Introduction
This document is the 2021 catalog price list for Oppermann Regelgeräte GmbH, effective from January 1st, 2021. It emphasizes the company's dedication to reliability and innovation in gas and sensor technology, with a focus on products 'Made in Germany'.
Company Overview
Oppermann Regelgeräte GmbH is based in Leinfelden-Echterdingen, Germany. The document includes contact information for key personnel in management, sales, and consulting services.
Catalog Structure
The catalog has been redesigned for better readability, merging previous product groups into a single 'Sensors' category and includes a detailed table of contents for easy navigation.
Product Categories
  • Sensors: Room, HVAC, temperature, and humidity sensors in passive, active, and bus-capable versions.
  • Air Pressure: Differential pressure indicators and transmitters with accessories.
  • Water Pressure: Differential water pressure transmitters and pressure transmitters for water/air.
  • Air Flow: Air flow temperature transmitters and flow sensors, including ATEX-certified options.
  • Water Flow: Flow sensors for water with switching and indicator capabilities.
  • Air Quality: Sensors for monitoring air quality, available in active and bus-capable versions.
  • Safety: Antifreeze monitors, dew point sensors, humidistats, and safety monitoring devices.
Pricing and Terms
Prices are subject to local VAT, with delivery terms ex-works. Payment conditions include a 2% discount for payments within 14 days, and a handling fee for orders below the minimum value.
Gas Warning Devices
Includes OPP-SOR® CO and gas warning systems, with conventional and advanced gas measuring sensors.
Fire Protection
Features duct smoke detectors and fire protection systems for ventilation, with analog and bus technology options.
Reference Projects
Lists various reference projects showcasing the application of Oppermann's sensors in notable buildings and facilities.
Conclusion
The catalog aims to provide comprehensive information on Oppermann's product offerings, enhancing customer experience through a virtual exhibition booth and continuous product availability.
Specifications
  • Transmitter Types: Current (2-wire, 4-20 mA), Voltage (3-wire, 0-10 V / 4-20 mA switchable), Modbus RTU, BACnet MS/TP.
  • Immersion Lengths: 50-150 mm and 200-400 mm.
  • Display Options: Models with or without display; displays not illuminated on 2-wire models.
  • Calibration: 5-point calibration and 10 offset points for output signal adjustment.
  • Measurement Ranges: Humidity 0-500 g/m³, temperature -50 to 100 °C.
  • Supply Voltage: 2-wire 24 V DC, 3-wire/Modbus/BACnet 24 V AC/DC.
  • Output: 2-wire 4-20 mA, 3-wire 0-10 V or 4-20 mA switchable or bus.
  • Error Margins: Humidity ±3% RH at 25 °C for 20-80% RH, Temperature ±0.5 °C for 0-65 °C.
  • Environmental Conditions: -20 to 70 °C, 0-95% RH (non-condensing).
Accessories
  • Sinter Filters: Protect sensors from contamination.
  • Weather Shield: Stainless steel, dimensions 120 x 140 x 75 mm.
  • Clima-sets: Available in straight and angled versions for duct connection.
Additional Features
  • SENSO-X® Highlights: Large display, direct volume flow indication, adjustable working ranges, high measuring accuracy, and NFC parameterization for quick setup.
  • NFC Tool: Allows for parameterization without power draw, reducing initialization time.
CO2 and Temperature Transducers
Various models of CO2 and temperature transducers are available, with or without display, and with Modbus protocol options. Designed for environments with 0 – 95% relative humidity (non-condensing) and have a protection class of IP 65. The CO2 sensor range is 0 – 30,000 ppm, suitable for temperatures between -20 to 50°C.
CO2 Detection System Kit
Designed for local monitoring tasks, includes a central unit with a large display, a CO2 sensor with display, and a strobe with buzzer. Not a substitute for a full gas detection system. Supports a maximum distance of 10m between the central unit and the sensor.
Antifreeze Monitors
Prevent freezing of air heaters with a setting range of -18 to 13°C. Include capillary pipes of varying lengths and are protected to IP 44. Include electric change-over contacts and are supplied with mounting plates and clamps.
Safety Temperature Limiters
Designed for HVAC applications, with a setting range of 90 – 110°C and protected to IP 66. Feature electromechanical safety mechanisms and require manual reset after temperature-triggered shutdowns.
V-belt Monitoring Devices
Monitor the rotation of fans and include LED displays for start-up, operation, and failures. Suitable for various fan sizes with protection classes ranging from IP 40 to IP 67.
Installation Accessories
Various accessories for mounting and installation, including immersion sleeves, wall mounting brackets, spacers, and tension bands. Ensure proper installation and compliance with standards such as EN 14597.
Presence and Brightness Detectors
OPP-PIR-2 and OPP-PIR-LUX-1 presence and brightness detectors designed for ceiling mounting. Feature a 360° detection zone, built-in PIR sensor for motion, and a CdS photocell for brightness detection. Offer adjustable delay and follow-up times, designed for ventilation and air conditioning applications. Maximum installation height is 4.2 meters with a coverage area of 10.5 meters in diameter. Operate within a temperature range of -20 to 60°C and a relative humidity of 0 to 95% (non-condensing).
