video corpo

optris CTlaser G5

optris CTlaser G5

optris CTlaser G5

Product catalog summary
Overview: The optris® CTlaser G5 is an infrared thermometer designed for precise temperature measurements on various types of glass, including flat glass, container glass, light bulbs, car glass, and solar panels. It features a temperature range from 100 °C to 1650 °C and utilizes a double laser visor for accurate measurement field marking.
Key Features:
  • Temperature measurement range: 100 °C to 1650 °C.
  • Measurement fields starting from 1.0 mm with an exposure time of 10 ms.
  • Compact sensing head suitable for ambient temperatures up to 85 °C without additional cooling.
  • Optional cooling and protection accessories for harsh environments.
Measurement Specifications:
  • Adjustable temperature ranges: 100 °C to 1200 °C (G5L), 250 °C to 1650 °C (G5H), 200 °C to 1650 °C (G5HF).
  • Spectral range: 5.0 μm.
  • Optical resolution: 45:1 or 70:1 depending on the model.
  • System accuracy: ±1% or ±1.5 °C.
  • Repeatability: ±0.5% or ±0.5 °C.
  • Temperature resolution: 0.1 K.
  • Signal processing includes peak hold, valley hold, and average functions.
General Specifications:
  • Environmental rating: IP 65 (NEMA-4).
  • Operating ambient temperature: -20 °C to 85 °C.
  • Storage temperature: -40 °C to 85 °C.
  • Relative humidity: 10 – 95%, non-condensing.
  • Vibration and shock resistance: 3 G and 50 G respectively.
Electrical Specifications:
  • Outputs: Analog (0/4 – 20 mA, 0 – 5/10 V, thermocouple J, K) and digital (USB, RS232, RS485, CAN, Profibus DP, Ethernet).
  • Power supply: 8 – 36 V DC with a maximum current draw of 160 mA.
  • Laser specifications: 635 nm, 1 mW, controllable via electronic box or software.
Optical Specifications:
  • Adjustable mounting angle in two axes.
  • Additional optics available for different measurement distances.
Accessories: Options include water cooling, air purge collars, and mounting devices for cooling housing.
See more

Catalog excerpts

optris CTlaser G5-1

optris® CTlaser G5 TECHNICAL DATA Infrared thermometer with laser visor for temperature measurements on glass from 100 °C to 1650 °C Features: • recise temperature measurements on glat glass, container glass, light bulbs, car P glass and solar pannels • emperature ranges from 100 °C to 1650 °C, measurement fields from 1.0 mm T and exposure time 10 ms • Innovative double laser visor for exact marking of measuring field • Compact size of sensing head • Suitable for ambient temperatures of up to 85 °C without additional cooling • Cooling and protection accessories for rugged environments Measurement specifications Temperature range (adjustable via programming keys or software) Spectral range General specifications Environmental rating Optical resolution (90 % energy) –20 °C ... 85 °C (sensing head, 50 °C with laser ON) –20 °C ... 85 °C (electronics) System accuracy2) (at ambient temp. 23 ±5 °C) Storage temperature – 40 °C ... 85 °C (sensing head) – 40 °C ... 85 °C (electronics) Repeatibility (at ambient temp. 23 ±5 °C) Relative humidity Temperature resolution 600 g (sensing head) / 420 g (electronics) Emissivity / Gain (adjustable via programming keys or software) Transmissivity (adjustable via programming keys or software) Signal processing (parameter adjustable via programming keys or software, respectively) Peak hold, valley hold, average; extended hold function with threshold and hysteresis optris® Compact Connect Electrical specifications Outputs / analog Output / alarm Relay: 2 x 60 V DC/ 42 V ACeff; 0.4 A; optically isolated USB, RS232, RS485, CAN, Profibus DP, Ethernet (optional) Output impedances mA max. 500 Ω (bei 5 – 36 V DC) mV min. 100 kΩ load impedance thermocouple 20 Ω Programmable functional inputs for external emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions) Cable length Power supply Current draw 1 mW, ON/OFF via electronic box or software The functioning of the LCD display may be limited in ambient temperatures below 0 °C 2) ε = 1, response time 1 s 3) Whichever is greater 4) With dynamic adaptation at low signal levels 1) Optris GmbH · Ferdinand-Buisson-Str.

 Open the catalog to page 1
optris CTlaser G5-2

Optical specifications Additional optics, D:S = 45:1 Dimension Electronics Accessories (examples) Mounting angle, adjustable in two axes (ACCTLAB) Water cooling and air purge collar for sensing head (ACCTLW + ACCTLAP) Mounting device for cooling housing (ACCTLRM) Specifications are subject to change without further notice · CTlaser G5-EN2018-08-A Sensing head

 Open the catalog to page 2

All Optris GmbH & Co. KG catalogs and technical brochures

  1. Infrared Basics

    21  Pages

  2. optris Xi 80

    2  Pages

  3. optris Xi 410

    2  Pages

  4. optris CT 4M

    2  Pages

  5. optris PI 05M

    2  Pages

  6. CSmicro 2M

    2  Pages

  7. optris PI 1M

    2  Pages

  8. optris CT 3M

    2  Pages

  9. optris CT G5

    2  Pages

  10. optris CTfast

    2  Pages

  11. CX hs

    2  Pages

  12. IR-Basics

    40  Pages

  13. PI NetBox

    1  Page

  14. CTlaser P7

    2  Pages

  15. CSlaser G5HF

    2  Pages

  16. CSlaser 2M

    2  Pages

  17. Optris CT P7

    2  Pages

  18. optris CT P3

    2  Pages

  19. optris-CT G5

    2  Pages

  20. CT 3M

    2  Pages

  21. CT 1M 2M

    2  Pages

  22. CThot LT

    2  Pages

  23. CTfast LT

    2  Pages

  24. CT LT

    2  Pages

Archived catalogs

  1. CSmed LT

    2  Pages

  2. optris CX LT

    2  Pages

  3. optris MS LT

    2  Pages

  4. optris CX

    2  Pages

  5. PI 450 G7

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.