ATLT6000

ATLT6000

ATLT6000

Product catalog summary
1. Specifications
  • Models: ATLT6000 and ATLT6000Pro
  • Size & Weight: ATLT6000 - 405x510x430 mm (closed), 405x510x660 mm (open), 34Kg; ATLT6000Pro - 425x610x430 mm (closed), 425x610x660 mm (open), 39Kg
  • Cooling: Air cooling with Intelligent Temp Control
  • Spectral Range: ATLT6000 - 185-780 nm; ATLT6000Pro - 180-960 nm
  • Spectral Resolution: 0.10-0.22 nm
  • Elements Analyzed: Si, Ca, Al, Mg, etc.
  • Analysis Time: Adjustable from 1s to 60s
  • Stability (RSD): ATLT6000 ~15%; ATLT6000Pro <10%
  • Voltage & Temperature: AC 220V, 10-40°C, Humidity <60%
2. Usage Precautions
  • Designed for laser-induced breakdown spectroscopy elemental analysis in well logging.
  • Suitable for cuttings and core samples from drilling sites and labs.
  • Not suitable for metals, chemical reagents, or other materials.
  • Element content measured within national standard sample range.
  • Use the provided mold for pressing samples; powder particle size >150 mesh.
  • Default parameter settings should not be modified.
3. Software Interface
  • Includes well parameter setting, element concentration display, sample surface observation, parameter setting, instrument status, and detection start.
4. Sample Preparation
  • Sampling: Minimum 10g sample mass; remove iron filings with a magnet; dry naturally or at 110°C in an oven.
  • Smashing: Use wear-resistant alloy steel hammer; crush at least 10g at a time; clean equipment before and after use; sieve through 150-mesh.
  • Pressing: Use corrosion-resistant stainless steel mold; apply 5 tons pressure for 15s; ensure flat, crack-free surface.
5. Test Results
  • Range: Periodic Table H~U
  • Detection Limit: Non-metallic H~O ≤0.1%, Li, Be, Na ≤0.001%, Mg~Ca ≤0.1%, Sc~Cd ≤0.001%, In~U ≤0.1%.
6. Components
  • Includes laser, lens, plasma, reflector mirror, sample, CCD detector array, and computer.
See more

Catalog excerpts

ATLT6000-1

LIBS_Portable Element Analyzer 1. Parameters Items Size & Weight Laser cooling Spectral Range Spectral Resolution Mineral Elements Analysis Time Stability(RSD) Auto Sample Platform Surface Imaging Working Voltage Working Temp 405x510x430 (screen close) 405x510x660 (screen open) Weight: 34Kg Air cooling 185-780 nm 0.10-0.22 nm Si, Ca, Al, Mg, etc Quantitative Analysis 1s-60s adjustable ~15% Included Included 425x610x430 (screen close) 425x610x660 (screen open) Weight: 39Kg Intelligent Temp Control 180-960 nm 0.10-0.22 nm Si, Ca , Al , Mg, S , etc Quantitative Analysis 1s-60s adjustable <10% Included Included Working Temp: 10-40℃ Working Humidity<60% Working Temp: 10-40℃ Working Humid

 Open the catalog to page 1
ATLT6000-2

2. Precautions for the use of the instrument  This instrument is a special laser-induced breakdown spectroscopy elemental analyzer for well logging.  This instrument is suitable for analyzing cuttings and core samples obtained from drilling sites and laboratories.  This instrument is not suitable for analyzing substances other than the above-mentioned cuttings and cores, such as metals, chemical reagents and other materials.  The content of each element measured by this instrument is within the range of the national standard sample.  To analyze cuttings or cores by pressing cake, it is recommended...

 Open the catalog to page 2
ATLT6000-3

The mass of the cuttings sample is not less than 10g. After the sample was collected, the iron filings in the cuttings were sucked up with a magnet. The cuttings samples are mainly dried by natural drying method. When drying in an oven, the oven temperature should be controlled at 110 °C. Smash 1. The vibrating hammer should be made of wear-resistant alloy steel. 2. The mass of the sample crushed at one time is not less than 10 g. * Matters needing attention: The crushing equipment should be cleaned before and after each use, and sieved through a 150-mesh standard sieve after crushing. The mold...

 Open the catalog to page 3
ATLT6000-4

5. Test Results Range:Periodic Table: H~U Detect limit:Periodic Table : H ~ O (Non-metallic)≤0.1% , Li,Be ,Na≤0.001%, Mg~ Ca≤0.1% , Sc~Cd≤0.00

 Open the catalog to page 4
ATLT6000-6

Reflector mirror Lens Plasma Sample

 Open the catalog to page 6

All Optosky(Xiamen)Photonics Inc. catalogs and technical brochures

  1. GF300

    12  Pages

  2. ATH6500

    30  Pages

  3. ATH5500-17

    21  Pages

  4. ATH1500-17

    22  Pages

  5. ATH1500

    23  Pages

  6. ATH1010

    19  Pages

  7. ATP9100/F

    20  Pages

  8. ATR6600

    10  Pages

  9. ATR6500

    11  Pages

  10. ATR2500-1064

    10  Pages

  11. ATR2500

    4  Pages

  12. ATR6600Pro

    10  Pages

  13. ATP8600

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.