OverviewThe document provides technical specifications and usage guidelines for the Optex
non-contact thermometer, specifically the BA series with built-in amplifier. It highlights the features, dimensions, functions, and safety precautions associated with the product.
SpecificationsThe thermometer models include BA-06TV, BA-06TA, BA-30TV, and BA-30TA. Key specifications include:
- Measuring Range: 0 to 500℃
- Field of View: φ6/200mm for BA-06 models and φ30/1000mm for BA-30 models
- Optics: Silicon lens
- Sensing Element: Thermopile/8-14μm
- Response Time: 500ms/90%
- Measuring Accuracy: ±1% of reading value or ±2℃
- Repeatability: ±1℃
- Display Resolution: 1℃
- Analog Output: 1mV/℃ for TV-type and 4-20mA for TA-type
- Emissivity Adjustment: 0.10 to 1.20
- Power Source: DC12-24V±10%
- Environmental Conditions: 0-50℃ ambient temperature, 35-85% RH
- Vibration and Water Resistance: 3G and IP65 respectively
FunctionsThe thermometer features a coaxial laser marker for precise targeting, a digital display for easy reading, and an ε-TEACH function for emissivity adjustment. It supports both voltage and current output types.
Usage and Safety GuidelinesUsers are cautioned against looking directly into the laser or exposing the device to extreme environmental conditions. The thermometer should not be used for medical purposes. Proper voltage must be applied to avoid damage.
Optional AccessoriesAn air purge collar is available to protect the lens from dust and moisture. Black tape (HB-250) can be used for accurate measurement on shiny surfaces.
ApplicationsThe thermometer is suitable for various industrial applications, including temperature control in automotive paint coating, rubber hose production, plastic bottle casting, and paper adhesion processes.
ConclusionThe Optex non-contact thermometer offers precise temperature measurement with user-friendly features, making it suitable for a wide range of industrial applications.