Accuracy 0,2 % of range CARD SETTINGS The following parameters are edited in the setting Select the Position of the card to be set. Use buttonsto scroll among the fitted cards. Type of the card fitted in the specified position. Data transfer priority of the selected card. Bigger number of plugged-in cards slows down data flow on the bus. It can be optimized by setting priorities. The real value of the data flow can be then controlled in diagnostics. The maximum achievable data flow in slots A is 1100 frames/s, in slots B 550 frames...

 Open the catalog to page 10
PLUG-IN CARDS OMR 700-11

IN.04 TECHNICAL DATA INPUTS TECHNICAL SPECIFICATION J (Fe-CuNi)C K (NiCr-Ni) T (Cu-CuNi) E (NiCr-CuNi) B (PtRh30-PtRh6) S (PtRh10-Pt) R (Pt13Rh-Pt) N (Omegalloy) L (Fe-CuNi) ±0,2 % of range (valid for 10 measur./s) Overload capacity Digital filters Floating average, Exponential average Cold junction compensation (CJC) POWER SUPPLY Power supply MECHANIC PROPERTIES Dimensions OPERATING CONDITIONS Connection connector terminal board, cross section < 1,5 mm2 Working temperature Storage temperature Dielectric strength 2,5 kVAC over 1 min between bus and inputs 1 kVAC over 1 min between inputs Insulation...

 Open the catalog to page 11
PLUG-IN CARDS OMR 700-12

INPUT FOR RESISTIVE SENSORS Rate < 320 measurements / s Accuracy 0,2 % of range CARD SETTINGS The following parameters are edited in the setting Select the Position of the card to be set. Use buttonsto scroll among the fitted cards. Channel to be set. Use buttonsto scroll among the channels. Number of possible selectable channels is determined by the card, which is being set is used to navigate to the settings of the selected channel. Filter selection Floating floating arithmetic average of the number of measured values Exponential integration filter of the first order with a time constant...

 Open the catalog to page 12