OMX 312UNI

OMX 312UNI

OMX 312UNI

Product catalog summary
Overview: The document provides technical specifications and operational details for the OMX 312UNI, a digital DIN rail mounted signal converter by Orbit Merret. It is designed for high accuracy and stability, featuring a microprocessor with a 24-bit ∆∑ A/D converter.
Programmable Input: The device allows selection of input type and measuring range. It supports standard, teach-in, and manual settings for assigning input values to analog output values.
Analog Output: The outputs are isolated and configurable with a resolution of 10,000 parts. Available ranges include 0-10 V, 0-20 mA, and 4-20 mA.
Excitation: Provides a fixed 24 VDC/35 mA isolated power supply.
Functions: Includes linearization for non-linear signals, tare function, simulation mode, and various math functions such as polynomial and logarithmic calculations.
Digital Filters: Offers floating, exponential, and arithmetic averaging for digital filtering.
Operation: Configuration can be done via DIP switches or PC using OM Link software. Settings are stored in EEPROM memory.
Technical Data: The device supports multiple input types including DC, PM, RTD, T/C, and DU. It features galvanic isolation and can be used as a signal splitter.
Instrument Accuracy: High accuracy with a rate of 1-100 measurements per second and overload capacity of 2x; 10x (t < 30 ms).
Mechanical Properties: Made from incombustible PA 66 material, the device is compact and designed for DIN rail installation.
Operating Conditions: Suitable for temperatures between -20°C and 60°C, with IP20 protection and compliance with various safety and EMC standards.
See more

Catalog excerpts

OMX 312UNI-1

DIGITAL ISOLATED CONVERTER mA OPERATION The device can be configured either by DIP switches located on the side of the housing or by PC using the OM Link SW. The same SW can be used to edit and archive all device settings, as well as to perform firmware updates and customer calibration. A standard microUSB cable is required for PC to device connection. Tech-in process can be performed for the measuring range currently selected using the front panel buttons. All settings are stored in the EEPROM memory (preserved even after power-off) Multifunction input (DC, PM, RTD, T/C, DU) 2x Analogue outputs, passive/active Quick conguration by DIP switch PC congurable via USB port Excitation 24 VDC Galvanic isolation 2.5 kVAC Simple instalation to DIN rail Power supply 10…30VDC, 24 VAC The OMX 300 model series are digital DIN rail mounted signal converters housed in an enclosure only 17.5 mm wide. The OMX 312UNI type is a galvanic isolated single-channel universal signal converter / splitter. It can be congured for 10 different input variants. Setting of both the input and output ranges can be done conveniently by a DIP switch located on the side of the housing or from a PC via the OM Link SW. You can also use this converter as a splitter into 2 analogue outputs. This device is based on a microprocessor with a 24-bit ∆∑ A/D converter, which guarantees high accuracy and excellent stability. STANDARD FUNCTIONS* PROGRAMMABLE INPUT Selection: of input type and measuring range Standard setting: any input values can be assigned to Min and Max values of the analog output Teach-in: any input values can be assigned to Min and Max values of the actual (unknown) input signal Manual setting: the known Min and Max values of the input signal can be set manually and any analog output values can be assigned to each of them at the same time ANALOG OUTPUT Type: isolated, congurable with resolution of 10 000 parts, rate < 3.5 ms Range: 0…10 V, 0…20 mA,4…20 mA EXCITATION Range: 24 VDC/35 mA, isolated FUNCTIONS Linearization: 100-point conversion of non-linear input signals by interpolation Tare: designed to reset display upon non-zero input signal Simulation: test mode in which range, value and duration of the step can be set Math functions: polynomial, inverse polynomial, logarithm, exponential, power, root DIGITAL FILTERS Floating average: from 2...30 measurements Exponential average: from 2...100 measurements Arithmetic average: from 2...100 measurements * this setting is only possible via the OM Link SW

 Open the catalog to page 1
OMX 312UNI-2

TECHNICAL DATA INPUT J (Fe-CuNi) K (NiCr-Ni) T (Cu-CuNi) E (NiCr-CuNi) B (PtRh30-PtRh6) S (PtRh10-Pt) R (Pt13Rh-Pt) N (Omegalloy) L (Fe-CuNi) XK (Chromel-Copel) 1 The range is selectable either by DIP switch or by OM Link free SW from PC Input 3 Input 3 Input 3 Input 1 Input 1 Input 1 Input 1 Input 1 Input 1 Input 2 Input 2 Input 2 Cu 50/100, 4 260 ppm/°C Cu 50/100, 4 280 ppm/°C 2-, 3- or 4-wire, with broken cable/sensor detection Connection: connector terminal blocks, section < 2.5 mm2 Stabilization period: within 5 minutes after switch-on Working temperature: -20°…60°C Storage temperature:...