QC-500 One-day Quick Check Laser Calibration System
4Pages

{{requestButtons}}

Catalog excerpts

QC-500 One-day Quick Check Laser Calibration System - 1

Laser Doppler Displacement Meter One-day Quick Check Laser Calibration system

Open the catalog to page 1
QC-500 One-day Quick Check Laser Calibration System - 2

Optodyne's QC-500 compact one-day quick-check laser calibration system is designed to perform machine tool calibration based on the ASME B5.54 standard. The oneday quick-check laser system provides a full comprehensive measurement of linear, volumetric and contouring performance in accordance with the standard and the ISO 9000 requirements. The one-day quick-check system, based on the patented Laser Doppler Displacement Meter (LDDM™) technology, the Vector measurement technique (patent pending) and the Laser/ballbar technique (patent pending), is designed for easy setup and operation. The...

Open the catalog to page 2
QC-500 One-day Quick Check Laser Calibration System - 3

Specifications The QC-500 One-day Quick-check Calibration System features single aperture optical arrangement. Using a flat-mirror as the target, it can perform the "Vector" m easurement to obtain the volumetric positioning e rrors. With the USB interface, it can perform the non-contact circular contouring measurement to obtain the dynamic positioning errors. For a CNC machine with a working volume of 1 cubic meter, both the static volumetric positioning errors and the dynamic circular contouring errors can be measured in one-day. A diagnosis of Circular contour A polar plot of Circular...

Open the catalog to page 3
QC-500 One-day Quick Check Laser Calibration System - 4

QC-500 Configuration Single aperture laser head 0.5" diameter retro-reflector Magnetic base 12 ft. cable set Flat-mirror target 3"x4" (75 x 100 mm) Optical adapter Steering mirror Processor module w/RS-232 interface Windows™ software (SD and LB) Adapter platform Automatic temperature compensation Flat-mirror target 6"(150 mm) Magnetic base and post Capability Laser stability System accuracy Resolution Range Slew rate Volumetric calibration up to 40"x40"x40" (1 cubic meter) Range Measurement 3 displacement errors, 6 straightness errors and 3 squareness errors Accuracy Limited by machine...

Open the catalog to page 4

All OPTODYNE catalogs and technical brochures

  1. LB-500

    4 Pages

  2. LDS-3000

    4 Pages

  3. LICS-200A

    2 Pages

  4. LICS-100A

    2 Pages

  5. LDS-2000

    4 Pages

  6. LDS-1000

    4 Pages

Archived catalogs