Room Humidistat
Used for monitoring and controlling relative humidity in rooms, with a measuring range of 30-90% RH. Available with external or internal adjustment options and operates within ambient conditions of -25 to 40°C. Device dimensions are 76 x 76 x 34 mm.
Calibration Protocols
Outlines various factory calibration protocols for differential pressure, relative pressure, temperature, flow, and humidity. Single-point and 3-point calibration protocols are available, with options for custom calibration points. Ensure accurate measurements and are essential for maintaining device performance.
Gas Warning Devices
OPP-SOR® gas warning systems designed for monitoring toxic and flammable gases in various environments, including underground car parks and tunnels. Bus-compatible and can manage up to 240 sensors. Provide optical and acoustic alarms when threshold values are exceeded, ensuring safety by allowing timely evacuation and system shutdowns. TGÜ-BM 3.6 system highlighted for its ability to monitor air quality using multiple gas sensors and is suitable for use in compliance with regulations in Germany, Switzerland, Austria, and the Netherlands.
System Description for TGÜ-BM 3.6
Bus-capable system for monitoring air quality in enclosed spaces. Supports up to 240 sensors and features four alarm zones. Uses a digital bus for communication and includes features like alarm simulation, web interface parameterization, and Modbus connectivity. Requires a 230 V AC power supply and is compatible with uninterruptible power supplies.
Additional Components
Various components such as installation frames, repeaters, and humidity-temperature sensors complement the gas warning systems. Enhance the functionality and efficiency of the systems, providing comprehensive monitoring solutions for different applications.
Specifications
Outlines specifications for gas warning devices and sensors. Key features include floating change-over contacts for alarms, a built-in piezo buzzer, LED displays for operation, and a key switch for alarm suppression during maintenance. Housing dimensions are 200 x 140 x 60 mm with a protection class of IP 65. Devices support up to 10 sensors, expandable to 20 with specific types, and offer multiple language options.
Procedures
Designed for continuous monitoring of air for flammable gases and toxic concentrations. Provide local individual alarms and can be configured via PC software. System includes programmable alarm switching points for pre-alarm and main alarm, with outputs for various relays including pre-alarm, main alarm, and error.
Standards and Norms
Devices adhere to protection class IP 65 and are available in different housing materials such as aluminum and plastic, with protection types ranging from IP 44 to IP 54. Sensors use various measurement principles including electrochemical, infrared, and pellistor techniques.
Recommendations
For critical monitoring tasks, especially in cold storage, infrared sensors with dual-beam technology are recommended due to their accuracy and low cross-sensitivity. Advises checking constraints on sensor types and additional power supply requirements.
Key Data from Tables
Includes a selection table for gas sensors, detailing types, item numbers, and prices. Specifies measuring ranges, installation heights, and applicable gases such as carbon monoxide, nitrogen dioxide, and various refrigerants. Sensors are available in different configurations, including Modbus RS485 options.
Overview
Provides a comprehensive catalog of gas measuring sensors and accessories, valid from January 1st, 2021. Includes specifications, pricing, and installation guidelines for various gas detection devices.
Specifications
Lists sensors for different gases such as Carbon Dioxide (CO2), Carbon Monoxide (CO), Methane (CH4), and others. Each entry includes the MAK value, measuring range, relative gas density, installation height, and pricing. Sensors are designed for high precision and low maintenance, with options for dual-beam IR sensors.
Procedures
Outlines procedures for selecting appropriate sensors based on gas type and environmental conditions. Emphasizes adherence to local regulations and provides guidance on installation heights and densities.
Standards and Recommendations
References DIN standards for warning lights and signs, ensuring compliance with safety regulations. Highlights the importance of regular maintenance and calibration to ensure system reliability.
Accessories
Details a range of accessories, including warning lights, alarm horns, and power supply units. Specifications such as dimensions, power input, and protection class are provided for each accessory.
Key Data from Tables
Tables provide detailed information on sensor types, item numbers, and prices. For example, CO2 sensors are available in various models with different measuring ranges and prices ranging from 1,050 to 1,075 Euros per unit.
Critical Information
Stresses the importance of selecting the correct sensor type for specific gases and conditions. Highlights the need for regular system checks and adherence to safety standards to prevent malfunctions and ensure effective gas detection.
Overview
Provides detailed information on Oppermann's fire protection solutions, specifically focusing on duct smoke detectors and their applications in ventilation systems. Outlines the importance of timely fire detection to prevent the spread of smoke and fire, particularly in buildings with interconnected ventilation systems.
Specifications
Lists various models of KRM and KRM-X duct smoke detectors, detailing their power supply options (230 V AC and 24 V AC/DC), approvals (VdS and DIBt), and features such as RS485 interfaces for Modbus RTU or BACnet connectivity. Specifies the operating temperature range (-20°C to 50°C), protection type (IP 65), and permissible flow velocity (1 – 20 m/s).
Procedures and Standards
References German fire safety requirements (LüAR) and the model policy on fire protection requirements of ventilation systems (M-LüAR). Emphasizes the need for smoke detectors approved by the DIBt for controlling fire and smoke flaps, and VdS-approved detectors for fan control and ventilation monitoring.
Recommendations
Advises using KRM-X types without DIBt certification for monitoring fans and ventilation ducts. Highlights the importance of annual maintenance and the use of testing gas for function tests without disassembly.
Key Features
Includes a feature table for KRM and KRM-X duct smoke detectors, highlighting attributes such as large digital indicators, contamination signals, alarm threshold tracking, and easy assembly and installation. Mentions the availability of accessories like TurboTube air duct sensor tubes and spraywater-protected housings.
Conclusion
Oppermann's duct smoke detectors are designed to meet stringent fire protection standards, offering reliable solutions for various building types and ventilation systems. Underscores the importance of adhering to local regulations and maintaining the equipment for optimal performance.
Specifications
Outlines the specifications for duct smoke detectors, including operating current (120 mA), operating temperature range (-20°C to 50°C), protection type (IP 65), and permissible flow velocity (1 – 20 m/s). Dimensions are approximately 271 x 172 x 85 mm, with cable glands of 3 x M16. Detectors are compatible with Modbus and BACnet protocols.
Certifications and Approvals
Detectors have DIBt certification and VdS approval, complying with DIN EN 54-27 standards. DIBt certification is specifically for controlling fire and smoke protection flaps.
Product Features
Detectors use the scattered light principle for smoke detection and feature alarm threshold tracking for extended service life. Provide continuous contamination level indication and have a smoke alarm relay with floating changeover contact. Equipped with an RS485 interface for automation station connections.
Accessories and Modules
Lists various accessories, including flap modules, power supply units, display units, and mounting brackets. Flap module designed for use with bus-capable KRM and KRM-X models, featuring multiple inputs and outputs for system integration.
Installation and Usage
Detectors are suitable for use in air ducts for early detection of smoldering fires and smoke. Designed to be compatible with various duct sizes and can be used with additional modules for enhanced functionality.
Pricing and Availability
Includes a catalog price list for 2021, detailing the prices for different models and accessories. Product availability is scheduled for Q1 2021.
Overview
Catalog price list for fire protection equipment, specifically focusing on smoke detectors, manual call points, and related control devices. Includes technical specifications, pricing, and product details for various models.
Specifications
  • Optical Smoke Detectors: Designed for early detection of smoldering fires using the scattered light principle. Include mounting bases and feature LEDs for contamination and alarm indication. Operating temperature ranges from -10 to 50°C, with VdS test certification.
  • Thermodifferential Alarms: Ceiling-mounted detectors that respond to rapid temperature increases or fixed temperature limits. Suitable for environments where smoke detectors may trigger false alarms. Operating temperature ranges from -20 to 90°C.
  • Manual Call Points: Available in various colors with resistors for cable monitoring. Feature a replaceable glass pane and LED indicators for operation status and errors. Operating temperature ranges from -20 to 60°C.
Procedures
  • Installation includes mounting bases for all detectors and alarms.
  • Controllers are used for signal evaluation and power supply, supporting up to 30 analog smoke sensors or manual alarms.
Standards and Certifications
  • Products comply with EN 54 standards and hold VdS test certificates.
  • Temperature and environmental specifications are provided for each product to ensure proper operation within specified ranges.
Recommendations
  • Use the ABAV-S control device for power monitoring and signal evaluation.
  • Consider environmental conditions when selecting between smoke detectors and thermodifferential alarms to avoid false alarms.
Key Data
  • Alarm current consumption for smoke detectors is typically 40 mA, while thermodifferential alarms consume 52 mA at 24 V DC.
  • Manual call points are available with optional IP54 protection for outdoor use.
Additional Information Includes a type index and general conditions of sale, emphasizing adherence to local rules and regulations. Contact information for Oppermann Regelgeräte GmbH is provided for further inquiries.
See more

