P920 Beam Profiling Camera
1 / 1Pages

Catalog excerpts

P920 Beam Profiling Camera - 1

3.3.4.1.2 GigE/USB Silicon CCD Cameras SP920G, SP920 high resolution SP920G • 1/1.8” imager format • Interface: - GigE: SP920G - USB: SP920 • Small camera size: SP920 • >60dB true dynamic resolution Application Spectral response (2) Active area Beam sizes Pixel spacing Number of effective pixels Minimum system dynamic range Linearity with power Accuracy of beam width Frame rates in 12 bit mode (4) Shutter duration Gain control Trigger Photodiode trigger Saturation intensity (1) Lowest measurable signal (1) Damage threshold (3) Dimensions CCD recess Image quality at 1064nm 1/1.8” format 1/1.8” format 190 - 1100nm 190 - 1100nm 7.1mm x 5.3mm 7.1mm x 5.3mm 44μm - 5.3mm 44μm - 5.3mm 4.4μm 4.4μm 1624 x 1224 1624 x 1224 61 dB 60 dB ±1% ±1% ±2% ±2% 14 fps at full resolution 15 fps at full resolution 30μs to multiple frames 30μs to multiple frames 0 dB to 24 dB 0 dB to 24 dB Hardware/Software trigger & strobe out Hardware/Software trigger & strobe out Si response: SP90408 Si response: SP90408 2 0.97µW/cm 0.97µW/cm2 2 1.2nW/cm 1.2nW/cm2 50W/cm2 / 0.1J/cm2 with all filters installed for < 100ns pulse width 44 mm x 29 mm x 58 mm 29 mm x 29 mm x 30 mm 17.5 mm 12.5 mm Pulsed with trigger sync - excellent Pulsed with trigger sync - excellent Pulsed with video trigger - good Pulsed with video trigger - good CW - good CW - good Interline transfer CCD Interline transfer CCD GigE USB 3.0 Windows 7 (64) and Windows 10 Operation mode PC interface OS supported Ordering Information Supported software BeamGage Professional BeamGage Standard (1) Camera set to full resolution at maximum frame rate and exposure times, running CW at 633nm wavelength. Camera set to minimum useful gain for saturation test and maximum useful gain for lowest signal test. (2) The camera’s natural response is from 350nm through 1100nm. To measure effectively below 350nm, please make use of one of our UV converters. Otherwise the sensitivity is too low and the measurement accuracy may degrade. (3) This is the damage threshold of the filter glass of the filters. Assuming all filters mounted with ND1 (red housing) filter in the front. Distortion of the beam may occur with average power densities as low as 5W/cm2. (4) Highly dependent on PC processor and graphics adapter performance. (5) Comes with GigE cable, Power with Trigger cable and 3 ND filters. (6) Comes with USB 3.0 cable, Trigger cable and 3 ND filters. Beam Analysis ACTIVE AREA GIGABIT ETHERNET CONNECTOR GPIO CONNECTOR JANUARY 1, 2020 FOR LATEST UPDATES, PLEASE VISIT WWW.OPHIR

Open the catalog to page 1

All Ophir Optronics catalogs and technical brochures

  1. SP932U

    1 Pages

  2. ConoPoint-3

    2 Pages

  3. nova catalog

    2 Pages

  4. vega catalog

    2 Pages

  5. BeamWatchAM

    2 Pages

  6. StarBright

    2 Pages

  7. 680274

    1 Pages

  8. StarLite

    2 Pages

  9. M200s

    3 Pages

  10. NanoScan 2s

    14 Pages

  11. BeamWatch®

    5 Pages

  12. ModeCheck ®

    3 Pages

  13. Nova

    2 Pages

  14. Power Pucks

    1 Pages

  15. StarBrigh

    2 Pages

  16. Orion

    2 Pages

  17. Laserstar

    2 Pages

  18. RP Sensors

    2 Pages

Archived catalogs