1. Catalogs
  2. Optron
  3. power controller for medium wave, nonventilated IR-modules

power controller for medium wave, nonventilated IR-modules

power controller for medium wave, nonventilated IR-modules

Product catalog summary
Overview: The document provides technical specifications and features of the ILS3-10 M power controller designed for mediumwave, non-ventilated infrared (IR) modules. It highlights the controller's capabilities, construction, and compliance with industry standards.
Specifications:
  • Output Power: Maximum of 10 kW (3 x 16 A).
  • Working Principle: Utilizes pulse group control for power management.
  • Output Adjustment Range: 0 to 100% adjustable via a front-sided scale potentiometer or an external 0-10 V DC signal.
  • Mains Connection: Equipped with a 2 m connecting cable and a 16 A CEE plug, requiring 3 phases (3x 400 V + N + PE, 50/60 Hz).
  • Consumer Connection: Internal terminal connection with three cable glands for up to three consumers (3 x 230 V or 3 x 400 V, 50/60 Hz).
  • Casing: Made of aluminum, lacquered in RAL7035 light grey with an anodized front plate.
  • Protection Class: IP 20.
  • Dimensions: 260 x 145 x 345 mm.
  • Weight: Approximately 5 kg.
  • Item Number: 131921.
Features:
  • Stepless and lossless control certified by VDE and CE.
  • Noise suppression class A suitable for industrial sectors, compliant with IEC 60947-4-3 and IEC 61000-4-2 standards.
  • Includes a ventilated heat sink on the back and a mains switch on the front.
Additional Information: The pulse group control method offers a cost-effective alternative to phase angle control, minimizing the flicker effect due to the inertia of connected IR-modules.
See more

Catalog excerpts

power controller for medium wave, nonventilated IR-modules-1

Power controller For mediumwave, nonventilated IR-modules Stepless and lossless controls, VDE and CE certified The pulse group control is assembled for the power controlling of the mediumwave IR-modules. This principle allows a simple construction and is therefore a low-cost alternative to a phase angle contol. Through the inertia of the connected IR-modules the often annoying flimmer effect is nearly eliminated. Type ILS3-10 M Output power: Working principle: Output adjustment range: Mains connection: Consumer connection: Casing: Protection class: Other features: Dimensions ( W x H x D): Weight: Item number: ILS3-10 M max. 10 kW (max. 3 x 16 A) pulse group control 0 … 100% by front-sided scale potentiometer or external 0 ... 10 V DC signal (switchable by terminal connections) 2 m connecting cable with 16 A CEE plug; 3x 400 V + N + PE (50/60 Hz) Attention: 3 phases needed internal terminal connection (3 cable glands on the back for max. 3 consumer); 3 x 230 V or 3 x 400 V (50/60 Hz) aluminum lacquered (RAL7035 light grey), aluminum anodised (frontplate) IP 20 noise suppression class A for industrial sectors IEC 60947-4-3, IEC 61000-4-2; ventilated heat sink on the back; mains switch front-sided 260 x 145 x 345 mm approx. 5 kg 131921 All prices excl. VAT – July 2016 Documentation last updated: 11.05.2016 OPTRON GMBH • Steinriede 12 • D-30827 Garbsen / Hannover • Germany Phone: +49 (0)5131 7083 - 0 • Fax.: +49 (0)5131 7083 - 25 www.optron-gmbh.de • e-mail: mail@opt

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.