CTlaser P7
2Pages

{{requestButtons}}

Catalog excerpts

CTlaser P7 - 1

optris® CTlaser P7 TECHNICAL DATA Non-contact temperature measurement of plastic materials and glass surfaces from 0 °C to 710 °C Features: • ccurate temperature measurement of thin plastic film materials like PET, PU, A PTFE, PA and glass surfaces • Double laser aiming marks real spot location and spot size up from 1.6 mm at any distance • Optics 45:1 with selectable focus, compact sensor head size • Usable up to 85 °C ambient temperature without cooling and automatic laser switch off at 50 °C • Cooling and protection accessories for harsh environmental conditions Measurement specifications Temperature range (scalable via programming keys or software) Spectral range General specifications Optical resolution (90 % energy) System accuracy 2) (at ambient temp. 23 ±5 °C) Repeatability (at ambient temp. 23 ±5 °C) Environmental rating –20 °C ... 85 °C (sensing head, 50 °C with laser ON) –20 °C ... 85 °C (electronics) Storage temperature – 40 °C ... 85 °C (sensing head) –40 °C ... 85 °C (electronics) Relative humidity Vibration (sensor) Temperature resolution (digital) Shock (sensor) 600 g (sensing head) / 420 g (electronics) Emissivity/ Gain (adjustable via programming keys or software) Transmissivity/ Gain (adjustable via programming keys or software) Relay: 2 x 60 V DC/ 42 V ACeff; 0.4 A; optically isolated Peak hold, valley hold, average; extended hold function with threshold and hysteresis USB, RS232, RS485, CAN, Profibus DP, Ethernet (optional) Signal processing (parameter adjustable via programming keys or software, respectively) Software optris® Compact Connect Output impedances mA max. 500 Ω (with 5 – 36 V DC) mV min. 100 kΩ load impedance thermocouple 20 Ω Programmable functional inputs for external emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions) Cable length Power Supply Current draw 1 mW, ON/OFF via electronic box or software Electrical specifications The functioning of the LCD display may be limited in ambient temperatures below 0 °C 2) ε = 1, response time 1 s 3) Whichever is greater 4) With dynamic adaptation at low signal levels 1) Optris GmbH · Ferdinand-Buisson-Str

Open the catalog to page 1
CTlaser P7 - 2

Optical specifications Chart SF optics, D:S = 45:1 Dimensions Sensing head Mounting angle, adjustable in two axes (ACCTLAB) Cooling housing (ACCJCTL) Water cooling and air purge for sensing head (ACCTLW + ACCTLAP) Mounting angle for cooling housing, adjustable in two axes (ACCJAB) Mounting device for cooling housing (ACCTLRM) Specifications are subject to change without notice · CTlaser P7-EN2018-08-A Accessories (examples)

Open the catalog to page 2

All Optris GmbH & Co. KG catalogs and technical brochures

  1. optris Xi 80

    2 Pages

  2. optris CT 4M

    2 Pages

  3. CX hs

    2 Pages

  4. optris CT 3M

    2 Pages

  5. optris CT G5

    2 Pages

  6. IR-Basics

    40 Pages

  7. PI NetBox

    1 Pages

  8. optris PI 1M

    2 Pages

  9. CSlaser G5HF

    2 Pages

  10. CSlaser 2M

    2 Pages

  11. Optris CT P7

    2 Pages

  12. optris CT P3

    2 Pages

  13. optris-CT G5

    2 Pages

  14. CT 3M

    2 Pages

  15. CT 1M 2M

    2 Pages

  16. CThot LT

    2 Pages

  17. CTfast LT

    2 Pages

  18. CSmicro 2M

    2 Pages

  19. optris CX LT

    2 Pages

  20. CT LT

    2 Pages

  21. CSmed LT

    2 Pages

Archived catalogs

  1. optris CX

    2 Pages

  2. optris MS LT

    2 Pages

  3. PI 450 G7

    2 Pages