OMR 700 PAPERLESS RECORDER OMR 700 Modular data recorder with 8 slots for plug-in cards • analogue inputs, max. 12 inputs/module • digital inputs, max. 12 inputs/module • analogue outputs, max. 4 outputs/module • digital outputs, max. 10 outputs/module • data outputs Basic features of the recorder • color TFT display 5,7“ with a capacitive panel • primary and backup system • digital inputs and outputs • record into internal memory, SD card or USB Flash • Ethernet 10/100B, RS 485 – Modbus • USB, microUSB • internal data memory 2x 512 MB • built-in speaker • RTC • size 150 x 150 mm • protection...
Open the catalog to page 2DATA RECORDING The OMR 700 can record measured data from any of its active inputs, nodes and mathematical functions. Data are stored in the internal 512 MB memory with compression that allows up to four-fold increase of its physical memory without slowing down. Data can also be stored on an external SD card or USB flash drive. In case of a limited number of measuring inputs, measured data can be stored with a period of up to 1 ms. The records can be either in BIN or „CVS“ format. However, the latter is much more demanding on memory space. Recording speed according to number of channels / memory...
Open the catalog to page 3Under the hinged lid, which can be opened by a light pressure two blue locks, there is access to control push buttons, microUSB for recorder setting via PC, SD card slot, and USB Flash drive connector. In the bottom right corner you will find a Stylus for easier control of the recorder and for display drawings. Cover of the lid is IP64 so that your recorder, SD card, and USB Flash drive will always stay dry.. RECORDING OF EVENTS GROUP A Change setting - User 1 Heat - [email protected]
Open the catalog to page 4DATA CONNECTION FTP server VNC server WEB server REC In its basic version the recorder is equipped with Ethernet 10/100Base connection and it offers: • display projection • transfer of stored data (internal memory, SD card, USB Flash) • recording of events Other network functions are: • sending e-mail* • time synchronization • DHCP, TCP/IP Modbus (client) MODBUS RTU/MODBUS over TCP Master REC The second version, offering use of RS485 with a MODBUS RTU protocol • up to 247 devices can be connected to the bus Sensors Slave The equipment can be used for: • sensors connection • projecting measured...
Open the catalog to page 5HTTP/FTP/MODBUS over TCP/emal DC Standard equipment 4x input for thermocouples, isolated J/K/T/E/B/S/R/N/L with cold junction compensation 2x input for strain gauges, isolated range: 1…2/8/16 mV/V with sensor power supply 2x AC/PWR input, isolated 0…450 V/0…5 A voltage, current, power, frequency 8x digital input 12…250 V AC/DC 12x counter/frequency < 10 kHz 2x UP/DW counter/frequency/IRC < 1 MHz 4x input for Pt/Ni/Cu xxxx, isolated 2- and 3-wire connection 5x input for Pt/Ni/Cu xxxx 2- and 3-wire connection Under the hinged cover are accessible
Open the catalog to page 6RS 485 Standard equipment Relays OUT.1 4x Relay with a switch-over contact OUT.2 8x Relay with a switch-on contact OUT.3 8x open collector, NPN OUT.4 16x open collector, NPN with common terminal OUT.5 8x open collector, PNP 2x Analogue output, isolated 4x Analogue output, isolated the following elements and the Stylus menu record reset Stylus Recorder can hold up to 8 cards in any combination
Open the catalog to page 7OMR 700 CONNECTION – INPUT IN.1 3x Universal input F IN.8 2x input for strain gauges
Open the catalog to page 8IN.13 2x Fast pulse input IN.14 2x input for LVDT sensors CONNECTION – OUTPUT OUT.1 4x Relay, switch-over contact OUT.2 8x Relay, switch-on contact DGND: reference potential for data and +5 V A: RxD/TxD-N data reception/transmission, negative Analog output - voltage CNTR: signal for repeater control B: RxD/TxD-P data reception/transmission, positive Analog output - current
Open the catalog to page 9OMR 700 TECHNICAL DATA PROJECTION Display: 5,7“color TFT display with capacitive touch screen Brightness: adjustable COMMUNICATION Protocols: ASCII, MODBUS RTU, FTP, SMPT Data format: 8 bits + without parity + 1 stop bit (ASCII) Rate: 300…230 400 Baud RS 485: isolated, addressing (max. 31 instrum.), Modbus RTU (Master) Ethernet: 10/100 BaseT, secure communication, SMPT, FTP, TCP/IP Modbus (Slave) Wi-Fi: optional module with standard or industrial temperature range INSTRUMENT FUNCTIONS TC: 25 ppm/°C Accuracy: depending on the measuring card used Rate: depending on the measuring card used Accuracy...
Open the catalog to page 10Power supply 10...30 V AC/DC, isolated 80…250 V AC/DC, isolated no yes, 0°…50°C yes, -20°…60°C Wi-Fi modul Features, see table „Card types“ Zde uveďte seznam vybraných karet CARD TYPES Order code Transmitter (resolution) Rate (meas./s) Isolated channels Power supply Power supply 2x input for strain gauges with excitation 3x precise power/voltage input 2x voltage (VRMS), current (ARMS), frequency (Hz), power P, Q, S, cos fi 0…30 V, PNP/NPN/contact, adjustable comparation levels, input frequency 0,1 Hz…10 kHz 5/24 V, TTL/Line, adjustable comparation levels, input frequency 0,1 Hz…1 MHz 2x input...
Open the catalog to page 11ORBIT MERRET, spol. s r. o. Vodňanská 675/30 198 00 Praha 9 Czech Republic tel.: +420 281 040 200 fax.: +420 281 040 299 e-mail: [email protected] www.orbit.merret.eu ORBIT MERRET, spol. s r. o. represents in the Czech Republic and in Slovakia the companies