Precise non-contact temperature measurement of liquid metals from 1000 °C to 2000 °C Features: • Precise temperature measurement of molten metal • Decrease of measurement errors at emissivity changes or wrong settings thanks to short wavelength of 525 nm • Temperature range from 1000 °C to 2000 °C, measuring fields from 1 mm and exposure times from 1 ms • Suited for ambient temperatures of 85 °C without additional cooling, laser switches of automatically at 50 °C • Optical resolution 150:1, focus settings scalable • Double laser visor with 2 laser beams for exact measuring field marking and focussing Measurement specifications General specifications Environmental rating Ambient temperature11 Storage temperature Relative humidity Vibration (sensor) Shock (sensor) Weight Electrical specifications Outputs / analog Alarm output Optional Outputs / digital Output impedances Inputs Cable length Power Supply Current draw Laser 635 nm IP 65 (NEMA-4) -20 °C ... 85 °C (sensing head, 50 °C with laser ON) -20 °C ... 85 °C (electronics) -40 °C ... 85 °C (sensing head) -40 °C ... 85 °C (electronics) 10 - 95 %, non-condensing IEC 68-2-6: 3 G, 11 - 200 Hz, any axis IEC 68-2-27: 50 G, 11 ms, any axis 600 g (sensing head) / 420 g (electronics) 0/4 - 20 mA, 0 - 5/ 10 V, thermocouple J, K 24 V / 50 mA (open collector) Relay: 2 x 60 V DC/ 42 V ACeff; 0.4 A; optically isolated USB, RS232, RS485, CAN, Prolibus DP, Ethernet (optional) mA max. 500 Q (with 8 - 36 V DC) mV min. 100 kQ load impedance thermocouple 20 Q Programmable functional inputs lor external emissivity adjustment, ambient temperature compensation, trigger (reset ol hold functions) 3 m (standard), 8 m, 15 m 8 - 36 V DC max. 160 mA 1 mW, ON/OFF via electronic box or software Temperature range (scalable via programming keys or soltware) Spectral range Optical resolution (90 % energy) System accuracy21 (at ambient temp. 23 ±5 °C) Repeatability (at ambient temp. 23 ±5 °C) Temperature resolution Exposure time3) Emissivity/ Gain (adjustable via programming keys or soltware) Transmissivity/ Gain (adjustable via programming keys or soltware) Signal processing (parameter adjustable via programming keys or soltware, respectively) Software Peak hold, valley hold, average; extended hold lunction with threshold and hysteresis optris® Compact Connect 1 The functioning of the LCD display may be limited in ambient temperatures below 0 °C 2) e = 1, Exposure time 1 s 3) With dynamic adaptation at low signal levels Optris GmbH ■ Ferdinand-Buisson-Str. 14 ■ 13127 Berlin ■ Germany Phone: +49 (0)30 500 197-0 ■ Fax: +49 (0)30 500 197-10 ■ E-mail: [email protected] ■ www.optris.gl
Open the catalog to page 1Sensing head Accessories (examples) Mounting angle, adjustable in two axes (ACCTLAB) Cooling housing (ACCJCTL) Mounting angle for cooling housing, adjustable in two axes (ACCJAB) Water cooling and air purge for sensing head (ACCTLW + ACCTLAP) Mounting device for cooling housing (ACCTLRM) Specifications are subject to change without notice ■ CTlaser 05M-EN2018-08-A
Open the catalog to page 232 Pages
2 Pages
21 Pages
17 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
12 Pages
8 Pages
4 Pages
40 Pages
2 Pages
1 Page
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages