video corpo

optris CTex LT

optris CTex LT

optris CTex LT

Product catalog summary
Overview: The optris® CTex LT is a two-piece measuring system designed for use in hazardous areas. It consists of an active electronic evaluation unit and a passive IR receiver (sensing head). The system is designed to be intrinsically safe with energy limitation provided by zener barriers.
Features:
  • Two-piece system with active electronics and passive IR receiver.
  • CTex sensing head can be installed in hazardous areas as a passive element.
  • Energy limitation through zener barriers approved for zone 1 (PTB 01 ATEX 2053/ E II (1/2) GD [EEx ia/ib] IIC/IIB).
Concept and Scope of Delivery:
  • Classified as a simple electrical device according to EN 60079-0/ EN 60079-11.
  • Intrinsically safe with two double zener barriers (type 9002/22-032-300-111 by R. STAHL AG).
  • Includes CTLT sensor with selectable optics (2:1, 15:1, 22:1) and cable lengths (3 m, 8 m, 15 m).
  • Aluminum housing with mounting for zener barriers and CT electronics.
Technical Data (Zener Barriers):
  • Approvals for Europe (CENELEC), USA, and Canada.
  • Explosion protection for various zones and classes.
  • Environmental rating: IEC 60529, IP 20 for clamping carrier, IP 40 for housing.
  • Ambient temperature range: –20 °C to 60 °C.
Electrical Specifications:
  • Inductance for sensor cable: 0.55 mH/km to 0.56 mH/km.
  • Capacitance for sensor cable: 16.5 nF/km to 17.9 nF/km lead/lead, 101.0 nF/km to 103.4 nF/km lead/rest.
  • Capacitance in sensing head: Ceramic SMD Capacitors 6.8 nF ± 20%.
Connections and Dimensions:
  • Connections include TP+, TP-, PT1000, and shielded cable type FEP TD 833 CF, max. 15 m.
  • Mounting rail and aluminum housing (CA-215) for installation.
See more

Catalog excerpts

optris CTex LT-1

optris® CTex LT TECHNICAL DATA optris® CT for applications in hazardous areas -^optrisI 1infrared measurements Features: • Two-piece measuring system with active electronic for evaluation and passive IR receiver (sensing head) • CTex sensing head can be installed as passive element in hazardous areas • Energy limitation with appropriate zener barriers (STAHL) with approval for zone 1 \ (PTB 01 ATEX 2053/ E II (1/2) GD [EEx ia/ib] IIC/IIB) Concept / Scope of delivery Technical data (zener barriers)1 Explosion protection Europe (CENELEC): for zone 1: PTB 01 ATEX 2053X for zone 2: PTB 01 ATEX 2054X IECEx PTB 08.0057X USA: ULE81680V1S3 Canada: CSA 1284580 (LR 43394) Europe (CENELEC): for zone 1: E II (1/2) GD [EEx ia/ib] IIC/IIB for zone 2: E II 3 GD EEx nA II T4 Classification of the optris® CT sensing heads according to EN 60079-0/ EN 60079-11 (category of simple electrical devices)21 Intrinsically safe by limitation of the energy with two double zener barriers, type 9002/22-032-300-111 (R. STAHL AG) CTLT - Sensor (optics 2:1, 15:1,22:1) with cable length 3 m, 8 m or 15 m (selectable) Aluminum housing with mounting appliance for two zener barriers and CT electronics 2 zener barriers, type 9002/22-032-300-111 (R. STAHL AG)3) 1 Declaration of company R. Stahl AG 2 Verification by the operator 3) NOTE: The functionality and correct reading of the CT sensor can only be guaranteed if the recommended barriers are used Installation Environmental rating I.S. circuits for: class I, II, III, division 1, groups A, B, C, D, E, F, G I.S. circuits for: class I, zone 0, group IIC class I, division 2, groups A, B, C, D class I, zone 2, group IIC Canada: I.S. circuits for: class I, groups A, B, C, D; class II, groups E, F, G class III class I, division 2, groups A, B, C, D class I, zone 2, groups IIC in zone 2, division 2 and in safe area acc. to IEC 60529/ clamping carrier IP 20/ housing IP 40 Ambient temperature Optris GmbH ■ Ferdinand-Buisson-Str. 14 ■ 13127 Berlin ■ Germany Phone: +49 (0)30 500 197-0 ■ Fax: +49 (0)30 500 197-10 ■ E-mail: [email protected] ■ www.optris.global

 Open the catalog to page 1
optris CTex LT-2

Manufacturer’s declaration for the CTex measurement system To verify that the optris CT sensing head is a simple electrical device according to EN 60079-11 item 5.7 we hereby confirm the following technical data: • nductance (available for the sensor cable only): I Inductance of the loops min. 0.55 mH/ km max. 0.56 mH/ km • n relation to a cable length of 15 m: I Inductance of the loops min. 0.825 *10–3 mH max. 0.84 *10–3 mH • Capacitance: Capacitance of the sensor cable: Capacitance lead / lead min. 16.5 nF/ km max. 17.9 nF/ km Capacitance lead / rest min. 101.0 nF/ km max. 103.4 nF/ km In relation...

 Open the catalog to page 2

All Optris GmbH & Co. KG catalogs and technical brochures

  1. Infrared Basics

    21  Pages

  2. optris Xi 80

    2  Pages

  3. optris Xi 410

    2  Pages

  4. optris CT 4M

    2  Pages

  5. optris PI 05M

    2  Pages

  6. CSmicro 2M

    2  Pages

  7. optris PI 1M

    2  Pages

  8. optris CT 3M

    2  Pages

  9. optris CT G5

    2  Pages

  10. optris CTfast

    2  Pages

  11. CX hs

    2  Pages

  12. IR-Basics

    40  Pages

  13. PI NetBox

    1  Page

  14. CTlaser P7

    2  Pages

  15. CSlaser G5HF

    2  Pages

  16. CSlaser 2M

    2  Pages

  17. Optris CT P7

    2  Pages

  18. optris CT P3

    2  Pages

  19. optris-CT G5

    2  Pages

  20. CT 3M

    2  Pages

  21. CT 1M 2M

    2  Pages

  22. CThot LT

    2  Pages

  23. CTfast LT

    2  Pages

  24. CT LT

    2  Pages

Archived catalogs

  1. CSmed LT

    2  Pages

  2. optris CX LT

    2  Pages

  3. optris MS LT

    2  Pages

  4. optris CX

    2  Pages

  5. PI 450 G7

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.