Catalog excerpts

Oppermann Regelgeräte GmbH Catalogue 2021-1

CATALOG PRICE LIST 2021 Reliability and Innovation “Made in Germany”

 Open the catalog to page 1
Oppermann Regelgeräte GmbH Catalogue 2021-2

[email protected] www.oprg.de Oppermann Regelgerate GmbH Phone +49 711 727235-60 Im Spitzhau 1, D-70771 Leinfelden-Echterdingen, Germany Fax +49 711 7280527 Heike Dirmeier Phone +49 711 727235-76 [email protected] Internal sales management Niklas Hain Phone +49 711 727235-888 [email protected] Gas/CO warning devices Yvonne Heidorn Phone +49 711 727235-69 [email protected] Raik Lehnacker Phone +49 711 727235-64 [email protected] Ruben Egeler Phone +49 711 727235-810 [email protected] External sales management Matthias Fricke Mobile +49 170 9053726 [email protected] External sales service Planning consulting service/...

 Open the catalog to page 2
Oppermann Regelgeräte GmbH Catalogue 2021-3

Catalog price list 2021 Dear Business Partners and Customers, Our new short catalog is out, and I am happy to be able to introduce you to it here. Our aim in compiling this catalog was to optimize its reader friendliness and make it easier for you to find the products you are looking for. For this reason we have redesigned the short catalog. We have combined the two former product groups “Sensors PG1 – Heating, Ventilation and Air Conditioning” and “Sensors PG2 – Temperature and Humidity Sensors” into a single product group named “Sensors” and reorganized it in the process. The entirely reorganized...

 Open the catalog to page 3
Oppermann Regelgeräte GmbH Catalogue 2021-4

Catalog price list 2021 Table of contents Sensors OPP-SENS® SENSO-X® room sensors/HVAC sensors OPP-SENS® type designations 15 Accessories for immersion temperature sensors 21 Accessories for weather protection only 37 Air duct temperature sensors 28 Air duct average temperature sensors 26 Cable temperature sensors 29 Contact temperature sensors 30 External temperature sensors 36 Immersion temperature sensors 18 Accessories for immersion temperature sensors 21 Air duct average temperature sensors 27 Contact temperature sensors 32 External temperature sensors 34 Immersion temperature transmitters...

 Open the catalog to page 4
Oppermann Regelgeräte GmbH Catalogue 2021-5

Sensors OPP-SENS® SENSO-X® room sensors/HVAC sensors OPP-SENS® type designations 15 Volume flow Accessories for differential air pressure volume flow transmitters 55 Differential air pressure volume flow transmitters 53 Volume flow temperature transmitters 72 Volume flow indicator-transmitters 74 Accessories for differential air pressure volume flow transmitters 55 Differential air pressure volume flow transmitters 53 Volume flow temperature transmitters 72 Volume flow indicator-transmitters 74 Accessories for air flow sensors Air flow temperature transmitters Flow sensors air 82 Air flow temperature...

 Open the catalog to page 5
Oppermann Regelgeräte GmbH Catalogue 2021-6

Catalog price list 2021 Table of contents Sensors OPP-ROOM® Room sensors OPP-ROOM® type designations 100 Room temperature sensors (passive) 101 Room temperature controller 106 Room temperature sensors (active) optionally with occupancy + LUX brightness sensor 104 Room temperature controller 106 Room temperature sensors (active) optionally with occupancy + LUX brightness sensor 104 Room humidity sensors 107 Room humidity-temperature sensors optionally with occupancy + LUX brightness sensor 108 Room humidity-temperature sensors optionally with occupancy + LUX brightness sensor 108 active bus-capable...

 Open the catalog to page 6
Oppermann Regelgeräte GmbH Catalogue 2021-7

Catalog price list 2021 Table of contents OPP-SOR® CO warning systems/gas warning systems OPP-SOR® type designations 124 Car parks and tunnels OPP-SOR® CO warning devices for car parks and tunnels 118 OPP-SOR® Gas measuring sensors 122 Conventional gas measuring sensors 123 Gas measuring sensor selection table 125 OPP-SOR® Gas measuring sensors 122 OPP-SOR® Gas warning systems 121 Power supply units 133 Services for gas and CO warning devices 135 Transparent warning lights 129 Fire protection Duct smoke detector KRM( OPP-PRO® type designations 140 Feature table for KRM®/KRM-X® duct smoke detector...

 Open the catalog to page 7
Oppermann Regelgeräte GmbH Catalogue 2021-8

Reference list for sensors The corporate headquarters of Thales Deutschland GmbH in Ditzingen was completed in 2014. The Modbus-interface allowed the OPP-SENS® sensors from Oppermann to be seamlessly integrated into the DDC automation systems from Schneider and Wago. Audi AG Ingolstadt Audi Neubau Ingolstadt ”Gebäude H6“ Auswärtiges Amt Berlin BASF Rheinufer Süd Ludwigshafen BMW Regensburg und München CPA Forschungsgebäude TUM Garching Daimler AG Esslingen-Mettingen Daimler AG Untertürkheim Das GERBER Stuttgart Ernst Strüngmann Institute Frankfurt / Main Flughafen Frankfurt / Main Flughafen München...

 Open the catalog to page 8
Oppermann Regelgeräte GmbH Catalogue 2021-9

© Aldinger + Wolf © Aldinger + Wolf Intelligent bus-compatible OPP-SENS® Modbus sensors from Oppermann control the air-conditioning systems at GERBER in Stuttgart. The GERBER shopping center opened its doors on September 23, 2014. Approximately 113,000 spectators attended the grand opening. About 25,000 square meters of retail space, 86 stores and restaurants are distributed over three levels and a shopping window front that stretches for almost one kilometer: this is the GERBER shopping center in the center of Stuttgart city. About 25,000 shoppers are expected to come and go on a daily basis....

 Open the catalog to page 9
Oppermann Regelgeräte GmbH Catalogue 2021-10

Reference list for gas and CO warning devices The Sedelhöfe is an architecturally open urban quarter for shopping, living and working in the city center of Ulm. It has an underground garage offering space for 700 vehicles and is equipped with 6 TGÜ-KM 3.6 and 57 GMF CO sensors from Oppermann for monitoring air quality. © Aurelis Real Estate BayWa AG München Bildungscampus Freiham Bremer Landesbank Hamburg Daimler AG Stuttgart Daimler Leinfelden Echterdingen Daimler Office V Eurotower Frankfurt / Main Flughafen München Fraport Frankfurt / Main Garching Galileo Garching Neue Mitte am Hochschulcampus...

 Open the catalog to page 10
Oppermann Regelgeräte GmbH Catalogue 2021-11

Bus-compatible Oppermann CO alarm systems of type OPP-SOR® ensure the safety of 35 million air passengers annually in the parking garages at the Munich airport on a surface of 35 football pitches. Catalog price list 2021  |  Reference list  |  Valid as of January 1st, 202

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.